Analyzer-based phase-contrast imaging system using a micro focus x-ray source

被引:22
|
作者
Zhou, Wei [1 ]
Majidi, Keivan [2 ]
Brankov, Jovan G. [2 ]
机构
[1] IIT, BME Dept, Chicago, IL 60616 USA
[2] IIT, ECE Dept, Chicago, IL 60616 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2014年 / 85卷 / 08期
关键词
ASYMMETRICALLY CUT CRYSTALS; OPTICAL-ELEMENTS; DIFFRACTION; RADIOGRAPHY; TOMOGRAPHY;
D O I
10.1063/1.4890281
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Here we describe a new in-laboratory analyzer based phase contrast-imaging (ABI) instrument using a conventional X-ray tube source (CXS) aimed at bio-medical imaging applications. Phase contrast-imaging allows visualization of soft tissue details usually obscured in conventional X-ray imaging. The ABI system design and major features are described in detail. The key advantage of the presented system, over the few existing CXS ABI systems, is that it does not require high precision components, i.e., CXS, X-ray detector, and electro-mechanical components. To overcome a main problem introduced by these components, identified as temperature stability, the system components are kept at a constant temperature inside of three enclosures, thus minimizing the electrical and mechanical thermal drifts. This is achieved by using thermoelectric (Peltier) cooling/heating modules that are easy to control precisely. For CXS we utilized a microfocus X-ray source with tungsten (W) anode material. In addition the proposed system eliminates tungsten's multiple spectral lines by selecting monochromator crystal size appropriately therefore eliminating need for the costly mismatched, two-crystal monochromator. The system imaging was fine-tuned for tungsten K alpha(1) line with the energy of 59.3 keV since it has been shown to be of great clinical significance by a number of researchers at synchrotron facilities. In this way a laboratory system that can be used for evaluating and quantifying tissue properties, initially explored at synchrotron facilities, would be of great interest to a larger research community. To demonstrate the imaging capability of our instrument we use a chicken thigh tissue sample. (C) 2014 AIP Publishing LLC.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] In-line phase contrast imaging using a micro-focus X-ray source
    Yu Ai-Min
    Li Zheng
    Zhang Di
    Huang Zhi-Feng
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2006, 30 (11): : 1119 - 1122
  • [22] Application of variable-magnification X-ray Bragg magnifier to analyzer-based phase-contrast computed tomography
    Hirano, Keiichi
    Takahashi, Yumiko
    Sugiyama, Hiroshi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (04)
  • [23] Retrieval of multiple scattering contrast from x-ray analyzer-based imaging
    陈恒
    刘波
    赵立明
    任坤
    王志立
    Chinese Physics B, 2021, 30 (01) : 695 - 699
  • [24] Analyzer-based x-ray phase-contrast microscopy combining channel-cut and asymmetrically cut crystals
    Hoennicke, M. G.
    Cusatis, C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (11):
  • [25] Retrieval of multiple scattering contrast from x-ray analyzer-based imaging
    Chen, Heng
    Liu, Bo
    Zhao, Li-Ming
    Ren, Kun
    Wang, Zhi-Li
    CHINESE PHYSICS B, 2021, 30 (01)
  • [26] Hard X-ray phase-contrast imaging with a microfocus source
    Stevenson, AW
    Gao, D
    Gureyev, TE
    Pogany, A
    Wilkins, SW
    NONDESTRUCTIVE CHARACTERIZATION OF MATERIALS IX, 1999, 497 : 641 - 648
  • [27] X-ray phase-contrast imaging
    Endrizzi, Marco
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 88 - 98
  • [28] In vivo x-ray phase contrast analyzer-based imaging for longitudinal osteoarthritis studies in guinea pigs
    Coan, Paola
    Wagner, Andreas
    Bravin, Alberto
    Diemoz, Paul C.
    Keyrilainen, Jani
    Mollenhauer, Juergen
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (24): : 7649 - 7662
  • [29] Analyzer-based X-ray phase contrast imaging with four bounce Si(444) monochromators at ELETTRA
    Hoennicke, M. G.
    Rigon, L.
    Arfelli, F.
    Menk, R.-H.
    Cusatis, C.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2007, 204 (08): : 2740 - 2745
  • [30] Phase-contrast X-ray imaging based on interferometry
    Momose, A
    JOURNAL OF SYNCHROTRON RADIATION, 2002, 9 : 136 - 142