Development of a Magnetic Attachment Method for Bionic Eye Applications

被引:7
|
作者
Fox, Kate [1 ,3 ]
Meffin, Hamish [2 ,4 ]
Burns, Owen [5 ]
Abbott, Carla J. [6 ]
Allen, Penelope J. [6 ]
Opie, Nicholas L. [6 ]
McGowan, Ceara [5 ]
Yeoh, Jonathan [6 ]
Ahnood, Arman [1 ]
Luu, Chi D. [6 ]
Cicione, Rosemary [1 ]
Saunders, Alexia L. [5 ]
McPhedran, Michelle [5 ]
Cardamone, Lisa [5 ]
Villalobos, Joel [5 ]
Garrett, David J. [1 ,5 ]
Nayagam, David A. X. [5 ]
Apollo, Nicholas V. [1 ,5 ]
Ganesan, Kumaravelu [1 ]
Shivdasani, Mohit N. [5 ]
Stacey, Alastair [1 ]
Escudie, Mathilde [1 ]
Lichter, Samantha [1 ]
Shepherd, Robert K. [5 ]
Prawer, Steven [1 ]
机构
[1] Univ Melbourne, Sch Phys, Melbourne, Vic, Australia
[2] Univ Melbourne, Dept Elect & Elect Engn, Melbourne, Vic, Australia
[3] RMIT Univ, Sch Aerosp Mech & Mfg Engn, Melbourne, Vic, Australia
[4] Australian Coll Optometry, Natl Vis Res Inst, Melbourne, Vic, Australia
[5] Bion Inst, Melbourne, Vic, Australia
[6] Royal Victorian Eye & Ear Hosp, Ctr Eye Res Australia, Melbourne, Vic 3002, Australia
基金
澳大利亚国家健康与医学研究理事会; 澳大利亚研究理事会;
关键词
Magnet; Bionic eye; Attachment; Retina; SUPRACHOROIDAL RETINAL PROSTHESIS; NDFEB PERMANENT-MAGNETS; CORROSION BEHAVIOR; BIOMEDICAL IMPLANTS; ACID-SOLUTIONS; IN-VIVO; STIMULATION; DIAMOND; ADHESIVE; COATINGS;
D O I
10.1111/aor.12582
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Successful visual prostheses require stable, long-term attachment. Epiretinal prostheses, in particular, require attachment methods to fix the prosthesis onto the retina. The most common method is fixation with a retinal tack; however, tacks cause retinal trauma, and surgical proficiency is important to ensure optimal placement of the prosthesis near the macula. Accordingly, alternate attachment methods are required. In this study, we detail a novel method of magnetic attachment for an epiretinal prosthesis using two prostheses components positioned on opposing sides of the retina. The magnetic attachment technique was piloted in a feline animal model (chronic, nonrecovery implantation). We also detail a new method to reliably control the magnet coupling force using heat. It was found that the force exerted upon the tissue that separates the two components could be minimized as the measured force is proportionately smaller at the working distance. We thus detail, for the first time, a surgical method using customized magnets to position and affix an epiretinal prosthesis on the retina. The position of the epiretinal prosthesis is reliable, and its location on the retina is accurately controlled by the placement of a secondary magnet in the suprachoroidal location. The electrode position above the retina is less than 50 microns at the center of the device, although there were pressure points seen at the two edges due to curvature misalignment. The degree of retinal compression found in this study was unacceptably high; nevertheless, the normal structure of the retina remained intact under the electrodes.
引用
收藏
页码:E12 / E24
页数:13
相关论文
共 50 条
  • [21] Design of the bionic compound eye optical system based on field splicing method
    School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun
    130022, China
    Yi Qi Yi Biao Xue Bao, 2 (422-429):
  • [22] An Integrated Two-Pose Calibration Method for Estimating Head-Eye Parameters of a Robotic Bionic Eye
    Chen, Xiaopeng
    Wang, Changjin
    Zhang, Weizhong
    Lan, Kunyan
    Huang, Qiang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (04) : 1664 - 1672
  • [23] THE CHALLENGE AND THE PROMISE OF THE BIONIC EYE. THE BIONIC VISION AUSTRALIA PROJECT
    Guymer, Robyn
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 : 123 - 124
  • [24] ATTACHMENT OF DNA AND OLIGONUCLEOTIDES TO MAGNETIC PARTICLES - METHODS AND APPLICATIONS
    RICKWOOD, D
    LUND, V
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 330 (4-5): : 330 - 330
  • [25] Bionic Eye and Advanced Technology in Ophthalmology
    Niyazoglu, Gamze
    Ataseven, Gulsen
    Eltutar, Kadir
    ISTANBUL MEDICAL JOURNAL, 2011, 12 (02): : 79 - 84
  • [26] Design of a Bionic Eye Experimental Platform
    Zeng, Xianwu
    Zhang, Menghua
    Ma, Xin
    Li, Yibin
    2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 137 - 141
  • [27] On Just Noticeable Difference for Bionic Eye
    Li, Yi
    McCarthy, Chris
    Barnes, Nick
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2961 - 2964
  • [28] Multifocal Microlens for Bionic Compound eye
    Cao, Axiu
    Wang, Jiazhou
    Pang, Hui
    Zhang, Man
    Shi, Lifang
    Deng, Qiling
    Hu, Song
    AOPC 2017: OPTOELECTRONICS AND MICRO/NANO-OPTICS, 2017, 10460
  • [29] Surgical innovations: the bionic eye implant
    Yee, Shokjean
    AORN JOURNAL, 2017, 105 (03) : P13 - P14
  • [30] Development of imaging system with bionic moth-eye anti-reflection structure
    Dong T.
    Zhang G.
    Guo J.
    Wu J.
    Zhang W.
    Fu Y.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2019, 48 (01):