Importance of screw position in intertrochanteric femoral fractures treated by dynamic hip screw

被引:0
|
作者
Guven, M. [1 ]
Yavuz, U. [2 ]
Kadioglu, B. [3 ]
Akman, B. [4 ]
Kilincoglu, V. [5 ]
Unay, K. [3 ]
Altintas, F. [6 ]
机构
[1] Hosp Univ Abant Izzet Baysal, Dept Orthopaed & Traumatol, TR-14280 Bolu, Turkey
[2] Fatih Sultan Mehmet Training & Res Hosp, Orthopaed & Traumatol Clin, Istanbul, Turkey
[3] Goztepe Training & Res Hosp, Orthopaed & Traumatol Clin, Istanbul, Turkey
[4] Gulhane Mil Med Fac Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[5] Hosp Univ Dumlupinar, Dept Orthopaed & Traumatol, Kutahya, Turkey
[6] Yeditepe Univ, Dept Orthopaed & Traumatol, Sch Med, Istanbul, Turkey
关键词
Intertrochanteric fracture; Dynamic hip screw; Screw position; Tip-apex distance; TIP-APEX DISTANCE; TROCHANTERIC FRACTURES; INTERNAL-FIXATION; PLATE FIXATION; FAILURE; OSTEOPOROSIS; INDEX; FEMUR; END;
D O I
10.1016/j.otsr.2009.10.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Tip-apex distance greater than 25 mm is accepted as a strong predictor of screw cut-out in patients with intertrochanteric femoral fracture treated by dynamic hip screw. The aim of this retrospective study was to evaluate the position of the screw in the femoral head and its effect on cut-out failure especially in patients with inconvenient tip-apex distance. Patients and methods: Sixty-five patients (42 males, 23 females; mean age of 57.6 years) operated by dynamic hip screw for intertrochanteric femoral fractures were divided in two groups taking into consideration the tip-apex distance less (Group A; 14 patients) or more (Group B; 51 patients) than 25 mm. Patient's age and gender, follow-up period, fracture type, degree of osteoporosis, reduction quality of the fracture, position of the screw in the femoral head, number of patients with cut-out failure and Harris hip score were compared. Results: The average follow-up time was 41.7 months. The mean tip-apex distance was 17.14 mm in Group A and 36.67 mm in Group B. One (7.1%) patient in Group A and three (5.8%) patients in Group B had screw cut-out. Except the screw position, no statistical differences were observed between two groups with regards to study data's. The screw was placed in femoral head more inferiorly (p = 0.045) on frontal and more posteriorly (p = 0.013) on sagital planes in Group B, while central placement of the screw was present in Group A. The common characteristic of three patients with screw cut-out in Group B was the position of the screw which was located in femoral head more superiorly and anteriorly after an acceptable fracture reduction. Conclusions: Peripheral placement of the screw in femoral head increases tip-apex distance. However, posterior and inferior locations may help to support posteromedial cortex and calcar femoral in unstable intertrochanteric fractures and reduce the risk of cut-out failure. Level of evidence: Level IV, retrospective series. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 50 条
  • [31] Treatment of intertrochanteric fractures in elderly patients using dynamic hip screw
    Quang-Tri Le
    Minh-Hoang Nguyen
    MEDICAL SCIENCE, 2020, 24 (102) : 912 - 921
  • [32] Addition of an Anti-rotation Screw to the Dynamic Hip Screw for Femoral Neck Fractures
    Makki, Daoud
    Mohamed, Ahmed M.
    Gadiyar, Rajeev
    Patterson, Marc
    ORTHOPEDICS, 2013, 36 (07) : E865 - E868
  • [33] SERIAL CHANGE OF SLIDING IN INTERTROCHANTERIC FEMORAL FRACTURES TREATED WITH SLIDING SCREW SYSTEM
    NAKATA, K
    OHZONO, K
    HIROSHIMA, K
    TOGE, K
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1994, 113 (05) : 276 - 280
  • [34] Outcome of the Dynamic Helical Hip Screw System for Intertrochanteric Hip Fractures in the Elderly Patients
    O'Malley, Natasha T.
    Deeb, Andrew-Paul
    Bingham, Karilee W.
    Kates, Stephen L.
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2012, 3 (02) : 68 - 73
  • [35] Complications of Dynamic Hip Screw Treatment for Proximal Femoral Fractures
    Hrubina, M.
    Skotak, M.
    Behounek, J.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2010, 77 (05) : 395 - 401
  • [36] DYNAMIC HIP SCREW (DHS) IN FRACTURES OF THE FEMORAL-NECK
    RENZ, N
    BILAT, C
    BEREITER, H
    RUEDI, T
    LEUTENEGGER, A
    HELVETICA CHIRURGICA ACTA, 1993, 59 (04) : 543 - 546
  • [37] SLIDING SCREW PLATE FIXATION OF INTERTROCHANTERIC FEMORAL FRACTURES
    MULHOLLAND, RC
    GUNN, DR
    ORTH, MC
    JOURNAL OF TRAUMA, 1972, 12 (07): : 581 - +
  • [38] Sliding Hip Screw and Side Plate for Intertrochanteric Hip Fractures
    Shih, Yushane
    Bartschat, Nicholas I.
    Cheng, Edward Y.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2022, 12 (01):
  • [39] Use of the talon hip compression screw in intertrochanteric fractures of the hip
    Bramlet, DG
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (425) : 93 - 100
  • [40] Treatment of cutout of a lag screw of a dynamic hip screw in an intertrochanteric fracture
    C. C. Wu
    C. H. Shih
    W. J. Chen
    C. L. Tai
    Archives of Orthopaedic and Trauma Surgery, 1998, 117 : 193 - 196