Latent heat storage integration into heat pump based heating systems for energy-efficient load shifting

被引:31
|
作者
Xu, Tianhao [1 ]
Humire, Emma Nyholm [1 ]
Chiu, Justin Ningwei [1 ]
Sawalha, Samer [1 ]
机构
[1] KTH Royal Inst Technol, Dept Energy Technol, S-10044 Stockholm, Sweden
关键词
Phase change material; Thermal energy storage; Heat pump; Load shifting; Energy use; Economic analysis; CO2; emissions; PHASE-CHANGE MATERIALS; THERMAL STORAGE; PERFORMANCE ASSESSMENT; DEMAND RESPONSE; BUILDINGS; BEHAVIOR; TARIFF; TANKS;
D O I
10.1016/j.enconman.2021.114042
中图分类号
O414.1 [热力学];
学科分类号
摘要
Integrating latent heat thermal energy storage (LHTES) units into building heating systems has been increasingly investigated as a heat load management technology. A conventional LHTES integration method for heat pump based heating systems is to connect the heat pump's condenser for charging the LHTES unit. This integrating layout however usually leads to increased electricity input to the heating system. To underline this issue and provide solutions, this paper presents three new LHTES integrating layouts where the LHTES unit is connected with the de-superheater of the main heat pump (Case 2), the condenser of a cascaded booster heat pump cycle (Case 3), or a combination of using both the de-superheater and the booster cycle (Case 4). In the context of a multi-family house in Stockholm, a quasi-steady state heating system model was developed to evaluate the new integrating layouts, which were benchmarked against the baseline heating system without storage (Case 0) and the conventional integrating layout using the main heat pump condenser (Case 1). Hourly electric power input to the heating system was modelled for calculating the performance indicators including the heating performance factor, the operational expense and justifiable capital expense, and the indirect CO2 emissions. Two load shifting strategies were simulated for an evaluation period of Week 1, 2019: 1) charge during off-peak hours (8 pm to 6 am) and 2) charge during daytime hours (10 am to 7 pm). The simulation results of the off-peak charging strategy show that, in Cases 2-4, the heating performance factor is 22%-26% higher than Case 1 and the operational expense can be reduced by 2%-5% as compared with Case 0. The savings in the operational expense can justify the capital expense of 11 k-25 k Swedish Krona (SEK) for the LHTES systems in Cases 2-4 assuming a 15-year operation. Furthermore, the advantage of using the daytime charging strategy is principally the mitigation of CO2 emissions, which is up to 14% lower than the off-peak charging strategy. In summary, higher energy efficiency for heating is validated in the three new proposed integration layouts (Cases 2-4) against the condenser charging layout.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] Energy efficient refrigeration system using latent heat storage, PCM
    Harun-Or-Rashid, Mohammad
    Hasan, Md Tawfique
    Alam, Towfiq Bin
    Hossain, Safayet
    [J]. International Journal of Thermofluids, 2024, 23
  • [42] Peak load shifting control on hot water supplied from district heating using latent heat storage system in apartment complex
    Lee, Daegyu
    Jeong, Hyo Jae
    Ji, Hyung Yong
    Park, Sung Yong
    Chung, Dong-Yeol
    Kang, Chaedong
    Kim, Kyung Min
    Park, Dongho
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2022, 34
  • [43] REQUIREMENT OF HEAT PUMP SYSTEM PERFORMANCE FOR AN ENERGY EFFICIENT SEAWATER-SOURCE HEAT PUMP DISTRICT HEATING SYSTEM
    Shu, Haiwen
    Lin Duanmu
    Li, Xiangli
    Zhu, Yingxin
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1644 - 1651
  • [44] Exergy analysis of latent heat storage systems with sensible heating and subcooling of PCM
    Ramayya, AV
    Ramesh, KN
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1998, 22 (05) : 411 - 426
  • [45] Model reduction and model predictive control of energy-efficient buildings for electrical heating load shifting
    Robillart, M.
    Schalbart, P.
    Chaplais, F.
    Peuportier, B.
    [J]. JOURNAL OF PROCESS CONTROL, 2019, 74 : 23 - 34
  • [46] Integration of variable refrigerant flow and heat pump desiccant systems for the heating season
    Aynur, Toga N.
    Hwang, Yunho
    Radermacher, Reinhard
    [J]. ENERGY AND BUILDINGS, 2010, 42 (04) : 468 - 476
  • [47] Innovative heat pump heating systems for district heating
    Hain, Claudia
    [J]. Euroheat and Power/Fernwarme International, 2020, 49 (1-2): : 14 - 16
  • [48] Heat source shifting in buildings supplied by district heating and exhaust air heat pump
    Kensby, J.
    Truschel, A.
    Dalenback, J. O.
    [J]. 15TH INTERNATIONAL SYMPOSIUM ON DISTRICT HEATING AND COOLING (DHC15-2016), 2017, 116 : 470 - 480
  • [49] EVALUATION OF THE EFFECTS OF WASTEWATER HEAT PUMP INTEGRATION INTO DISTRICT HEATING SYSTEMS BY SIMULATION
    Ivezic, Dejan D.
    Zivkovic, Marija A.
    Manic, Dimitrije J.
    Madzarevic, Aleksandar R.
    Pavlovic, Boban S.
    [J]. THERMAL SCIENCE, 2023, 27 (3B): : 2443 - 2454
  • [50] Air Source Heat Pump Energy Storage Heating System for Smart Building
    Chen Xing-chi
    Zhang Xiao-jing
    Zhao Hai
    [J]. PROCEEDINGS OF THE 28TH CHINESE CONTROL AND DECISION CONFERENCE (2016 CCDC), 2016, : 3635 - 3639