Latent heat storage integration into heat pump based heating systems for energy-efficient load shifting

被引:31
|
作者
Xu, Tianhao [1 ]
Humire, Emma Nyholm [1 ]
Chiu, Justin Ningwei [1 ]
Sawalha, Samer [1 ]
机构
[1] KTH Royal Inst Technol, Dept Energy Technol, S-10044 Stockholm, Sweden
关键词
Phase change material; Thermal energy storage; Heat pump; Load shifting; Energy use; Economic analysis; CO2; emissions; PHASE-CHANGE MATERIALS; THERMAL STORAGE; PERFORMANCE ASSESSMENT; DEMAND RESPONSE; BUILDINGS; BEHAVIOR; TARIFF; TANKS;
D O I
10.1016/j.enconman.2021.114042
中图分类号
O414.1 [热力学];
学科分类号
摘要
Integrating latent heat thermal energy storage (LHTES) units into building heating systems has been increasingly investigated as a heat load management technology. A conventional LHTES integration method for heat pump based heating systems is to connect the heat pump's condenser for charging the LHTES unit. This integrating layout however usually leads to increased electricity input to the heating system. To underline this issue and provide solutions, this paper presents three new LHTES integrating layouts where the LHTES unit is connected with the de-superheater of the main heat pump (Case 2), the condenser of a cascaded booster heat pump cycle (Case 3), or a combination of using both the de-superheater and the booster cycle (Case 4). In the context of a multi-family house in Stockholm, a quasi-steady state heating system model was developed to evaluate the new integrating layouts, which were benchmarked against the baseline heating system without storage (Case 0) and the conventional integrating layout using the main heat pump condenser (Case 1). Hourly electric power input to the heating system was modelled for calculating the performance indicators including the heating performance factor, the operational expense and justifiable capital expense, and the indirect CO2 emissions. Two load shifting strategies were simulated for an evaluation period of Week 1, 2019: 1) charge during off-peak hours (8 pm to 6 am) and 2) charge during daytime hours (10 am to 7 pm). The simulation results of the off-peak charging strategy show that, in Cases 2-4, the heating performance factor is 22%-26% higher than Case 1 and the operational expense can be reduced by 2%-5% as compared with Case 0. The savings in the operational expense can justify the capital expense of 11 k-25 k Swedish Krona (SEK) for the LHTES systems in Cases 2-4 assuming a 15-year operation. Furthermore, the advantage of using the daytime charging strategy is principally the mitigation of CO2 emissions, which is up to 14% lower than the off-peak charging strategy. In summary, higher energy efficiency for heating is validated in the three new proposed integration layouts (Cases 2-4) against the condenser charging layout.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Heat pump integrated with latent heat energy storage
    Xie, Baoshan
    Du, Shuai
    Wang, Ruzhu
    Kou, Xiaoxue
    Jiang, Jiatong
    Li, Chuanchang
    [J]. ENERGY & ENVIRONMENTAL SCIENCE, 2024, 17 (19) : 6943 - 6973
  • [2] Energy and economic performance of the heat pump integrated with latent heat thermal energy storage for peak demand shifting
    Jin, Xin
    Zheng, Siqian
    Huang, Gongsheng
    Lai, Alvin C. K.
    [J]. APPLIED THERMAL ENGINEERING, 2023, 218
  • [3] Perspective Ways of Energy-Efficient Modernization of Heat Supply Systems Based on Heat Pump Technologies
    Petrash, V. D.
    Baryshev, V. P.
    Shevchenko, L. F.
    Geraskina, E. A.
    Danichenko, N. V.
    [J]. PROBLEMELE ENERGETICII REGIONALE, 2022, (04): : 47 - 60
  • [4] Efficiency of heat pump systems with integrated latent heat storage
    Lukas, Benjamin
    Barton, Michael
    Schweigler, Christian
    [J]. 14TH IIR CONFERENCE ON PHASE CHANGE MATERIALS AND SLURRIES FOR REFRIGERATION AND AIR CONDITIONING, 2024, : 196 - 207
  • [5] Parametric analysis of system performance and cost of heating systems with heat pump and latent thermal energy storage
    Torbarina, Fran
    Lenic, Kristian
    Trp, Anica
    Kirincic, Mateo
    [J]. Applied Thermal Engineering, 2024,
  • [6] Optimal sizing of a thermoelectric heat pump (THP) for heating energy-efficient buildings
    Kim, Y. W.
    Ramousse, J.
    Fraisse, G.
    Dalicieux, P.
    Baranek, P.
    [J]. ENERGY AND BUILDINGS, 2014, 70 : 106 - 116
  • [7] Energy Efficient Integration of Heat Pumps into Solar District Heating Systems with Seasonal Thermal Energy Storage
    Marx, Roman
    Bauer, Dan
    Drueck, Harald
    [J]. 2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 2706 - 2715
  • [8] Techno-economic analysis of latent heat thermal energy storage integrated heat pump for indoor heating
    Shan, Lianying
    Martin, Andrew
    Chiu, Justin NingWei
    [J]. ENERGY, 2024, 298
  • [9] Development of an Energy Efficient Extrusion Factory employing a latent heat storage and a high temperature heat pump
    Zauner, Christoph
    Windholz, Bernd
    Lauermann, Michael
    Drexler-Schmid, Gerwin
    Leitgeb, Thomas
    [J]. APPLIED ENERGY, 2020, 259
  • [10] A simulation study on a solar heat pump heating system with seasonal latent heat storage
    Qi, Qi
    Deng, Shiming
    Jiang, Yiqiang
    [J]. SOLAR ENERGY, 2008, 82 (08) : 669 - 675