Co-extracted electrons and beam inhomogeneity in the large negative ion source SPIDER

被引:13
|
作者
Pimazzoni, Antonio [1 ,2 ]
Agostini, Matteo [2 ]
Brombin, Matteo [2 ]
Marconato, Nicolo [2 ,3 ]
Sartori, Emanuele [2 ]
Pasqualotto, Roberto [2 ]
Serianni, Gianluigi [2 ]
机构
[1] Viale Univ 2, INFNLNL, I-35020 Legnaro, Italy
[2] Consorzio RFX, Corso Stati Uniti 4, I-35127 Padua, Italy
[3] Univ Padua, Dipartimento Ingn Ind DII, I-35131 Padua, Italy
关键词
Electrons; Negative ions; SPIDER; Magnetic field; Beam inhomogeneity;
D O I
10.1016/j.fusengdes.2021.112440
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The SPIDER ion source has been designed to generate a current of H- ions up to 60 A and accelerate them up to 100 keV. In addition, the ratio between the co-extracted electrons and negative ions has to be below 1, and a beam inhomogeneity within 10 % has to be attained. A magnetic filter field is produced by a current flowing through the plasma electrode in the vertical direction with the aim of reducing electron temperature and density in the extraction region, so as to enhance the survival probability of H- ions while reducing the co-extracted electrons. Another strategy to reduce the co-extracted electrons is to apply a small bias voltage to the plasma grid with respect to the ion source body. In addition to this, a so-called bias plate is installed in the vicinity of the plasma grid, which can also be biased with respect to source body. However, the application of a bias voltage affects the beam inhomogeneity by modifying the ExB plasma drift within the ion source. Recently, the filter field configuration of SPIDER was modified so as to improve the plasma diffusion towards the extraction region. In addition, the voltage ratings of the bias power supplies were increased. Both these modifications permit to efficiently lower the electron co-extracted current. The present contribution describes such improvements while focusing on the effects they have on the beam inhomogeneity.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] High-current negative-ion beam acceleration with a large negative-ion source for large helical device-neutral beam injection system
    Takeiri, Y
    Osakabe, M
    Tsumori, K
    Oka, Y
    Kaneko, O
    Asano, E
    Kawamoto, T
    Akiyama, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 977 - 979
  • [32] High-current negative-ion beam acceleration with a large negative-ion source for large helical device-neutral beam injection system
    Takeiri, Y.
    Osakabe, M.
    Tsumori, K.
    Oka, Y.
    Kaneko, O.
    Asano, E.
    Kawamoto, T.
    Akiyama, R.
    Review of Scientific Instruments, 1998, 69 (2 pt 2):
  • [33] Development of the tomographic reconstruction technique of SPIDER negative ion beam
    Ugoletti, M.
    Agostini, M.
    FUSION ENGINEERING AND DESIGN, 2023, 189
  • [34] Final design of the diagnostic calorimeter for the negative ion source SPIDER
    Rizzolo, A.
    Tollin, M.
    Brombin, M.
    Cervaro, V.
    Dalla Palma, M.
    De Muri, M.
    Fasolo, D.
    Franchin, L.
    Peruzzo, S.
    Pimazzoni, A.
    Pasqualotto, R.
    Serianni, G.
    FUSION ENGINEERING AND DESIGN, 2017, 123 : 768 - 772
  • [35] Influence of the inhomogeneity of a focused photon beam on the stability of the ion current in an ion source with an effusion molecular beam
    Michalak, L
    Markowski, A
    Felinska, H
    VACUUM, 1999, 53 (3-4) : 465 - 472
  • [36] Negative ion beam source development in Europe
    Hemsworth, RS
    Bucalossi, J
    Desgranges, C
    Frank, P
    Fumelli, M
    Heinemann, B
    Hodgson, ER
    Jacquot, C
    Krause, W
    Massmann, P
    Michaut, C
    Ott, W
    Penningsfeld, HP
    Riz, D
    Simonin, A
    Speth, E
    Stabler, A
    Trainham, R
    Volmer, O
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS / PRODUCTION AND APPLICATION OF LIGHT NEGATIVE IONS, 1998, 439 : 237 - 243
  • [37] NEGATIVE MOLECULAR ION PARTICLE BEAM SOURCE
    LAVAN, MJ
    FUSION TECHNOLOGY, 1984, 6 (03): : 554 - 563
  • [38] BEAM EXTRACTION FROM A LARGE VACUUM-IMMERSED NEGATIVE-ION SOURCE
    TAKEIRI, Y
    OKA, Y
    KANEKO, O
    ANDO, A
    TSUMORI, K
    AKIYAMA, R
    KAWAMOTO, T
    KURODA, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (04): : 1198 - 1200
  • [39] Development of a large volume negative-ion source for ITER neutral beam injector
    Watanabe, K
    Amemiya, T
    Hanada, M
    Iga, T
    Imai, T
    Inoue, T
    Kashiwagi, M
    Kuriyama, M
    Morishita, T
    Okumura, Y
    Takayanagi, T
    Yamamoto, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02): : 1090 - 1092
  • [40] Properties of a Rubidium Isotope Ion Beam Extracted from a Laser Ion Source
    Tamura, Koji
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (06)