Biomechanical effects of bone cement volume on the endplates of augmented vertebral body: a three-dimensional finite element analysis

被引:9
|
作者
Yan Liang [1 ]
Chang Zhen [1 ]
Xu Zhengwei [1 ]
Liu Tuanjiang [1 ]
He Baorong [2 ]
Hao Dingjun [1 ]
机构
[1] Xi An Jiao Tong Univ, Hong Hui Hosp, Dept Spine Surg, Coll Med, Xian 710054, Shaanxi, Peoples R China
[2] Shaanxi Prov Orthopaed Hosp, Dept Spine Surg, Xian 710054, Shaanxi, Peoples R China
关键词
osteoporosis; fracture; finite element analysis; vertebroplasty; endplate; stress distribution; PERCUTANEOUS VERTEBROPLASTY; FRACTURES; RISK;
D O I
10.3760/cma.j.issn.0366-6999.20131387
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Previous studies have suggested that percutaneous vertebroplasty might alter vertebral stress transfer, leading to adjacent vertebral failure. However, no three-dimensional finite element study so far accounted for the stress distributions on different cement volumes. The purpose of this study was to evaluate the stress distributions on the endplate under different loading conditions after augmentation with various volumes of bone cement. Methods L2-L3 motion segment data were obtained from CT scans of the lumbar spine from a cadaver of a young man who had no abnormal findings on roentgenograms. Three-dimensional model of L2-L3 was established using Mimics software, and finite element model of L2-L3 functional spinal unit (FSU) was established using Ansys10.0 software. For simulating percutaneous vertebral augmentation, polymethylmethacrylate (PMMA) was deposited into the bipedicle of the L2 vertebra. The percentage of PMMA volume varied between 15% and 30%. The stress distributions on the endplate of the augmented vertebral body were calculated under three different loading conditions. Results In general, the stress level monotonically increased with bone cement volume. Under each loading condition, the stress change on the L2 superior and inferior endplates in three kinds of finite element models shows monotonic increase. Compared with the stress-increasing region of the endplate, the central part of the L2 endplate was subject to the greatest stress under three kinds of loading conditions, especially on the superior endplate and under flexion. Conclusions The finite element models of FSU are useful to optimize the planning for vertebroplasty. The bone cement volume might have an influence on the endplate of the augmentation, especially the superior endplate. It should be noted that the optimization of bone cement volume is patient specific; the volume of the bone cement should be based on the size, body mineral density, and stiffness of the vertebrae of individual patients.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 50 条
  • [1] Biomechanical Effects of a Maxillary Implant in the Augmented Sinus: A Three-Dimensional Finite Element Analysis
    Huang, Heng-Li
    Fuh, Lih-Jyh
    Ko, Ching-Chang
    Hsu, Jui-Ting
    Chen, Chern-Chin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (03) : 455 - 462
  • [2] Biomechanical effects of cement distribution in the fractured area on osteoporotic vertebral compression fractures: a three-dimensional finite element analysis
    Liang, De
    Ye, Lin-Qiang
    Jiang, Xiao-Bing
    Yang, Pan
    Zhou, Guang-Quan
    Yao, Zhen-Song
    Zhang, Shun-Cong
    Yang, Zhi-Dong
    JOURNAL OF SURGICAL RESEARCH, 2015, 195 (01) : 246 - 256
  • [3] Finite element analysis of biomechanical effects of mineralized collagen modified bone cement on adjacent vertebral body after vertebroplasty
    Yang, Cunheng
    Wang, Fumin
    Huang, Xingxing
    Zhang, Hao
    Zhang, Meng
    Gao, Junxiao
    Shi, Shengbo
    Wang, Fuyang
    Yang, Fangjun
    Yu, Xiaobing
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [4] Biomechanical effects of different vertebral heights after augmentation of osteoporotic vertebral compression fracture: a three-dimensional finite element analysis
    Wen-Tao Zhao
    Da-Ping Qin
    Xiao-Gang Zhang
    Zhi-Peng Wang
    Zun Tong
    Journal of Orthopaedic Surgery and Research, 13
  • [5] Biomechanical effects of different vertebral heights after augmentation of osteoporotic vertebral compression fracture: a three-dimensional finite element analysis
    Zhao, Wen-Tao
    Qin, Da-Ping
    Zhang, Xiao-Gang
    Wang, Zhi-Peng
    Tong, Zun
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [6] Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement type
    Ha, Seung-Ryong
    JOURNAL OF ADVANCED PROSTHODONTICS, 2015, 7 (06): : 475 - 483
  • [7] Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement thickness
    Ha, Seung-Ryong
    Kim, Sung-Hun
    Lee, Jai-Bong
    Han, Jung-Suk
    Yeo, In-Sung
    Yoo, Seung-Hyun
    Kim, Hee-Kyung
    CERAMICS INTERNATIONAL, 2016, 42 (13) : 14928 - 14936
  • [8] Three-dimensional finite element simulations of vertebral body thermal treatment
    Ryan, TP
    Patel, SJ
    Morris, R
    Hoopes, PJ
    Bergeron, J
    Mahajan, R
    THERMAL TREATMENT OF TISSUE: ENERGY DELIVERY AND ASSESSMENT III, 2005, 5698 : 137 - 155
  • [9] Optimizing bone cement stiffness for vertebroplasty through biomechanical effects analysis based on patient-specific three-dimensional finite element modeling
    Yi Peng
    Xianping Du
    Lihua Huang
    Jinsong Li
    Ruisen Zhan
    Weiguo Wang
    Biaoxiang Xu
    Song Wu
    Cheng Peng
    Shijie Chen
    Medical & Biological Engineering & Computing, 2018, 56 : 2137 - 2150
  • [10] Optimizing bone cement stiffness for vertebroplasty through biomechanical effects analysis based on patient-specific three-dimensional finite element modeling
    Peng, Yi
    Du, Xianping
    Huang, Lihua
    Li, Jinsong
    Zhan, Ruisen
    Wang, Weiguo
    Xu, Biaoxiang
    Wu, Song
    Peng, Cheng
    Chen, Shijie
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (11) : 2137 - 2150