Comparison of DVH data from multiple radiotherapy treatment planning systems

被引:61
|
作者
Ebert, M. A. [1 ,2 ]
Haworth, A. [3 ,4 ]
Kearvell, R. [1 ]
Hooton, B. [1 ]
Hug, B. [5 ]
Spry, N. A. [1 ,6 ]
Bydder, S. A. [1 ,7 ]
Joseph, D. J. [1 ,7 ]
机构
[1] Sir Charles Gairdner Hosp, Dept Radiat Oncol, Perth, WA, Australia
[2] Univ Western Australia, Sch Phys, Perth, WA 6009, Australia
[3] Peter MacCallum Canc Ctr, Dept Phys Sci, Melbourne, Vic, Australia
[4] RMIT Univ, Sch Appl Sci, Melbourne, Vic, Australia
[5] Curtin Univ Technol, Bentley, WA 6102, Australia
[6] Univ Western Australia, Sch Med & Pharmacol, Perth, WA 6009, Australia
[7] Univ Western Australia, Sch Surg & Pathol, Perth, WA 6009, Australia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 11期
关键词
QUALITY-ASSURANCE; DOSIMETRY; IMPACT; SIZE;
D O I
10.1088/0031-9155/55/11/N04
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study examined the variation of dose-volume histogram (DVH) data sourced from multiple radiotherapy treatment planning systems (TPSs). Treatment plan exports were obtained from 33 Australian and New Zealand centres during a dosimetry study. Plan information, including DVH data, was exported from the TPS at each centre and reviewed in a digital review system (SWAN). The review system was then used to produce an independent calculation of DVH information for each delineated structure. The relationships between DVHs extracted from each TPS and independently calculated were examined, particularly in terms of the influence of CT scan slice and pixel widths, the resolution of dose calculation grids and the TPS manufacturer. Calculation of total volume and DVH data was consistent between SWAN and each TPS, with the small discrepancies found tending to increase with decreasing structure size. This was significantly influenced by the TPS model used to derive the data. For target structures covered with relatively uniform dose distributions, there was a significant difference between the minimum dose in each TPS-exported DVH and that calculated independently.
引用
收藏
页码:N337 / N346
页数:10
相关论文
共 50 条
  • [1] A simple DVH generation technique for various radiotherapy treatment planning systems for an independent information system
    Byung Jun Min
    Heerim Nam
    Il Sun Jeong
    Hyebin Lee
    Journal of the Korean Physical Society, 2015, 67 : 254 - 259
  • [2] A Simple DVH Generation Technique for Various Radiotherapy Treatment Planning Systems for an Independent Information System
    Min, Byung Jun
    Nam, Heerim
    Jeong, Il Sun
    Lee, Hyebin
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 254 - 259
  • [3] A Robustness Comparative Study of DVH Prediction Models for Knowledge Based Radiotherapy Treatment Planning
    Wu, A.
    Li, Y.
    Qi, M.
    Guo, F.
    Jia, Q.
    Zhou, L.
    Song, T.
    MEDICAL PHYSICS, 2019, 46 (06) : E236 - E237
  • [4] An Evaluation of the Reproducibility of Radiotherapy Contouring Utilizing Multiple Institutions and Treatment Planning Systems
    Pogson, E.
    McNamara, J.
    Jameson, M.
    McDowall, R.
    Lim, A.
    Dempsey, C.
    Metcalfe, P.
    Holloway, L.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [5] A DVH-guided IMRT optimization algorithm for automatic treatment planning and adaptive radiotherapy replanning
    Zarepisheh, Masoud
    Long, Troy
    Li, Nan
    Tian, Zhen
    Romeijn, H. Edwin
    Jia, Xun
    Jiang, Steve B.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [6] Accuracy of volume and DVH calculation with seven modern brachytherapy treatment planning systems
    Kirisits, C.
    Siebert, F-A.
    Baltas, D.
    De Brabandere, M.
    Hellebust, T. Paulsen
    Berger, D.
    Venselaar, J. L. M.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S94 - S95
  • [7] Accuracy of volume and DVH parameters determined with different brachytherapy treatment planning systems
    Kirisits, Christian
    Siebert, Frank-Andre
    Baltas, Dimos
    De Brabandere, Marisol
    Hellebust, Taran Paulsen
    Berger, Daniel
    Venselaar, Jack
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 (03) : 290 - 297
  • [8] Methods for transferring patient and plan data between radiotherapy treatment planning systems
    Bedford, JL
    Oldham, M
    Hoess, A
    Evans, PM
    Shentall, GS
    Webb, S
    BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (835): : 740 - 749
  • [9] A Data-driven Approach to Generating Achievable DVH Objectives in IMRT Treatment Planning
    Wu, B.
    Ricchetti, F.
    Sanguineti, G.
    Kazhdan, M.
    Simari, P.
    Taylor, R.
    Jacques, R.
    McNutt, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S73 - S73
  • [10] Modeling of the external radiotherapy machine into radiotherapy treatment planning systems
    Theodorou, K
    Kappas, C
    Rosenwald, JC
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 1998, 14 (03): : 111 - 118