A liquid core waveguide fluorescence detector for multicapillary electrophoresis applied to DNA sequencing in a 91-capillary array

被引:0
|
作者
Hanning, A
Westberg, J
Roeraade, J [1 ]
机构
[1] Royal Inst Technol, Dept Analyt Chem, S-10044 Stockholm, Sweden
[2] Royal Inst Technol, Dept Biotechnol, Stockholm, Sweden
关键词
capillary electrophoresis; fluorescence detection; DNA sequencing; capillary array; waveguide;
D O I
10.1002/1522-2683(20000901)21:15<3290::AID-ELPS3290>3.0.CO;2-J
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new laser-induced fluorescence (LIF) detector for multicapillary electrophoresis is presented. The detection principle is based on waveguiding of the emitted fluorescence from the point of illumination to the capillary ends by total internal reflection (TIR) and imaging of the capillary ends. The capillaries themselves thus act as liquid core waveguides (LCWs). At the illumination point, the capillaries are arranged in a planar array, which allows clean and efficient illumination with a line-focused laser beam. The capillary ends are rearranged into a small, densely packed two-dimensional array, which is imaged end-on with high light collection efficiency and excellent image quality. Wavelength dispersion is obtained with a single prism. Intercapillary optical crosstalk is less than 0.5%, and rejection of stray light is very efficient. The detector is applied to four-color DNA sequencing by gel electrophoresis in a 91-capillary array, with simple fluorescein and rhodamine dyes as fluorophores. Since the imaged two-dimensional array is so compact, the detector has a high potential for very large-scale multiplexing.
引用
收藏
页码:3290 / 3304
页数:15
相关论文
共 50 条
  • [31] CAPILLARY GEL-ELECTROPHORESIS FOR DNA SEQUENCING - LASER-INDUCED FLUORESCENCE DETECTION WITH THE SHEATH FLOW CUVETTE
    SWERDLOW, H
    WU, S
    HARKE, H
    DOVICHI, NJ
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01): : 61 - 67
  • [32] Accurate DNA fragment sizing by capillary electrophoresis with laser-induced fluorescence array for detection of sequence specificity of DNA damage
    Fundador, Erwin V.
    Choudhary, Dharamainder
    Schenkman, John B.
    Rusling, James F.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (06) : 2212 - 2221
  • [33] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND CAPILLARY GEL-ELECTROPHORESIS AS APPLIED TO ANTISENSE DNA
    COHEN, AS
    VILENCHIK, M
    DUDLEY, JL
    GEMBORYS, MW
    BOURQUE, AJ
    [J]. JOURNAL OF CHROMATOGRAPHY, 1993, 638 (02): : 293 - 301
  • [34] Fully Integrated Liquid-Core Waveguide Fluorescence Lifetime Detection Microsystem for DNA Biosensing
    Wei, Liping
    Leung, Hoi Man
    Tian, Yi
    Lo, Pik Kwan
    Ho, Derek
    [J]. IEEE ACCESS, 2019, 7 : 111944 - 111953
  • [35] Fluorescence detection system for capillary separations utilizing a liquid core waveguide with an optical fibre-coupled compact spectrometer
    Kostal, V
    Zeisbergerova, M
    Slais, K
    Kahle, V
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1081 (01) : 36 - 41
  • [36] Capillary isoelectric focusing of proteins with liquid core waveguide laser-induced fluorescence whole column imaging detection
    Liu, Z
    Pawliszyn, J
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (18) : 4887 - 4894
  • [37] Multiplex dye DNA sequencing in capillary gel electrophoresis by diode laser-based time-resolved fluorescence detection
    Lieberwirth, U
    Arden-Jacob, J
    Drexhage, KH
    Herten, DP
    Müller, R
    Neumann, M
    Schulz, A
    Siebert, S
    Sagner, G
    Klingel, S
    Sauer, M
    Wolfrum, J
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (22) : 4771 - 4779
  • [38] A laser diode double-pumped solid-state laser-induced fluorescence detector for capillary electrophoresis and liquid chromatography
    Yang, BC
    Tan, F
    Guan, YF
    [J]. LC GC NORTH AMERICA, 2005, 23 (10) : 1110 - +
  • [39] A laser diode double-pumped solid-state laser-induced fluorescence detector for capillary electrophoresis and liquid chromatography
    Yang, BC
    Tan, F
    Guan, YF
    [J]. LC GC NORTH AMERICA, 2006, : 77 - 81
  • [40] INTERNAL FLUORESCENCE LABELING WITH FLUORESCENT DEOXYNUCLEOTIDES IN 2-LABEL PEAK-HEIGHT ENCODED DNA-SEQUENCING BY CAPILLARY ELECTROPHORESIS
    STARKE, HR
    YAN, JY
    ZHANG, JZ
    MUHLEGGER, K
    EFFGEN, K
    DOVICHI, NJ
    [J]. NUCLEIC ACIDS RESEARCH, 1994, 22 (19) : 3997 - 4001