Mechanical Strength and Rheological Properties of Tissue Adhesives With Regard to Colorectal Anastomosis An Ex Vivo Study

被引:75
|
作者
Vakalopoulos, Konstantinos Aristotelis [1 ]
Wu, Zhouqiao [1 ]
Kroese, Leonard [1 ]
Kleinrensink, Gert-Jan [2 ]
Jeekel, Johannes [2 ]
Vendamme, Richard [3 ]
Dodou, Dimitra [4 ]
Lange, Johan Frederik [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Surg, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Neurosci, NL-3000 CA Rotterdam, Netherlands
[3] Nitto Europe NV, European Res Comm, Genk, Belgium
[4] Delft Univ Technol, Delft, Netherlands
关键词
anastomotic leakage; colorectal surgery; surgical glue; tissue adhesives; SURGICAL ADHESIVE; SEALANTS; SURGERY; GLUE; BIOGLUE;
D O I
10.1097/SLA.0000000000000599
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To compare mechanical strength and rheology of existing tissue adhesives in a clinically relevant test setup with regard to colorectal anastomosis. Background: Little is known on the mechanical strength of tissue adhesives directly after application. Furthermore, rheological profiling may be important in understanding mechanical performance and explaining differences between adhesives. This study provides new data on the mechanical strength and rheology of a comprehensive list of tissue adhesives with regard to colorectal adhesiveness. Methods: Twelve surgical tissue adhesives were included: 4 cyanoacrylate adhesives (CA), 2 fibrin glues (FG), 3 polyethylene glycol (PEG) adhesives, and 3 albumin-based (AB) adhesives. Tubular rat colonic segments were glued together. Tensile (T), shear (S), and peel (P) strength were measured. Shear storage (G') and shear loss (G '') moduli were also evaluated. Results: CA adhesives were stronger than AB (T: P = 0.017; S: P = 0.064; P: P < 0.001), which, in turn, were stronger than PEG (T: P < 0.001; S: P < 0.001; P: P = 0.018). PEG were stronger than FG for shear (P = 0.013) and comparable for tensile and peel strength (P > 0.05). Within-group variation was smallest for CA. Mechanical strength correlated strongly between performed tests. Rheological properties (G' and G '') correlated strongly with mechanical strength for all adhesives combined. Conclusions: CA adhesives are the strongest and most homogenous group in terms of mechanical strength. Hydrogels (FG, AB) are heterogeneous, with lower mechanical strength than CA. FG are mechanically the weakest adhesives. Rheological profiles correlate to mechanical strength and may be useful for predicting mechanical performance.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 50 条
  • [21] Mechanical factors in the prediction of integrity of the gastrojejunal anastomosis in ex-vivo RYGB models
    Sahloul, Mohamed
    McKay, Siobhan C.
    Phelan, Liam
    Ludwig, Christian
    Mahawar, Kamal
    Singhal, Rishi
    SURGERY FOR OBESITY AND RELATED DISEASES, 2019, 15 (06) : 887 - 893
  • [22] Modulation of mechanical properties in multiple-component tissue adhesives
    Sierra, D.H., 2000, John Wiley and Sons Inc. (52):
  • [23] The Feasibility of LigaSure to Create Intestinal Anastomosis: Results of Ex Vivo Study
    Santini, Mario
    Fiorelli, Alfonso
    Messina, Gaetana
    Mazzella, Antonio
    Accardo, Marina
    SURGICAL INNOVATION, 2015, 22 (03) : 266 - 273
  • [24] Releasing tension on a tracheal anastomosis: An ex vivo study on a sheep model
    Zaugg, Y
    Cuffel, C
    Monnier, P
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2006, 115 (05): : 398 - 402
  • [25] Study on rheological mechanical properties of Sandstone
    Jiang, Yuzhou
    Wang, Ruihong
    2011 AASRI CONFERENCE ON APPLIED INFORMATION TECHNOLOGY (AASRI-AIT 2011), VOL 3, 2011, : 43 - 46
  • [26] Study on rheological mechanical properties of Sandstone
    Jiang, Yuzhou
    Wang, Ruihong
    2011 INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS AND NEURAL COMPUTING (FSNC 2011), VOL V, 2011, : 43 - 46
  • [27] A Novel Experimental Approach for the Measurement of Vibration-Induced Changes in the Rheological Properties of Ex Vivo Ovine Brain Tissue
    Lilley, Rebecca L.
    Kabaliuk, Natalia
    Reynaud, Antoine
    Devananthan, Pavithran
    Smith, Nicole
    Docherty, Paul D.
    SENSORS, 2024, 24 (07)
  • [28] THE DIELECTRIC PROPERTIES OF UPPER GASTROINTESTINAL TISSUE TYPES - AN EX-VIVO FEASIBILITY STUDY
    Samaddar, Poulami
    Steinfort, Luz Maria Neira
    Fetzer, Jeffrey
    Arunachalam, Shivaram Poigai
    Wang, Kenneth K.
    Leggett, Cadman L.
    GASTROENTEROLOGY, 2022, 162 (07) : S1026 - S1026
  • [29] Mechanical properties and tissue damage caused by staples in gastrointestinal anastomosis
    Dai, Xuan
    Zheng, Junjie
    Yu, Xiaoli
    Liu, Zhihua
    Zheng, Lijuan
    Chen, Zhihua
    Wang, Chengyong
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2024, 238 (01) : 33 - 44
  • [30] Longitudinal study of the mechanical properties of rat abdominal aortas incubated in ex vivo conditions
    Sugita S.
    Kawai H.
    Ujihara Y.
    Nakamura M.
    Journal of Biorheology, 2023, 37 (02) : 36 - 43