Development of a Magnetic Attachment Method for Bionic Eye Applications

被引:7
|
作者
Fox, Kate [1 ,3 ]
Meffin, Hamish [2 ,4 ]
Burns, Owen [5 ]
Abbott, Carla J. [6 ]
Allen, Penelope J. [6 ]
Opie, Nicholas L. [6 ]
McGowan, Ceara [5 ]
Yeoh, Jonathan [6 ]
Ahnood, Arman [1 ]
Luu, Chi D. [6 ]
Cicione, Rosemary [1 ]
Saunders, Alexia L. [5 ]
McPhedran, Michelle [5 ]
Cardamone, Lisa [5 ]
Villalobos, Joel [5 ]
Garrett, David J. [1 ,5 ]
Nayagam, David A. X. [5 ]
Apollo, Nicholas V. [1 ,5 ]
Ganesan, Kumaravelu [1 ]
Shivdasani, Mohit N. [5 ]
Stacey, Alastair [1 ]
Escudie, Mathilde [1 ]
Lichter, Samantha [1 ]
Shepherd, Robert K. [5 ]
Prawer, Steven [1 ]
机构
[1] Univ Melbourne, Sch Phys, Melbourne, Vic, Australia
[2] Univ Melbourne, Dept Elect & Elect Engn, Melbourne, Vic, Australia
[3] RMIT Univ, Sch Aerosp Mech & Mfg Engn, Melbourne, Vic, Australia
[4] Australian Coll Optometry, Natl Vis Res Inst, Melbourne, Vic, Australia
[5] Bion Inst, Melbourne, Vic, Australia
[6] Royal Victorian Eye & Ear Hosp, Ctr Eye Res Australia, Melbourne, Vic 3002, Australia
基金
澳大利亚国家健康与医学研究理事会; 澳大利亚研究理事会;
关键词
Magnet; Bionic eye; Attachment; Retina; SUPRACHOROIDAL RETINAL PROSTHESIS; NDFEB PERMANENT-MAGNETS; CORROSION BEHAVIOR; BIOMEDICAL IMPLANTS; ACID-SOLUTIONS; IN-VIVO; STIMULATION; DIAMOND; ADHESIVE; COATINGS;
D O I
10.1111/aor.12582
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Successful visual prostheses require stable, long-term attachment. Epiretinal prostheses, in particular, require attachment methods to fix the prosthesis onto the retina. The most common method is fixation with a retinal tack; however, tacks cause retinal trauma, and surgical proficiency is important to ensure optimal placement of the prosthesis near the macula. Accordingly, alternate attachment methods are required. In this study, we detail a novel method of magnetic attachment for an epiretinal prosthesis using two prostheses components positioned on opposing sides of the retina. The magnetic attachment technique was piloted in a feline animal model (chronic, nonrecovery implantation). We also detail a new method to reliably control the magnet coupling force using heat. It was found that the force exerted upon the tissue that separates the two components could be minimized as the measured force is proportionately smaller at the working distance. We thus detail, for the first time, a surgical method using customized magnets to position and affix an epiretinal prosthesis on the retina. The position of the epiretinal prosthesis is reliable, and its location on the retina is accurately controlled by the placement of a secondary magnet in the suprachoroidal location. The electrode position above the retina is less than 50 microns at the center of the device, although there were pressure points seen at the two edges due to curvature misalignment. The degree of retinal compression found in this study was unacceptably high; nevertheless, the normal structure of the retina remained intact under the electrodes.
引用
收藏
页码:E12 / E24
页数:13
相关论文
共 50 条
  • [1] The Bionic Eye
    Lorach, Henri
    SCIENTIST, 2014, 28 (10): : 32 - 33
  • [2] A bionic study of the magnetic bacteria with applications to the mecano-magnetic micromanipulators
    Elena, Yuan FengYuan
    Mircea, Ignat
    Ioan, Ardelean
    13TH GLOBAL CONGRESS ON MANUFACTURING AND MANAGEMENT, 2017, 174 : 1128 - 1139
  • [3] The Bionic Eye A Quarter Century of Retinal Prosthesis Research and Development
    Humayun, Mark S.
    de Juan, Eugene, Jr.
    Dagnelie, Gislin
    OPHTHALMOLOGY, 2016, 123 (10) : S89 - S97
  • [4] Towards the bionic eye
    Kaufman, David V.
    ANZ JOURNAL OF SURGERY, 2016, 86 (09) : 635 - 635
  • [5] Bionic Eye Technology
    Dharsini, B. Harini Priya
    Devi, M. Renuka
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2022, 12 : 134 - 137
  • [6] The bionic eye: a review
    Ong, Jong Min
    da Cruz, Lyndon
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (01): : 6 - 17
  • [7] Bionic mosaic method of panoramic image based on compound eye of fly
    Haipeng Chen
    Xuanjing Shen
    Xiaofei Li
    Yushan Jin
    Journal of Bionic Engineering, 2011, 8 : 440 - 448
  • [8] Bionic tracking method by hand & eye-vergence visual servoing
    Song, Wei
    Minami, Mamoru
    Shen, Lin-Yong
    Zhang, Ya-Nan
    ADVANCES IN MANUFACTURING, 2016, 4 (02) : 157 - 166
  • [9] Model Independent PD-SMC Method for Bionic Eye Systems
    Liu, Bin
    Zhang, Menghua
    Ma, Xin
    Song, Rui
    Rong, Xuewen
    Tian, Xincheng
    Tian, Guohui
    Li, Yibin
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 676 - 681
  • [10] Bionic tracking method by hand & eye-vergence visual servoing
    Wei Song
    Mamoru Minami
    Lin-Yong Shen
    Ya-Nan Zhang
    Advances in Manufacturing, 2016, 4 : 157 - 166