Mechanical Strength and Rheological Properties of Tissue Adhesives With Regard to Colorectal Anastomosis An Ex Vivo Study

被引:75
|
作者
Vakalopoulos, Konstantinos Aristotelis [1 ]
Wu, Zhouqiao [1 ]
Kroese, Leonard [1 ]
Kleinrensink, Gert-Jan [2 ]
Jeekel, Johannes [2 ]
Vendamme, Richard [3 ]
Dodou, Dimitra [4 ]
Lange, Johan Frederik [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Surg, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Neurosci, NL-3000 CA Rotterdam, Netherlands
[3] Nitto Europe NV, European Res Comm, Genk, Belgium
[4] Delft Univ Technol, Delft, Netherlands
关键词
anastomotic leakage; colorectal surgery; surgical glue; tissue adhesives; SURGICAL ADHESIVE; SEALANTS; SURGERY; GLUE; BIOGLUE;
D O I
10.1097/SLA.0000000000000599
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To compare mechanical strength and rheology of existing tissue adhesives in a clinically relevant test setup with regard to colorectal anastomosis. Background: Little is known on the mechanical strength of tissue adhesives directly after application. Furthermore, rheological profiling may be important in understanding mechanical performance and explaining differences between adhesives. This study provides new data on the mechanical strength and rheology of a comprehensive list of tissue adhesives with regard to colorectal adhesiveness. Methods: Twelve surgical tissue adhesives were included: 4 cyanoacrylate adhesives (CA), 2 fibrin glues (FG), 3 polyethylene glycol (PEG) adhesives, and 3 albumin-based (AB) adhesives. Tubular rat colonic segments were glued together. Tensile (T), shear (S), and peel (P) strength were measured. Shear storage (G') and shear loss (G '') moduli were also evaluated. Results: CA adhesives were stronger than AB (T: P = 0.017; S: P = 0.064; P: P < 0.001), which, in turn, were stronger than PEG (T: P < 0.001; S: P < 0.001; P: P = 0.018). PEG were stronger than FG for shear (P = 0.013) and comparable for tensile and peel strength (P > 0.05). Within-group variation was smallest for CA. Mechanical strength correlated strongly between performed tests. Rheological properties (G' and G '') correlated strongly with mechanical strength for all adhesives combined. Conclusions: CA adhesives are the strongest and most homogenous group in terms of mechanical strength. Hydrogels (FG, AB) are heterogeneous, with lower mechanical strength than CA. FG are mechanically the weakest adhesives. Rheological profiles correlate to mechanical strength and may be useful for predicting mechanical performance.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 50 条
  • [41] In Vivo Study of Wound Bursting Strength and Compliance of Topical Skin Adhesives
    Singer, Adam J.
    Perry, Larry C.
    Allen, Robert L., Jr.
    ACADEMIC EMERGENCY MEDICINE, 2008, 15 (12) : 1290 - 1294
  • [42] The in vivo Mechanical Properties of Muscular Bulk Tissue
    Aritan, Serdar
    Oyadiji, S. Olutunde
    Bartlett, Roger M.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5259 - +
  • [43] Measurement of the hyperelastic properties of ex vivo brain tissue slices
    Kaster, T.
    Sack, I.
    Samani, A.
    JOURNAL OF BIOMECHANICS, 2011, 44 (06) : 1158 - 1163
  • [44] Ex Vivo Optical Properties Estimation for Reliable Tissue Characterization
    Solouma, Nahed
    Hamdy, Omnia
    PHOTONICS, 2023, 10 (08)
  • [45] Ex vivo Methods for Measuring Cardiac Muscle Mechanical Properties
    Knight, Walter E.
    Ali, Hadi R.
    Nakano, Stephanie J.
    Wilson, Cortney E.
    Walker, Lori A.
    Woulfe, Kathleen C.
    FRONTIERS IN PHYSIOLOGY, 2021, 11
  • [46] Ex vivo surface and mechanical properties of coated orthodontic archwires
    Elayyan, Firas
    Silikas, Nick
    Bearn, David
    EUROPEAN JOURNAL OF ORTHODONTICS, 2008, 30 (06) : 661 - 667
  • [47] Design of a force-measuring setup for colorectal compression anastomosis and first ex-vivo results
    Jana Steger
    Isabella Patzke
    Maximilian Berlet
    Stefanie Ficht
    Markus Eblenkamp
    Petra Mela
    Dirk Wilhelm
    International Journal of Computer Assisted Radiology and Surgery, 2021, 16 : 1335 - 1345
  • [48] Design of a force-measuring setup for colorectal compression anastomosis and first ex-vivo results
    Steger, Jana
    Patzke, Isabella
    Berlet, Maximilian
    Ficht, Stefanie
    Eblenkamp, Markus
    Mela, Petra
    Wilhelm, Dirk
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2021, 16 (08) : 1335 - 1345
  • [49] Ex vivo biomechanical evaluation of tissue construct strength in an equine colopexy model
    Gaitan, Hannah M.
    Mudge, Margaret C.
    Litsky, Alan S.
    Arruda, Andreia G.
    Gardner, Alison K.
    VETERINARY SURGERY, 2024,
  • [50] Suture Dehiscence in the Tricuspid Annulus: An Ex Vivo Analysis of Tissue Strength and Composition
    Paul, Deborah M.
    Naran, Ajay
    Pierce, Eric L.
    Bloodworth, Charles H.
    Bolling, Steven F.
    Yoganathan, Ajit P.
    ANNALS OF THORACIC SURGERY, 2017, 104 (03): : 820 - 826