Assessment of Device-Related Thrombus and Associated Clinical Outcomes With the WATCHMAN Left Atrial Appendage Closure Device for Embolic Protection in Patients With Atrial Fibrillation (from the PROTECT-AF Trial)

被引:96
|
作者
Main, Michael L. [1 ]
Fan, Dali [2 ]
Reddy, Vivek Y. [3 ]
Holmes, David R. [4 ]
Gordon, Nicole T. [5 ]
Coggins, Tina R. [1 ]
House, John A. [1 ]
Liao, Lawrence [6 ]
Rabineau, Dawn [6 ]
Latus, George G. [5 ]
Huber, Kenneth C. [1 ]
Sievert, Horst [7 ]
Wright, Richard F. [8 ]
Doshi, Shephal K. [8 ]
Douglas, Pamela S. [6 ]
机构
[1] St Lukes Mid Amer Heart Inst, Kansas City, MO USA
[2] Univ Calif Davis, Med Ctr, Sacramento, CA 95817 USA
[3] Mt Sinai Sch Med, New York, NY USA
[4] Mayo Clin, Rochester, MN USA
[5] Boston Sci Corp, St Paul, MN USA
[6] Duke Univ, Med Ctr, Durham, NC USA
[7] Cardiovasc Ctr Frankfurt, Frankfurt, Germany
[8] St Johns Hlth Ctr, Pacific Heart Inst & Providence, Santa Monica, CA USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2016年 / 117卷 / 07期
关键词
SPONTANEOUS ECHO CONTRAST; AMPLATZER CARDIAC PLUG; THROMBOEMBOLIC RISK; AMERICAN-SOCIETY; ECHOCARDIOGRAPHY; STROKE; STANDARDS; VELOCITY; WARFARIN; SYSTEM;
D O I
10.1016/j.amjcard.2016.01.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Left atrial appendage closure with the WATCHMAN device is an alternative to anticoagulation for stroke prevention in selected patients with atrial fibrillation (AF). LA device-related thrombus (DRT) is poorly defined and understood. We aimed to (1) develop consensus echocardiographic diagnostic criteria for DRT; (2) estimate the incidence of DRT; and (3) determine clinical event rates in patients with DRT. In phase 1 (training), a training manual was developed and reviewed by 3 echocardiographers with left atrial appendage closure device experience. All available transesophageal (TEE) studies in the WATCHMAN left atrial appendage system for embolic protection in patients with atrial fibrillation (PROTECT-AF) trial patients with suspected DRT were reviewed in 2 subsequent phases. In phase 2 (primary blind read), each reviewer independently scored each study for DRT, and final echo criteria were developed. Unanimously scored studies were considered adjudicated, whereas all others were reevaluated by all reviewers in phase 3 (group adjudication read). DRT was suspected in 35 of 485 patients by the site investigator, the echocardiography core laboratory, or both; 93 of the individual TEE studies were available for review. In phase 2, 3 readers agreed on 67 (72%) of time points. Based on phases 1 and 2, 5 DRT criteria were developed. In phase 3, studies without agreement in phase 2 were adjudicated using these Criteria. Overall, at least 1 TEE was DRT positive in 27 (5.7%) PROTECT-AF patients. Stroke, peripheral embolism, or cardiac/unexplained death occurred in subjects with DRT at a rate of 3.4 per 100 patient-years follow-up. In conclusion, DRT were identified on at least 1 TEE in 27 PROTECT-AF patients, indicating a DRT incidence of 5.7%. Primary efficacy events in patients with DRT occurred at a rate of 3.4 per 100 patient-years follow-up, intermediate in frequency between event rates previously reported for the overall device and warfarin arms in PROTECT-AF. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1127 / 1134
页数:8
相关论文
共 50 条
  • [1] The PROTECT AF (WATCHMAN Left Atrial Appendage System for embolic PROTECTion in patients with atrial fibrillation) trial
    Fountain, RB
    Holmes, DR
    Chandrasekaran, K
    Packer, D
    Asirvatham, S
    Van Tassel, R
    Turi, Z
    AMERICAN HEART JOURNAL, 2006, 151 (05) : 956 - 961
  • [2] DEVICE-RELATED THROMBUS AFTER LEFT ATRIAL APPENDAGE CLOSURE WITH WATCHMAN: INCIDENCE, PREDICTORS AND OUTCOMES
    Reddy, Vivek Y.
    Kar, Saibal
    Holmes, David R.
    Doshi, Shephal K.
    Swarup, Vijendra
    Gibson, Douglas N.
    Dukkipati, Srinivas R.
    Gordon, Nicole T.
    Main, Michael L.
    HEART RHYTHM, 2018, 15 (06) : 944 - 945
  • [3] Incidence and predictors of device-related thrombus after left atrial appendage closure with Watchman device
    Maksym, Jakub
    Scislo, Piotr
    Kaplon-Cieslicka, Agnieszka
    Huczek, Zenon
    Marchel, Michal
    Kochman, Janusz
    Zbronski, Karol
    Opolski, Grzegorz
    Grabowski, Marcin
    Mazurek, Tomasz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2024, 20 (02): : 164 - 171
  • [4] The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
    Moebius-Winkler, Sven
    Sandri, Marcus
    Mangner, Norman
    Lurz, Phillip
    Daehnert, Ingo
    Schuler, Gerhard
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2012, (60):
  • [5] Safety of Percutaneous Left Atrial Appendage Closure Results From the Watchman Left Atrial Appendage System for Embolic Protection in Patients With AF (PROTECT AF) Clinical Trial and the Continued Access Registry
    Reddy, Vivek Y.
    Holmes, David
    Doshi, Shephal K.
    Neuzil, Petr
    Kar, Saibal
    CIRCULATION, 2011, 123 (04) : 417 - 424
  • [6] DEVICE-RELATED THROMBUS FOLLOWING LEFT ATRIAL APPENDAGE CLOSURE: A CLINICAL CONUNDRUM
    Jazayeri, Mohammad-Ali
    Vuddanda, Venkat Lakshmi Kishan
    Reddy, Madhu
    Lakkireddy, Dhanunjaya
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 2296 - 2296
  • [7] The Clinical Impact of Incomplete Left Atrial Appendage Closure With the Watchman Device in Patients With Atrial Fibrillation
    Viles-Gonzalez, Juan F.
    Kar, Saibal
    Douglas, Pamela
    Dukkipati, Srinivas
    Feldman, Ted
    Horton, Rodney
    Holmes, David
    Reddy, Vivek Y.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (10) : 923 - 929
  • [9] Device-Related Thrombus After Transcatheter Left Atrial Appendage Closure
    Price, Matthew J.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (11) : 1015 - 1017
  • [10] Treatment and Outcomes of Device-Related Thrombus After Transcatheter Left Atrial Appendage Closure
    Yoo, David H.
    Gibson, Douglas N.
    Funk, Jessica
    Pangborn, Kristi
    Janczyk, Gwen
    Price, Matthew J.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (11)