Are We Being Fooled by Fluoroscopy? Distortion May Affect Limb-Length Measurements in Direct Anterior Total Hip Arthroplasty

被引:11
|
作者
Carlson, Victor R. [1 ]
Elliott, Iain S. [2 ]
DeKeyser, Graham J. [1 ]
Pelt, Christopher E. [1 ]
Anderson, Lucas A. [1 ]
Gililland, Jeremy M. [1 ]
机构
[1] Univ Utah, Dept Orthopaed, 590 Wakara Way, Salt Lake City, UT 84108 USA
[2] Univ Washington, Harborview Med Ctr, Dept Orthopaed, Seattle, WA 98104 USA
来源
JOURNAL OF ARTHROPLASTY | 2021年 / 36卷 / 05期
关键词
direct anterior total hip arthroplasty; image-intensified fluoroscopy; distortion; limb-length measurements; component positioning; AAPM/RSNA PHYSICS TUTORIAL; GEOMETRIC IMAGE DISTORTION; LEG LENGTH; GLOBAL METHOD; DISCREPANCY; DISLOCATION; RESIDENTS; AGREEMENT; POSITION;
D O I
10.1016/j.arth.2020.11.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distortion is an intrinsic phenomenon associated with image-intensified fluoroscopy that is both poorly understood and infrequently appreciated by orthopedic surgeons. Little information exists regarding its potential influence on intraoperative parameters during orthopedic surgery, let alone during direct anterior (DA) total hip arthroplasty (THA). The purpose of this study was to quantify the amount of potential error caused by fluoroscopic distortion during DA THA. Methods: Intra-operative fluoroscopic pelvic images from 74 DA THAs were reviewed by two independent readers. All images were obtained using the same fluoroscopic C-arm unit with a radiopaque grid attached to the image intensifier. The vertical distortion from a straight central horizontal line at the peripheries of images were measured and summed to yield the combined vertical distortion similar to how a surgeon calculates a side to side comparison of limb lengths. Simple linear regression was used to evaluate associations between total distortion and patient demographics, operating theaters, and various operative parameters. Results: The average combined distortion was 10.0mm (range 2.0-20.0mm). There was a significant difference in the average distortion observed in different theaters (P <.001). There was no association between distortion and patient demographics or fluoroscopic time (all, P >.05). Conclusion: Fluoroscopic distortion is unpredictable and can cause a substantial amount of error when comparing limb lengths during DA THA. This is a critical finding as this amount of inaccuracy could lead to unintended implant positioning and limb-length discrepancies if unaccounted for. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:1799 / 1803
页数:5
相关论文
共 50 条
  • [41] Optimizing implant positioning in total hip arthroplasty via the direct anterior approach: The role and technique of conventional traction table and fluoroscopy
    Ishii, Seiya
    Baba, Tomonori
    Hayashi, Koju
    Homma, Yasuhiro
    Muto, Osamu
    Ishijima, Muneaki
    ARTHROPLASTY, 2025, 7 (01)
  • [42] Letter to the Editor on "Patient Characteristics and Surgical Start Time Affect Length of Stay Following Anterior Total Hip Arthroplasty"
    George, Jaiben
    Gautam, Deepak
    Malhotra, Rajesh
    JOURNAL OF ARTHROPLASTY, 2020, 35 (11): : 3425 - 3426
  • [43] Total hip arthroplasty via the direct anterior approach using a conventional traction table and fluoroscopy: a safe and cost-effective technique
    Ishii, Seiya
    Baba, Tomonori
    Hayashi, Koju
    Homma, Yasuhiro
    Mutou, Osamu
    Ishijima, Muneaki
    SICOT-J, 2024, 10
  • [44] Does the thigh circumference affect the positioning of the acetabular component when using the direct anterior approach in total hip arthroplasty?
    Jacobs, C. A.
    Kusema, E. T.
    Keeney, B. J.
    Moschetti, W. E.
    BONE & JOINT JOURNAL, 2019, 101B (05): : 529 - 535
  • [45] Reliability of a simple fluoroscopic image to assess leg length discrepancy during direct anterior approach total hip arthroplasty
    Caus, Sandi
    Reist, Hailee
    Bernard, Christopher
    Blankstein, Michael
    Nelms, Nathaniel J.
    WORLD JOURNAL OF ORTHOPEDICS, 2021, 12 (11): : 850 - 858
  • [46] Impact of Dexamethasone on Length of Stay and Early Pain Control in Direct Anterior Approach Total Hip Arthroplasty With Neuraxial Anesthesia
    Kelly, McKayla E.
    Turcotte, Justin J.
    Aja, Jacob M.
    MacDonald, James H.
    King, Paul J.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (03): : 1009 - 1012
  • [47] Cementless Tapered-Wedge Stem Length Affects the Risk of Periprosthetic Femoral Fractures in Direct Anterior Total Hip Arthroplasty
    Tamaki, Tatsuya
    Jonishi, Kurato
    Miura, Yoko
    Oinuma, Kazuhiro
    Shiratsuchi, Hideaki
    JOURNAL OF ARTHROPLASTY, 2018, 33 (03): : 805 - 809
  • [48] General vs Neuraxial Anesthesia in Direct Anterior Approach Total Hip Arthroplasty: Effect on Length of Stay and Early Pain Control
    Kelly, McKayla E.
    Turcotte, Justin J.
    Aja, Jacob M.
    MacDonald, James H.
    King, Paul J.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (03): : 1013 - 1017
  • [49] Fluoroscopy-guided direct anterior approach total hip arthroplasty provides more accurate component positions in the supine position than in the lateral position
    Penglei Chen
    Wangxin Liu
    Cong Wu
    Pengfei Ruan
    Jicheng Zeng
    Weifeng Ji
    BMC Musculoskeletal Disorders, 24
  • [50] Fluoroscopy-guided direct anterior approach total hip arthroplasty provides more accurate component positions in the supine position than in the lateral position
    Chen, Penglei
    Liu, Wangxin
    Wu, Cong
    Ruan, Pengfei
    Zeng, Jicheng
    Ji, Weifeng
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)