Latent heat storage integration into heat pump based heating systems for energy-efficient load shifting

被引:34
|
作者
Xu, Tianhao [1 ]
Humire, Emma Nyholm [1 ]
Chiu, Justin Ningwei [1 ]
Sawalha, Samer [1 ]
机构
[1] KTH Royal Inst Technol, Dept Energy Technol, S-10044 Stockholm, Sweden
关键词
Phase change material; Thermal energy storage; Heat pump; Load shifting; Energy use; Economic analysis; CO2; emissions; PHASE-CHANGE MATERIALS; THERMAL STORAGE; PERFORMANCE ASSESSMENT; DEMAND RESPONSE; BUILDINGS; BEHAVIOR; TARIFF; TANKS;
D O I
10.1016/j.enconman.2021.114042
中图分类号
O414.1 [热力学];
学科分类号
摘要
Integrating latent heat thermal energy storage (LHTES) units into building heating systems has been increasingly investigated as a heat load management technology. A conventional LHTES integration method for heat pump based heating systems is to connect the heat pump's condenser for charging the LHTES unit. This integrating layout however usually leads to increased electricity input to the heating system. To underline this issue and provide solutions, this paper presents three new LHTES integrating layouts where the LHTES unit is connected with the de-superheater of the main heat pump (Case 2), the condenser of a cascaded booster heat pump cycle (Case 3), or a combination of using both the de-superheater and the booster cycle (Case 4). In the context of a multi-family house in Stockholm, a quasi-steady state heating system model was developed to evaluate the new integrating layouts, which were benchmarked against the baseline heating system without storage (Case 0) and the conventional integrating layout using the main heat pump condenser (Case 1). Hourly electric power input to the heating system was modelled for calculating the performance indicators including the heating performance factor, the operational expense and justifiable capital expense, and the indirect CO2 emissions. Two load shifting strategies were simulated for an evaluation period of Week 1, 2019: 1) charge during off-peak hours (8 pm to 6 am) and 2) charge during daytime hours (10 am to 7 pm). The simulation results of the off-peak charging strategy show that, in Cases 2-4, the heating performance factor is 22%-26% higher than Case 1 and the operational expense can be reduced by 2%-5% as compared with Case 0. The savings in the operational expense can justify the capital expense of 11 k-25 k Swedish Krona (SEK) for the LHTES systems in Cases 2-4 assuming a 15-year operation. Furthermore, the advantage of using the daytime charging strategy is principally the mitigation of CO2 emissions, which is up to 14% lower than the off-peak charging strategy. In summary, higher energy efficiency for heating is validated in the three new proposed integration layouts (Cases 2-4) against the condenser charging layout.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] Thermodynamic performance of cascaded latent heat storage systems for building heating
    Lu, Shilei
    Lin, Quanyi
    Xu, Bowen
    Yue, Lu
    Feng, Wei
    ENERGY, 2023, 282
  • [32] Evaluation of ground-source heat pump combined latent heat storage system performance in greenhouse heating
    Benli, Hueseyin
    Durmus, Aydin
    ENERGY AND BUILDINGS, 2009, 41 (02) : 220 - 228
  • [33] Energetic performance analysis of a ground-source heat pump system with latent heat storage for a greenhouse heating
    Benli, Huseyin
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) : 581 - 589
  • [34] Compact Model of Latent Heat Thermal Storage for Its Integration in Multi-Energy Systems
    Colangelo, Alessandro
    Guelpa, Elisa
    Lanzini, Andrea
    Manco, Giulia
    Verda, Vittorio
    APPLIED SCIENCES-BASEL, 2020, 10 (24): : 1 - 14
  • [35] A DOMESTIC SOLAR/HEAT PUMP HEATING SYSTEM INCORPORATING LATENT AND STRATIFIED THERMAL STORAGE
    Trinkl, Christoph
    Zoerner, Wilfried
    Hanby, Vic
    ES2008: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 2, 2009, : 611 - 620
  • [36] Numerical simulation of solar assisted ground-source heat pump heating system with latent heat energy storage in severely cold area
    Han, Zongwei
    Zheng, Maoyu
    Kong, Fanhong
    Wang, Fang
    Li, Zhongjian
    Bai, Tian
    APPLIED THERMAL ENGINEERING, 2008, 28 (11-12) : 1427 - 1436
  • [37] Heating and energy storage characteristics of multi-split air source heat pump based on energy storage defrosting
    Yang, Bowen
    Dong, Jiankai
    Zhang, Long
    Song, Mengjie
    Jiang, Yiqiang
    Deng, Shiming
    APPLIED ENERGY, 2019, 238 : 303 - 310
  • [38] PERFORMANCE STUDY OF CASCADED LATENT HEAT STORAGE COUPLED WITH HEAT PUMP
    Tian L.
    Wang J.
    Zhao L.
    Wei C.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (03): : 571 - 578
  • [39] HEAT PUMP IN DISTRICT HEATING SYSTEMS
    LORENTZEN, G
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1977, 19 (12): : 34 - 34
  • [40] HEAT PUMP WATER HEATING SYSTEMS
    Stefanco, Martin
    Kosicanova, Danica
    ENERGY AND CLEAN TECHNOLOGIES, 2015, : 291 - 297