Importance of screw position in intertrochanteric femoral fractures treated by dynamic hip screw

被引:0
|
作者
Guven, M. [1 ]
Yavuz, U. [2 ]
Kadioglu, B. [3 ]
Akman, B. [4 ]
Kilincoglu, V. [5 ]
Unay, K. [3 ]
Altintas, F. [6 ]
机构
[1] Hosp Univ Abant Izzet Baysal, Dept Orthopaed & Traumatol, TR-14280 Bolu, Turkey
[2] Fatih Sultan Mehmet Training & Res Hosp, Orthopaed & Traumatol Clin, Istanbul, Turkey
[3] Goztepe Training & Res Hosp, Orthopaed & Traumatol Clin, Istanbul, Turkey
[4] Gulhane Mil Med Fac Hosp, Dept Orthopaed & Traumatol, Istanbul, Turkey
[5] Hosp Univ Dumlupinar, Dept Orthopaed & Traumatol, Kutahya, Turkey
[6] Yeditepe Univ, Dept Orthopaed & Traumatol, Sch Med, Istanbul, Turkey
关键词
Intertrochanteric fracture; Dynamic hip screw; Screw position; Tip-apex distance; TIP-APEX DISTANCE; TROCHANTERIC FRACTURES; INTERNAL-FIXATION; PLATE FIXATION; FAILURE; OSTEOPOROSIS; INDEX; FEMUR; END;
D O I
10.1016/j.otsr.2009.10.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Tip-apex distance greater than 25 mm is accepted as a strong predictor of screw cut-out in patients with intertrochanteric femoral fracture treated by dynamic hip screw. The aim of this retrospective study was to evaluate the position of the screw in the femoral head and its effect on cut-out failure especially in patients with inconvenient tip-apex distance. Patients and methods: Sixty-five patients (42 males, 23 females; mean age of 57.6 years) operated by dynamic hip screw for intertrochanteric femoral fractures were divided in two groups taking into consideration the tip-apex distance less (Group A; 14 patients) or more (Group B; 51 patients) than 25 mm. Patient's age and gender, follow-up period, fracture type, degree of osteoporosis, reduction quality of the fracture, position of the screw in the femoral head, number of patients with cut-out failure and Harris hip score were compared. Results: The average follow-up time was 41.7 months. The mean tip-apex distance was 17.14 mm in Group A and 36.67 mm in Group B. One (7.1%) patient in Group A and three (5.8%) patients in Group B had screw cut-out. Except the screw position, no statistical differences were observed between two groups with regards to study data's. The screw was placed in femoral head more inferiorly (p = 0.045) on frontal and more posteriorly (p = 0.013) on sagital planes in Group B, while central placement of the screw was present in Group A. The common characteristic of three patients with screw cut-out in Group B was the position of the screw which was located in femoral head more superiorly and anteriorly after an acceptable fracture reduction. Conclusions: Peripheral placement of the screw in femoral head increases tip-apex distance. However, posterior and inferior locations may help to support posteromedial cortex and calcar femoral in unstable intertrochanteric fractures and reduce the risk of cut-out failure. Level of evidence: Level IV, retrospective series. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 50 条
  • [1] Reverse oblique intertrochanteric femoral fractures treated with the intramedullary hip screw (IMHS)
    Chou, Daud Tai Shan
    Taylor, Andrew M.
    Boulton, Chris
    Moran, Chris G.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (06): : 817 - 821
  • [2] The prognostic value of the hip screw position in intertrochanteric fractures
    Csonka Akos
    Ecseri Tamas
    Dozsai David
    Csonka Istvan
    Gargyan Istvan
    Varga Endre
    ORVOSI HETILAP, 2019, 160 (09) : 338 - 342
  • [3] Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly
    Harrington, P
    Nihal, A
    Singhania, AK
    Howell, FR
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (01): : 23 - 28
  • [4] Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures
    Upadhyay, Sachin
    Raza, H. K. T.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01) : 130 - 131
  • [5] Dynamic hip screw blade fixation for intertrochanteric hip fractures
    Leung, Frankie
    Gudushauri, Paata
    Yuen, Grace
    Lau, Tak-Wing
    Fang, Christian
    Chow, Shew-Ping
    JOURNAL OF ORTHOPAEDIC SURGERY, 2012, 20 (03): : 302 - 306
  • [6] Proximal femoral locking plate versus dynamic hip screw for unstable intertrochanteric femoral fractures
    Dhamangaonkar, Anoop C.
    Joshi, Deepak
    Goregaonkar, Arvind B.
    Tawari, Akhil A.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (03) : 317 - 322
  • [7] Dynamic hip screw blade fixation for intertrochanteric hip fractures
    Dhamangaonkar, Anoop C.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (01) : 132 - 133
  • [8] THE MANAGEMENT OF INTERTROCHANTERIC FRACTURES OF FEMUR BY DYNAMIC HIP SCREW
    Singh, Arvinder
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (74): : 15575 - 15579
  • [9] Comparison of Dynamic Hip Screw and Proximal Femoral Nailing Techniques in Stable Intertrochanteric Fractures
    Shiraz, Salman
    Shujauddin, Mohammad
    Hasan, Khalid
    Elramadi, Ahmed
    Ahmed, Ghalib
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [10] COMPARATIVE STUDY OF PROXIMAL FEMORAL NAILING AND DYNAMIC HIP SCREW FOR INTERTROCHANTERIC FRACTURES IN ADULTS
    Koduru, Satya Kumar
    Potluri, Siddharth
    Rao, C. Hanumantha
    Raghav, Srinivas T.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (35): : 2018 - 2021