Validation of a tonometric noninvasive arterial blood pressure monitor in the intensive care setting

被引:17
|
作者
Steiner, LA
Johnston, AJ
Salvador, R
Czosnyka, M
Menon, DK
机构
[1] Univ Cambridge, Addenbrookes Hosp, Dept Anaesthesia, Cambridge CB2 2QQ, England
[2] Univ Cambridge, Wolfson Brain Imaging Ctr, Cambridge, England
关键词
non-invasive blood pressure monitors; intensive care; adult;
D O I
10.1046/j.1365-2044.2003.03122.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Intra-arterial measurement is considered the gold standard for continuous, beat-to-beat arterial blood pressure monitoring. However, arterial cannulation can be difficult and may cause complications such as thrombosis and ischaemia. Recently, a tonometric system, the Colin CBM-7000 has been developed for noninvasive beat-to-beat measurement of arterial blood pressure from the radial artery. We assessed the level of agreement between the CBM-7000 and invasive radial artery measurements in 15 patients on a neuro-intensive care unit. Agreement of systolic, diastolic and mean arterial pressure values was limited, with approximate to 34% of mean arterial pressures differing by over 10 mmHg. In many cases, this was due to a downward drift of the noninvasive measurements over time. Furthermore, there was a tendency to underestimate low pressures and overestimate high pressures. In our opinion, the Colin CBM-7000 cannot be recommended for continuous blood pressure monitoring in the intensive care setting.
引用
收藏
页码:448 / 454
页数:7
相关论文
共 50 条
  • [21] EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITOR
    ABENSTEIN, JP
    STENSRUD, PE
    SPACKMAN, TN
    TARHAN, S
    ANESTHESIOLOGY, 1993, 79 (3A) : A504 - A504
  • [22] Automatic Noninvasive Measurement of Arterial Blood Pressure
    Nitzan, Meir
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2011, 14 (01) : 32 - 37
  • [23] Continuous Noninvasive Blood Pressure Monitoring of Beat-By-Beat Blood Pressure and Heart Rate Using Caretaker Compared With Invasive Arterial Catheter in the Intensive Care Unit
    Kwon, Younghoon
    Stafford, Patrick L.
    Enfield, Kyle
    Mazimba, Sula
    Baruch, Martin C.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (07) : 2012 - 2021
  • [24] Improving the Design of Arterial Blood Pressure Monitor
    Skorobogatova, Alyona
    Sutyagina, Anastasiya
    Anisimov, Aleksei
    PROCEEDINGS OF THE 20TH CONFERENCE OF OPEN INNOVATIONS ASSOCIATION (FRUCT 2017), 2017, : 406 - 412
  • [25] Noninvasive Blood Pressure Cuff-Induced Complications in Intensive Care Unit Patients
    Jodaki, Kurosh
    Marashi, Sayed Mahdi
    Hasani, Seyed Alireza
    IRANIAN JOURNAL OF NURSING AND MIDWIFERY RESEARCH, 2024, 29 (04) : 493 - 493
  • [26] NONINVASIVE BLOOD-PRESSURE MONITORING IN PRETERM INFANTS RECEIVING INTENSIVE-CARE
    EMERY, EF
    GREENOUGH, A
    EUROPEAN JOURNAL OF PEDIATRICS, 1992, 151 (02) : 136 - 139
  • [27] Estimation of Central Aortic Blood Pressure using a Noninvasive Automatic Blood Pressure Monitor
    Shih, Yuan-Ta
    Sun, Yi-Jung
    Chen, Chen-Huan
    Cheng, Hao-min
    Wei-Chih, Hu
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 497 - +
  • [28] Noninvasive Blood Pressure Measurement Using the NICCI Monitor in Adolescents During Intraoperative Anesthetic Care
    Owusu-Bediako, Kwaku
    Bekiroglu, Ismail
    Rice-Weimer, Julie
    Murillo-Deluquez, Marcelino
    Tobias, Joseph D.
    CARDIOLOGY RESEARCH, 2022, 13 (03) : 154 - 161
  • [29] VALIDATION OF A NONINVASIVE REGISTRY MONITOR OF OUT PATIENT BLOOD-PRESSURE - THE NOVACOR DIASYS-200
    MORAMACIA, J
    PUJADAS, JMO
    CUBELLS, TD
    PEREZ, GD
    MEDICINA CLINICA, 1993, 101 (12): : 450 - 454
  • [30] Reporting of blood pressure monitor validation studies
    Grover-Paez, Fernando
    Cardona-Munoz, Ernesto G.
    Cardona-Mueller, David
    Guzman-Saldivar, Victor H.
    Rodriguez-De la Cerda, Mariana
    Jimenez Cazarez, Mayra B.
    Totsuka-Sutto, Sylvia E.
    Alanis-Sanchez, Guillermo A.
    Ramos-Becerra, Carlos G.
    BLOOD PRESSURE MONITORING, 2018, 23 (04) : 216 - 217