Analyzer-based phase-contrast imaging system using a micro focus x-ray source

被引:22
|
作者
Zhou, Wei [1 ]
Majidi, Keivan [2 ]
Brankov, Jovan G. [2 ]
机构
[1] IIT, BME Dept, Chicago, IL 60616 USA
[2] IIT, ECE Dept, Chicago, IL 60616 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2014年 / 85卷 / 08期
关键词
ASYMMETRICALLY CUT CRYSTALS; OPTICAL-ELEMENTS; DIFFRACTION; RADIOGRAPHY; TOMOGRAPHY;
D O I
10.1063/1.4890281
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Here we describe a new in-laboratory analyzer based phase contrast-imaging (ABI) instrument using a conventional X-ray tube source (CXS) aimed at bio-medical imaging applications. Phase contrast-imaging allows visualization of soft tissue details usually obscured in conventional X-ray imaging. The ABI system design and major features are described in detail. The key advantage of the presented system, over the few existing CXS ABI systems, is that it does not require high precision components, i.e., CXS, X-ray detector, and electro-mechanical components. To overcome a main problem introduced by these components, identified as temperature stability, the system components are kept at a constant temperature inside of three enclosures, thus minimizing the electrical and mechanical thermal drifts. This is achieved by using thermoelectric (Peltier) cooling/heating modules that are easy to control precisely. For CXS we utilized a microfocus X-ray source with tungsten (W) anode material. In addition the proposed system eliminates tungsten's multiple spectral lines by selecting monochromator crystal size appropriately therefore eliminating need for the costly mismatched, two-crystal monochromator. The system imaging was fine-tuned for tungsten K alpha(1) line with the energy of 59.3 keV since it has been shown to be of great clinical significance by a number of researchers at synchrotron facilities. In this way a laboratory system that can be used for evaluating and quantifying tissue properties, initially explored at synchrotron facilities, would be of great interest to a larger research community. To demonstrate the imaging capability of our instrument we use a chicken thigh tissue sample. (C) 2014 AIP Publishing LLC.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Phase contrast imaging with micro focus X-ray tube
    Shovkun, VY
    Kumakhov, MA
    X-Ray and Neutron Capillary Optics II, 2005, 5943 : 293 - 304
  • [32] Superimposed wavefront imaging of diffraction-enhanced x-rays: A method to achieve higher resolution in crystal analyzer-based x-ray phase-contrast imaging
    Sunaguchi, Naoki
    Yuasa, Tetsuya
    Shimao, Daisuke
    Ichihara, Shu
    Gupta, Rajiv
    Ando, Masami
    APPLIED PHYSICS LETTERS, 2023, 122 (12)
  • [33] Noise and analyzer-crystal angular position analysis for analyzer-based phase-contrast imaging
    Majidi, Keivan
    Li, Jun
    Muehleman, Carol
    Brankov, Jovan G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (08): : 1877 - 1897
  • [34] Optimal contrast for X-ray phase-contrast imaging
    College of Medical Instrument, University of Shanghai Science and Technology, Shanghai 200093, China
    不详
    Guangzi Xuebao, 2008, 6 (1217-1220):
  • [35] On analyzing of the contrast for X-ray phase-contrast imaging
    Liu, S.
    Zhang, X. L.
    Huang, Y.
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1168 - 1171
  • [36] Phase-Contrast Imaging in a Polychromatic X-ray Beam at a Laboratory Source
    Yu. S. Krivonosov
    V. E. Asadchikov
    A. V. Buzmakov
    Crystallography Reports, 2020, 65 : 503 - 507
  • [37] X-ray phase-contrast imaging at 100 keV on a conventional source
    Thuering, T.
    Abis, M.
    Wang, Z.
    David, C.
    Stampanoni, M.
    SCIENTIFIC REPORTS, 2014, 4
  • [38] X-ray phase-contrast imaging with an Inverse Compton Scattering source
    Endrizzi, M.
    Carpinelli, M.
    Delogu, P.
    Oliva, P.
    Golosio, B.
    Gureyev, T. E.
    Bottigli, U.
    Stefanini, A.
    6TH INTERNATIONAL CONFERENCE ON MEDICAL APPLICATIONS OF SYNCHROTRON RADIATION, 2010, 1266 : 39 - +
  • [39] Simulation of X-ray phase-contrast imaging with partially coherence source
    Institute of Optoelectronics Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
    不详
    Shenzhen Daxue Xuebao (Ligong Ban), 2007, 3 (261-266):
  • [40] Phase-Contrast Imaging in a Polychromatic X-ray Beam at a Laboratory Source
    Krivonosov, Yu. S.
    Asadchikov, V. E.
    Buzmakov, A. V.
    CRYSTALLOGRAPHY REPORTS, 2020, 65 (04) : 503 - 507