The effect of in situ/in vitro three-dimensional quantitative computed tomography image voxel size on the finite element model of human vertebral cancellous bone

被引:7
|
作者
Lu, Yongtao [1 ,2 ]
Engelke, Klaus [3 ]
Glueer, Claus-C
Morlock, Michael M. [1 ,4 ]
Huber, Gerd [1 ]
机构
[1] Hamburg Univ Technol TUHH, Inst Biomech, Hamburg, Germany
[2] Univ Sheffield, Dept Mech Engn, INSIGNEO Inst Silico Med, Sheffield S1 3JD, S Yorkshire, England
[3] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
[4] Univ Kiel, Dept Radiol & Neuroradiol, Sect Biomed Imaging, Kiel, Germany
关键词
Quantitative computed tomography image; finite element; voxel size; in situ; in vitro; vertebra; 3D QCT; CT; STRENGTH; MICROMECHANICS; ALENDRONATE; WOMEN; ELASTICITY; FRACTURES; PROTOCOL;
D O I
10.1177/0954411914558654
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Quantitative computed tomography-based finite element modeling technique is a promising clinical tool for the prediction of bone strength. However, quantitative computed tomography-based finite element models were created from image datasets with different image voxel sizes. The aim of this study was to investigate whether there is an influence of image voxel size on the finite element models. In all 12 thoracolumbar vertebrae were scanned prior to autopsy (in situ) using two different quantitative computed tomography scan protocols, which resulted in image datasets with two different voxel sizes (0.29x0.29x1.3mm(3) vs 0.18x0.18x0.6mm(3)). Eight of them were scanned after autopsy (in vitro) and the datasets were reconstructed with two voxel sizes (0.32x0.32x0.6mm(3) vs. 0.18x0.18x0.3mm(3)). Finite element models with cuboid volume of interest extracted from the vertebral cancellous part were created and inhomogeneous bilinear bone properties were defined. Axial compression was simulated. No effect of voxel size was detected on the apparent bone mineral density for both the in situ and in vitro cases. However, the apparent modulus and yield strength showed significant differences in the two voxel size group pairs (in situ and in vitro). In conclusion, the image voxel size may have to be considered when the finite element voxel modeling technique is used in clinical applications.
引用
收藏
页码:1208 / 1213
页数:6
相关论文
共 50 条
  • [31] Three-dimensional finite element modeling of the human external ear: Simulation study of the bone conduction occlusion effect
    Brummund, Martin K.
    Sgard, Franck
    Petit, Yvan
    Laville, Frederic
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2014, 135 (03): : 1433 - 1444
  • [32] Three-dimensional microstructure of human alveolar trabecular bone: a micro-computed tomography study
    Lee, Ji-Hyun
    Kim, Hee-Jin
    Yun, Jeong-Ho
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2017, 47 (01): : 20 - 29
  • [33] Three-dimensional finite element model of Shupe effect in fog fiber coil
    Key Laboratory of Opto-Electronics Information and Technical Science, Tianjin University, Tianjin 300072, China
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban), 2008, 5 (601-606):
  • [34] A three-dimensional finite element model for thermal effect of imperfect electric contacts
    Kim, BK
    Hsieh, KT
    Bostick, FX
    IEEE TRANSACTIONS ON MAGNETICS, 1999, 35 (01) : 170 - 174
  • [35] Biomechanical effects of bone cement volume on the endplates of augmented vertebral body: a three-dimensional finite element analysis
    Yan Liang
    Chang Zhen
    Xu Zhengwei
    Liu Tuanjiang
    He Baorong
    Hao Dingjun
    CHINESE MEDICAL JOURNAL, 2014, 127 (01) : 79 - 84
  • [36] Development of a Three-Dimensional Finite Element Model of Thoracolumbar Kyphotic Deformity following Vertebral Column Decancellation
    Wang, Tianhao
    Cai, Zhihua
    Zhao, Yongfei
    Zheng, Guoquan
    Wang, Wei
    Qi, Dengbin
    Song, Diyu
    Wang, Yan
    APPLIED BIONICS AND BIOMECHANICS, 2019, 2019
  • [37] Finite Element Method Based Three-Dimensional Thermal Tomography for Disease Diagnosis of Human Body
    Jin, Chao
    He, Zhi-Zhu
    Liu, Jing
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2016, 138 (10):
  • [38] Dynamic finite-size effect in the three-dimensional classical XY model
    Oh, SK
    Yoon, CN
    Chung, JS
    PHYSICAL REVIEW B, 1997, 56 (21) : 13677 - 13680
  • [39] Dynamic finite-size effect in the three-dimensional classical XY model
    Suhk, Kun Oh
    Chang No Yoon
    Chung, J. S.
    Physical Review B: Condensed Matter, 56 (21):
  • [40] Integrating in vitro, in situ and in vivo experimental data in a three-dimensional finite model of the cochlea.
    Kolston, PJ
    JOURNAL OF PHYSIOLOGY-LONDON, 1997, 504P : P56 - P57