Importance of screw position in intertrochanteric femoral fractures treated by dynamic hip screw

被引:0
|
作者
Guven, M. [1 ]
Yavuz, U. [2 ]
Kadioglu, B. [3 ]
Akman, B. [4 ]
Kilincoglu, V. [5 ]
Unay, K. [3 ]
Altintas, F. [6 ]
机构
[1] Hosp Univ Abant Izzet Baysal, Dept Orthopaed & Traumatol, TR-14280 Bolu, Turkey
[2] Fatih Sultan Mehmet Training & Res Hosp, Orthopaed & Traumatol Clin, Istanbul, Turkey
[3] Goztepe Training & Res Hosp, Orthopaed & Traumatol Clin, Istanbul, Turkey
[4] Gulhane Mil Med Fac Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[5] Hosp Univ Dumlupinar, Dept Orthopaed & Traumatol, Kutahya, Turkey
[6] Yeditepe Univ, Dept Orthopaed & Traumatol, Sch Med, Istanbul, Turkey
关键词
Intertrochanteric fracture; Dynamic hip screw; Screw position; Tip-apex distance; TIP-APEX DISTANCE; TROCHANTERIC FRACTURES; INTERNAL-FIXATION; PLATE FIXATION; FAILURE; OSTEOPOROSIS; INDEX; FEMUR; END;
D O I
10.1016/j.otsr.2009.10.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Tip-apex distance greater than 25 mm is accepted as a strong predictor of screw cut-out in patients with intertrochanteric femoral fracture treated by dynamic hip screw. The aim of this retrospective study was to evaluate the position of the screw in the femoral head and its effect on cut-out failure especially in patients with inconvenient tip-apex distance. Patients and methods: Sixty-five patients (42 males, 23 females; mean age of 57.6 years) operated by dynamic hip screw for intertrochanteric femoral fractures were divided in two groups taking into consideration the tip-apex distance less (Group A; 14 patients) or more (Group B; 51 patients) than 25 mm. Patient's age and gender, follow-up period, fracture type, degree of osteoporosis, reduction quality of the fracture, position of the screw in the femoral head, number of patients with cut-out failure and Harris hip score were compared. Results: The average follow-up time was 41.7 months. The mean tip-apex distance was 17.14 mm in Group A and 36.67 mm in Group B. One (7.1%) patient in Group A and three (5.8%) patients in Group B had screw cut-out. Except the screw position, no statistical differences were observed between two groups with regards to study data's. The screw was placed in femoral head more inferiorly (p = 0.045) on frontal and more posteriorly (p = 0.013) on sagital planes in Group B, while central placement of the screw was present in Group A. The common characteristic of three patients with screw cut-out in Group B was the position of the screw which was located in femoral head more superiorly and anteriorly after an acceptable fracture reduction. Conclusions: Peripheral placement of the screw in femoral head increases tip-apex distance. However, posterior and inferior locations may help to support posteromedial cortex and calcar femoral in unstable intertrochanteric fractures and reduce the risk of cut-out failure. Level of evidence: Level IV, retrospective series. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 50 条
  • [41] Treatment of cutout of a lag screw of a dynamic hip screw in an intertrochanteric fracture
    Wu, CC
    Shih, CH
    Chen, WJ
    Tai, CL
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1998, 117 (4-5) : 193 - 196
  • [42] Complications relating to accuracy of reduction of intertrochanteric fractures treated with a compressive hip screw
    Pinto, Francisco Guerra
    Dantas, Pedro
    Moreira, Rodrigo
    Mamede, Rosa
    Amaral, Luis Branco
    HIP INTERNATIONAL, 2010, 20 (02) : 221 - 228
  • [43] A Comparative Study of Functional Outcome Following Dynamic Hip Screw and Proximal Femoral Nailing for Intertrochanteric Fractures of the Femur
    Prakash, Anil Kumar
    Nagakumar, J. S.
    Shanthappa, Arun H.
    Venkataraman, Sagar
    Kamath, Amith
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (04)
  • [44] Computed Tomographic Image Analysis of Proximal Femoral Nail Antirotation and Dynamic Hip Screw in the Treatment of Intertrochanteric Fractures
    Teng, Yugang
    Zhang, Yuanzhen
    Wang, Zhenyu
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (08) : 1746 - 1752
  • [45] Proximal Femoral Nail vs. Dynamic Hip Screw in Treatment of Intertrochanteric Fractures: A Meta-Analysis
    Zhang, Kairui
    Zhang, Sheng
    Yang, Jun
    Dong, Weiqiang
    Wang, Shengnan
    Cheng, Yirong
    Al-Qwbani, Mohammed
    Wang, Qiang
    Yu, Bin
    MEDICAL SCIENCE MONITOR, 2014, 20 : 1628 - 1633
  • [46] Dynamic hip screw in the treatment of intertrochanteric fractures: a comparison of two fixation methods
    Yih-Shiunn Lee
    Hui-Ling Huang
    Ting-Ying Lo
    Chien-Rae Huang
    International Orthopaedics, 2007, 31 : 683 - 688
  • [47] A comparative study of proximal femoral locking compress plate, proximal femoral nail antirotation and dynamic hip screw in intertrochanteric fractures
    Zang, W.
    Liu, P. -F.
    Han, X. F.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2018, 22 : 119 - 123
  • [48] Fixation of Intertrochanteric Fractures: Dynamic Hip Screw versus Locking Compression Plate
    Mardani-Kivi, Mohsen
    Mirbolook, Ahmadreza
    Jahromi, Sina Khajeh
    Rad, Melina Rouhi
    TRAUMA MONTHLY, 2013, 18 (02) : 67 - 70
  • [49] Minimally Invasive Dynamic Hip Screw Fixation in Stable and Unstable Intertrochanteric Fractures
    Jana, Kanailal
    Jha, Dipak Kumar
    Chakraburtty, Tapas
    Mullick, Sunny Kumar
    Duttagupta, Swarnava
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 4 (07) : 71 - 74
  • [50] To Study the Effectiveness and Safety of Dynamic Hip Screw (DHS) Fixation for Intertrochanteric Fractures
    Awan, Malik Mohammad Yasin
    Amjad, Mohammad
    Shah, Abdullah
    Ahmed, Ijaz
    Shad, Muhammad Nauman
    Fatima, Ajaz
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2019, 13 (02): : 342 - 345