Development of a Magnetic Attachment Method for Bionic Eye Applications

被引:7
|
作者
Fox, Kate [1 ,3 ]
Meffin, Hamish [2 ,4 ]
Burns, Owen [5 ]
Abbott, Carla J. [6 ]
Allen, Penelope J. [6 ]
Opie, Nicholas L. [6 ]
McGowan, Ceara [5 ]
Yeoh, Jonathan [6 ]
Ahnood, Arman [1 ]
Luu, Chi D. [6 ]
Cicione, Rosemary [1 ]
Saunders, Alexia L. [5 ]
McPhedran, Michelle [5 ]
Cardamone, Lisa [5 ]
Villalobos, Joel [5 ]
Garrett, David J. [1 ,5 ]
Nayagam, David A. X. [5 ]
Apollo, Nicholas V. [1 ,5 ]
Ganesan, Kumaravelu [1 ]
Shivdasani, Mohit N. [5 ]
Stacey, Alastair [1 ]
Escudie, Mathilde [1 ]
Lichter, Samantha [1 ]
Shepherd, Robert K. [5 ]
Prawer, Steven [1 ]
机构
[1] Univ Melbourne, Sch Phys, Melbourne, Vic, Australia
[2] Univ Melbourne, Dept Elect & Elect Engn, Melbourne, Vic, Australia
[3] RMIT Univ, Sch Aerosp Mech & Mfg Engn, Melbourne, Vic, Australia
[4] Australian Coll Optometry, Natl Vis Res Inst, Melbourne, Vic, Australia
[5] Bion Inst, Melbourne, Vic, Australia
[6] Royal Victorian Eye & Ear Hosp, Ctr Eye Res Australia, Melbourne, Vic 3002, Australia
基金
澳大利亚国家健康与医学研究理事会; 澳大利亚研究理事会;
关键词
Magnet; Bionic eye; Attachment; Retina; SUPRACHOROIDAL RETINAL PROSTHESIS; NDFEB PERMANENT-MAGNETS; CORROSION BEHAVIOR; BIOMEDICAL IMPLANTS; ACID-SOLUTIONS; IN-VIVO; STIMULATION; DIAMOND; ADHESIVE; COATINGS;
D O I
10.1111/aor.12582
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Successful visual prostheses require stable, long-term attachment. Epiretinal prostheses, in particular, require attachment methods to fix the prosthesis onto the retina. The most common method is fixation with a retinal tack; however, tacks cause retinal trauma, and surgical proficiency is important to ensure optimal placement of the prosthesis near the macula. Accordingly, alternate attachment methods are required. In this study, we detail a novel method of magnetic attachment for an epiretinal prosthesis using two prostheses components positioned on opposing sides of the retina. The magnetic attachment technique was piloted in a feline animal model (chronic, nonrecovery implantation). We also detail a new method to reliably control the magnet coupling force using heat. It was found that the force exerted upon the tissue that separates the two components could be minimized as the measured force is proportionately smaller at the working distance. We thus detail, for the first time, a surgical method using customized magnets to position and affix an epiretinal prosthesis on the retina. The position of the epiretinal prosthesis is reliable, and its location on the retina is accurately controlled by the placement of a secondary magnet in the suprachoroidal location. The electrode position above the retina is less than 50 microns at the center of the device, although there were pressure points seen at the two edges due to curvature misalignment. The degree of retinal compression found in this study was unacceptably high; nevertheless, the normal structure of the retina remained intact under the electrodes.
引用
收藏
页码:E12 / E24
页数:13
相关论文
共 50 条
  • [31] Advanced Bionic Attachment Equipment Inspired by the Attachment Performance of Aquatic Organisms: A Review
    Zhang, Dexue
    Xu, Jin
    Liu, Xuefeng
    Zhang, Qifeng
    Cong, Qian
    Chen, Tingkun
    Liu, Chaozong
    BIOMIMETICS, 2023, 8 (01)
  • [32] Object tracking based on the improved particle filter method using on the bionic eye PTZ
    Luo, Jun
    Hu, Juqi
    Li, Hengyu
    Liu, Hengli
    Wang, Hao
    Xie, Shaorong
    Gu, Jason
    2013 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2013, : 2213 - 2218
  • [33] Development of an implantable bionic for dynamic eye closure in facial nerve paralysis: Evolution of the design
    Hasmat, Shaheen
    Lovell, Nigel H.
    Low, Tsu-Hui
    Clark, Jonathan R.
    MEDICAL ENGINEERING & PHYSICS, 2023, 115
  • [34] Development of Robot Bionic Eye with Spherical Parallel Manipulator Based on Oculomotor Control Model
    Li, Hengyu
    Luo, Jun
    Chen, Jinbo
    Liu, Zhixiang
    Xie, Shaorong
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (1B): : 1 - 7
  • [35] Development of ion attachment mass spectrometry and its applications
    Shiokawa, Y
    Nakamura, M
    Maruyama, H
    Hirano, Y
    Taneda, Y
    Inoue, M
    Fujii, T
    BUNSEKI KAGAKU, 2004, 53 (06) : 475 - 489
  • [36] A differential magnetic localization method for bionic micro-machine guided by external magnetic field
    Wang Zhe
    Song Tao
    Wang Jinguang
    Wang Zheng
    Yang Cenyu
    2008 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS, VOLS 1-4, 2009, : 997 - 1001
  • [37] Design and Analysis of a Bionic Attachment Module for Complex Surfaces
    Lu, Yi
    Wu, Hongmin
    Liao, Zhaoyang
    Bi, Qilin
    Xu, Zhihao
    Zhou, Xuefeng
    Guan, Yisheng
    Gu, Shichao
    2024 IEEE 19TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, ICIEA 2024, 2024,
  • [38] Optimal design of a parallel bionic eye mechanism
    Yuanhao Cheng
    Sun’an Wang
    Dehong Yu
    Journal of Mechanical Science and Technology, 2019, 33 : 879 - 887
  • [39] Building the bionic eye: an emerging reality and opportunity
    Merabet, Lotfi B.
    ENHANCING PERFORMANCE FOR ACTION AND PERCEPTION: MULTISENSORY INTEGRATION, NEUROPLASTICITY AND NEUROPROSTHETICS, PT II, 2011, 192 : 3 - 15
  • [40] "Bionic Eye" May Help Reverse Blindness
    Kelly Young
    滕旭宁