Comparison and uncertainties of standards for critical dimension atomic force microscope tip width calibration

被引:16
|
作者
Dixson, Ronald [1 ]
Orji, Ndubuisi G. [1 ]
机构
[1] NIST, 100 Bur Dr Stop 8212, Gaithersburg, MD 20899 USA
关键词
CD-AFM; metrology; CD; linewidth; reference measurement system; standards; calibration; traceability;
D O I
10.1117/12.714032
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Since the advent of critical-dimension atomic force microscopes (CD-AFMs) in the 90s, these tools have enjoyed growing acceptance in semiconductor manufacturing both for process development and to support in-line critical dimension (CD) metrology. The most common application of CD-AFMs has been to support critical-dimension scanning electron microscope (CD-SEM) and scatterometer metrology as a reference for tool matching or as a nondestructive alternative to transmission electron microscopy (TEM) and scanning electron microscopy (SEM) cross sections. For many years, CD-AFM users typically developed in-house reference standards for tip width calibration - often based on SEM or TEM cross sections. But the uncertainty of such standards was often large or unknown. Tip characterizer samples - which used a sharp ridge to calibrate the tip width - are commercially available. However, scanning such samples can result in tip damage, and the uncertainty of tip calibrations based on this method is at least 5 nm. In 2004, NIST, SEMATECH, and VLSI Standards collaborated on the development and release of single crystal critical dimension reference materials (SCCDRMs) to SEMATECH member companies. These specimens, which are fabricated using a lattice-plane-selective etch on (110) silicon, exhibit near vertical sidewalls and high uniformity and can be used to calibrate CD-AFM tip width to approximately 1 nm standard uncertainty (k = 1). Also in 2004, commercial critical dimension standards (CCDS) were introduced. Using CD-AFM instruments at both NIST and SEMATECH, we have performed a comparison of nominal 45 nm and 70 nm CCDS specimens with the SCCDRM calibration. Our observations show that these two independently performed calibrations are in agreement.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] The calibration of an atomic force microscope along three coordinates using a single certified dimension
    A. V. Rakov
    Yu. A. Novikov
    P. A. Todua
    Measurement Techniques, 2008, 51 : 475 - 479
  • [22] The calibration of an atomic force microscope along three coordinates using a single certified dimension
    Rakov, A. V.
    Novikov, Yu. A.
    Todua, P. A.
    MEASUREMENT TECHNIQUES, 2008, 51 (05) : 475 - 479
  • [23] Critical dimension atomic force microscope (CD-AFM) measurement of masks
    Muckenhirn, S
    Meyyappan, A
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XII, 1998, 3332 : 642 - 653
  • [24] Quantitative comparison of two independent lateral force calibration techniques for the atomic force microscope
    Barkley, Sarice S.
    Deng, Zhao
    Gates, Richard S.
    Reitsma, Mark G.
    Cannara, Rachel J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02):
  • [25] THERMOMECHANICAL WRITING WITH AN ATOMIC FORCE MICROSCOPE TIP
    MAMIN, HJ
    RUGAR, D
    APPLIED PHYSICS LETTERS, 1992, 61 (08) : 1003 - 1005
  • [26] TIP RECONSTRUCTION FOR THE ATOMIC-FORCE MICROSCOPE
    MILLER, R
    VESENKA, J
    HENDERSON, E
    SIAM JOURNAL ON APPLIED MATHEMATICS, 1995, 55 (05) : 1362 - 1371
  • [27] An atomic force microscope tip as a light source
    Lulevich, V
    Honig, C
    Ducker, WA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (12): : 1 - 5
  • [28] Real-time, interferometrically measuring atomic force microscope for direct calibration of standards
    Department of Mechanical Metrology, Natl. Res. Laboratory of Metrology, 1-1-4 Umezono, Tsukuba 305-8563, Japan
    不详
    Rev. Sci. Instrum., 8 (3362-3368):
  • [29] Real-time, interferometrically measuring atomic force microscope for direct calibration of standards
    Gonda, S
    Doi, T
    Kurosawa, T
    Tanimura, Y
    Hisata, N
    Yamagishi, T
    Fujimoto, H
    Yukawa, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (08): : 3362 - 3368
  • [30] Normal Force Calibration Method Used for Calibration of Atomic Force Microscope
    Ekwinska, M.
    Rymuza, Z.
    ACTA PHYSICA POLONICA A, 2009, 116 : S78 - S81