Are We Being Fooled by Fluoroscopy? Distortion May Affect Limb-Length Measurements in Direct Anterior Total Hip Arthroplasty

被引:11
|
作者
Carlson, Victor R. [1 ]
Elliott, Iain S. [2 ]
DeKeyser, Graham J. [1 ]
Pelt, Christopher E. [1 ]
Anderson, Lucas A. [1 ]
Gililland, Jeremy M. [1 ]
机构
[1] Univ Utah, Dept Orthopaed, 590 Wakara Way, Salt Lake City, UT 84108 USA
[2] Univ Washington, Harborview Med Ctr, Dept Orthopaed, Seattle, WA 98104 USA
来源
JOURNAL OF ARTHROPLASTY | 2021年 / 36卷 / 05期
关键词
direct anterior total hip arthroplasty; image-intensified fluoroscopy; distortion; limb-length measurements; component positioning; AAPM/RSNA PHYSICS TUTORIAL; GEOMETRIC IMAGE DISTORTION; LEG LENGTH; GLOBAL METHOD; DISCREPANCY; DISLOCATION; RESIDENTS; AGREEMENT; POSITION;
D O I
10.1016/j.arth.2020.11.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distortion is an intrinsic phenomenon associated with image-intensified fluoroscopy that is both poorly understood and infrequently appreciated by orthopedic surgeons. Little information exists regarding its potential influence on intraoperative parameters during orthopedic surgery, let alone during direct anterior (DA) total hip arthroplasty (THA). The purpose of this study was to quantify the amount of potential error caused by fluoroscopic distortion during DA THA. Methods: Intra-operative fluoroscopic pelvic images from 74 DA THAs were reviewed by two independent readers. All images were obtained using the same fluoroscopic C-arm unit with a radiopaque grid attached to the image intensifier. The vertical distortion from a straight central horizontal line at the peripheries of images were measured and summed to yield the combined vertical distortion similar to how a surgeon calculates a side to side comparison of limb lengths. Simple linear regression was used to evaluate associations between total distortion and patient demographics, operating theaters, and various operative parameters. Results: The average combined distortion was 10.0mm (range 2.0-20.0mm). There was a significant difference in the average distortion observed in different theaters (P <.001). There was no association between distortion and patient demographics or fluoroscopic time (all, P >.05). Conclusion: Fluoroscopic distortion is unpredictable and can cause a substantial amount of error when comparing limb lengths during DA THA. This is a critical finding as this amount of inaccuracy could lead to unintended implant positioning and limb-length discrepancies if unaccounted for. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:1799 / 1803
页数:5
相关论文
共 50 条
  • [31] Direct anterior approach in total hip arthroplasty: more indications and advantages than we found
    Xu, Zhonghua
    Zhang, Jun
    Li, Jie
    Zhang, Yuan
    ARTHROPLASTY, 2022, 4 (01)
  • [32] Direct anterior approach in total hip arthroplasty: more indications and advantages than we found
    Zhonghua Xu
    Jun Zhang
    Jie Li
    Yuan Zhang
    Arthroplasty, 4
  • [33] Patient Characteristics and Surgical Start Time Affect Length of Stay Following Anterior Total Hip Arthroplasty
    Martinkovich, Stephen C.
    Trott, Gage L.
    Garay, Mariano
    Sewecke, Jeffrey J.
    Sauber, Timothy J.
    Sotereanos, Nicholas G.
    JOURNAL OF ARTHROPLASTY, 2020, 35 (08): : 2114 - 2118
  • [34] A Comparison of Radiographic Outcomes After Total Hip Arthroplasty Between the Posterior Approach and Direct Anterior Approach With Intraoperative Fluoroscopy
    Lin, Timothy J.
    Bendich, Ilya
    Ha, Alex S.
    Keeney, Benjamin J.
    Moschetti, Wayne E.
    Tomek, Ivan M.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (02): : 616 - 623
  • [35] Reliability and accuracy of intraoperative fluoroscopy assessment of acetabular cup anteversion in supine direct anterior approach total hip arthroplasty
    Li, Weihua
    Huang, Yan
    Zou, Zehui
    Liu, Xuqiang
    Li, Xiaofeng
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [36] Accuracy of Leg Length and Hip Offset Measurements Using a Fluoroscopic Grid During Anterior Approach Total Hip Arthroplasty
    Doehrmann, Ross
    Comer, Brendan J.
    Chatterji, Rishi
    Diedring, Benjamin
    Knapp, Paul
    Afsari, Alan
    ARTHROPLASTY TODAY, 2023, 22
  • [37] Efficacy of a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system in restoring limb length and offset
    Buchan, Graham B. J.
    Hecht, Christian J.
    Nugent, Mary
    Heckmann, Nathanael D.
    Kanaji, Arihiko
    Kamath, Atul F.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)
  • [38] Comparison of leg length discrepancy after total hip arthroplasty: Direct anterior and posterior lateral approach
    Lu, Yang
    Li, Xiang
    Hu, Yihe
    Zhao, Fengchao
    PLOS ONE, 2025, 20 (02):
  • [39] Two-stage total hip arthroplasty following skeletal traction after extensive soft tissue release for severe limb-length discrepancy
    Lee, Soong Joon
    Yoon, Kang Sup
    HIP INTERNATIONAL, 2021, 31 (02) : 223 - 230
  • [40] Direct Anterior Approach Total Hip Arthroplasty Using a Morphometrically Optimized Femoral Stem, a Conventional Operating Table, Without Fluoroscopy
    Tian, Shaoqi
    Goswami, Karan
    Manrique, Jorge
    Blevins, Kier
    Azboy, Ibrahim
    Hozack, William J.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (02): : 327 - 332