Are We Being Fooled by Fluoroscopy? Distortion May Affect Limb-Length Measurements in Direct Anterior Total Hip Arthroplasty

被引:11
|
作者
Carlson, Victor R. [1 ]
Elliott, Iain S. [2 ]
DeKeyser, Graham J. [1 ]
Pelt, Christopher E. [1 ]
Anderson, Lucas A. [1 ]
Gililland, Jeremy M. [1 ]
机构
[1] Univ Utah, Dept Orthopaed, 590 Wakara Way, Salt Lake City, UT 84108 USA
[2] Univ Washington, Harborview Med Ctr, Dept Orthopaed, Seattle, WA 98104 USA
来源
JOURNAL OF ARTHROPLASTY | 2021年 / 36卷 / 05期
关键词
direct anterior total hip arthroplasty; image-intensified fluoroscopy; distortion; limb-length measurements; component positioning; AAPM/RSNA PHYSICS TUTORIAL; GEOMETRIC IMAGE DISTORTION; LEG LENGTH; GLOBAL METHOD; DISCREPANCY; DISLOCATION; RESIDENTS; AGREEMENT; POSITION;
D O I
10.1016/j.arth.2020.11.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distortion is an intrinsic phenomenon associated with image-intensified fluoroscopy that is both poorly understood and infrequently appreciated by orthopedic surgeons. Little information exists regarding its potential influence on intraoperative parameters during orthopedic surgery, let alone during direct anterior (DA) total hip arthroplasty (THA). The purpose of this study was to quantify the amount of potential error caused by fluoroscopic distortion during DA THA. Methods: Intra-operative fluoroscopic pelvic images from 74 DA THAs were reviewed by two independent readers. All images were obtained using the same fluoroscopic C-arm unit with a radiopaque grid attached to the image intensifier. The vertical distortion from a straight central horizontal line at the peripheries of images were measured and summed to yield the combined vertical distortion similar to how a surgeon calculates a side to side comparison of limb lengths. Simple linear regression was used to evaluate associations between total distortion and patient demographics, operating theaters, and various operative parameters. Results: The average combined distortion was 10.0mm (range 2.0-20.0mm). There was a significant difference in the average distortion observed in different theaters (P <.001). There was no association between distortion and patient demographics or fluoroscopic time (all, P >.05). Conclusion: Fluoroscopic distortion is unpredictable and can cause a substantial amount of error when comparing limb lengths during DA THA. This is a critical finding as this amount of inaccuracy could lead to unintended implant positioning and limb-length discrepancies if unaccounted for. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:1799 / 1803
页数:5
相关论文
共 50 条
  • [1] Does Intraoperative Fluoroscopy Improve Limb-Length Discrepancy and Acetabular Component Positioning During Direct Anterior Total Hip Arthroplasty?
    Bingham, Joshua S.
    Spangehl, Mark J.
    Hines, Jeremy T.
    Taunton, Michael J.
    Schwartz, Adam J.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (09): : 2927 - 2931
  • [2] Limb-length Discrepancy After Total Hip Arthroplasty
    Harwin, Steven F.
    Pivec, Robert
    ORTHOPEDICS, 2014, 37 (02) : 78 - 79
  • [3] Does intraoperative fluoroscopy improve acetabular component positioning and limb-length discrepancy during direct anterior total hip arthroplasty? A meta-analysis
    Changjiao Sun
    Woo Guan Lee
    Qi Ma
    Xiaofei Zhang
    Zhe Zhao
    Xu Cai
    Journal of Orthopaedic Surgery and Research, 18
  • [4] Does intraoperative fluoroscopy improve acetabular component positioning and limb-length discrepancy during direct anterior total hip arthroplasty? A meta-analysis
    Sun, Changjiao
    Lee, Woo Guan
    Ma, Qi
    Zhang, Xiaofei
    Zhao, Zhe
    Cai, Xu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [5] Accurate limb-length equalization during total hip arthroplasty
    Bose, WJ
    ORTHOPEDICS, 2000, 23 (05) : 433 - 436
  • [6] Correction of limb-length inequality during total hip arthroplasty
    Ranawat, CS
    Rao, RR
    Rodriguez, JA
    Bhende, HS
    JOURNAL OF ARTHROPLASTY, 2001, 16 (06): : 715 - 720
  • [7] Radiographic review of limb-length discrepancy after total hip arthroplasty
    Winemaker, Mitchell
    Lopez, Carlos
    Staibano, Anthony
    Petruccelli, Danielle
    de Beer, Justin
    CURRENT ORTHOPAEDIC PRACTICE, 2010, 21 (05): : 504 - 507
  • [8] Surgical treatment of limb-length discrepancy following total hip arthroplasty
    Theruvil, B
    Kapoor, V
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (08): : 1829 - 1829
  • [9] Surgical treatment of limb-length discrepancy following total hip arthroplasty
    Parvizi, J
    Sharkey, PE
    Bissett, GA
    Rothman, RH
    Hozack, WJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12): : 2310 - 2317
  • [10] Preoperative Radiographic Assessment of Limb-length Discrepancy in Total Hip Arthroplasty
    Meermans, Geert
    Malik, Ahmad
    Witt, Johan
    Haddad, Fares
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (06) : 1677 - 1682