Coronary sinus flow measurement by means of velocity-encoded cine MR imaging:: Validation by using flow probes in dogs

被引:38
|
作者
Lund, GK
Wendland, MF
Shimakawa, A
Arheden, H
Ståhlberg, F
Higgins, CB
Saeed, M
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Univ Lund Hosp, Dept Clin Physiol, S-22185 Lund, Sweden
[3] Univ Lund Hosp, Dept Radiat Phys, S-22185 Lund, Sweden
[4] GE Med Syst, Milwaukee, WI USA
关键词
coronary vessels; flow dynamics; MR; stenosis or obstruction; magnetic resonance (MR); cine studies; experimental studies; vascular studies; myocardium. blood supply;
D O I
10.1148/radiology.217.2.r00nv10487
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To validate coronary sinus flow measurements for quantification of global left ventricular (LV) perfusion by means of velocity-encoded cine (VEC) magnetic resonance (MR) imaging and flow probes. MATERIALS AND METHODS: Measurements of coronary sinus flow were performed in seven dogs by using VEC MR imaging at baseline, single coronary arterial stenosis, dipyridamole stress, and reactive hyperemia. These measurements were compared with flow probe measurements of coronary blood flow (CBF) in the left anterior descending coronary (LAD) and circumflex (CFX) arteries (CBFLAD+CFX) and coronary sinus. LV blood perfusion was calculated in milliliters per minute per gram from coronary sinus flow, and LV mass was obtained by using VEC and cine MR imaging. LV mass was validated at autopsy. RESULTS: CBFLAD+CFX and coronary sinus flow at VEC MR imaging showed close correlation (r = 0.98, P < .001). The difference between CBFLAD+CFX and MR coronary sinus flow was 3.1 mL/min +/- 8.5 (SD). LV mass at cine MR imaging was not significantly different from that at autopsy (73.2 g +/- 12.8 vs 69.4 g +/- 12.8). At baseline, myocardial perfusion was 0.40 mL/min/g +/- 0.09 at VEC MR imaging, and CBFLAD+CFX was 0.44 ml/min/g +/- 0.08 (not significant). Reactive hyperemia resulted in 2.7- and 2.3-fold increases in coronary sinus flow at VEC MR imaging and flow probe CBFLAD+CFX respectively. CONCLUSION: VEC MR imaging has the potential to measure coronary sinus flow during different physiologic conditions and can serve as a noninvasive modality to quantify global LV perfusion in patients.
引用
收藏
页码:487 / 493
页数:7
相关论文
共 50 条
  • [1] Coronary sinus flow measurement by velocity-encoded cine MR imaging: Validation by Doppler flow probes
    Lund, GK
    Wendland, MF
    Shimakawa, A
    Higgins, B
    Saeed, M
    CIRCULATION, 1999, 100 (18) : 457 - 457
  • [2] Quantification of coronary artery volume flow rate using fast velocity-encoded cine MR imaging
    Sakuma, H
    Saeed, M
    Takeda, K
    Wendland, MF
    Schwitter, J
    Szolar, DH
    Derugin, N
    Shimakawa, A
    Foo, TKF
    Higgins, CB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) : 1363 - 1367
  • [3] Coronary flow reserve: Noninvasive measurement in humans with breath-hold velocity-encoded cine MR imaging
    Sakuma, H
    Blake, LM
    Amidon, TM
    OSullivan, M
    Szolar, DH
    Furber, AP
    Bernstein, MA
    Foo, TKF
    Higgins, CB
    RADIOLOGY, 1996, 198 (03) : 745 - 750
  • [4] Assessment of flow quantification in coronary bypass grafts and coronary arteries with velocity-encoded cine MR imaging
    Kreitner, KF
    Voigtländer, T
    Wittlinger, T
    Dahm, M
    Kalden, P
    Meyer, J
    Thelen, M
    RADIOLOGE, 2000, 40 (02): : 143 - 149
  • [5] Assessment of coronary flow reserve using fast velocity-encoded cine MR imaging: Validation study using positron emission tomography
    Sakuma, H
    Koskenvuo, JW
    Niemi, P
    Kawada, N
    Toikka, JO
    Knuuti, J
    Laine, H
    Saraste, M
    Kormano, M
    Hartiala, JJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (04) : 1029 - 1033
  • [6] Measurement of phasic coronary flow with velocity encoded cine MR imaging and respiratory gating
    Post, JC
    Hofman, MB
    Galjee, MA
    vanRossum, AC
    CIRCULATION, 1996, 94 (08) : 711 - 711
  • [7] PULMONARY-HYPERTENSION - PULMONARY FLOW QUANTIFICATION AND FLOW PROFILE ANALYSIS WITH VELOCITY-ENCODED CINE MR IMAGING
    KONDO, C
    CAPUTO, GR
    MASUI, T
    FOSTER, E
    OSULLIVAN, M
    STULBARG, MS
    GOLDEN, J
    CATTERJEE, K
    HIGGINS, CB
    RADIOLOGY, 1992, 183 (03) : 751 - 758
  • [8] Quantification of flow dynamics in congenital heart disease: Applications of velocity-encoded cine MR imaging
    Varaprasathan, GA
    Araoz, PA
    Higgins, CB
    Reddy, GP
    RADIOGRAPHICS, 2002, 22 (04) : 895 - 905
  • [9] FLOW PATTERN-ANALYSIS IN THE ABDOMINAL-AORTA WITH VELOCITY-ENCODED CINE MR-IMAGING
    MOSTBECK, GH
    DULCE, MC
    CAPUTO, GR
    PROCTOR, E
    HIGGINS, CB
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04): : 617 - 623
  • [10] Myocardial blood flow in patients with dilated cardiomyopathy: Quantitative assessment with velocity-encoded cine magnetic resonance imaging of the coronary sinus
    Watzinger, N
    Lund, GK
    Saeed, M
    Reddy, GP
    Araoz, PA
    Yang, M
    Schwartz, AB
    Bedigian, M
    Higgins, CB
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) : 347 - 353