Using a 3D diode array system to verify 3D dose distribution

被引:1
|
作者
Xue, T. [1 ]
机构
[1] St Lukes Hosp, Bethlehem, PA USA
关键词
D O I
10.1118/1.2761161
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We have been used a 3D diode array to verify 3D dose distributions from IMRT plans, and SRS plans using conical arcs or dynamical arcs. Some of the results are reported here. We are also going to study the possibility of using this diode array for routine QA of the treatment machine and the treatment planning system. Method and Materials: IMRT plans are developed on Varian Eclipse, and delivered on Varian Trilogy treatment unit by using sliding window technique. The SRS plans are developed on a BrainLab IPlan Dose, and delivered on the Trilogy. The 3D diode array is the Delta4 system from Scandidos. Delta4 has 1069 type Si diodes on two planes in a cylindrical PMMA phantom. In the treatment planning systems, a patient plan is copied to the phantom, and recalculated. The plan and dose distribution are transferred to the Delta4 system by using DICOM RT. In the Delta4 software, the planned dose and measured dose are compared by using 2D isodose display, profile comparisons, percentage dose deviation, and DTA and Gamma index. Results: We have used this method to verify 61 IMRT plans. The average percent diodes with deviation of 5% or less is 84.5%; the average distance to agreement (DTA) of 3mm or less is 86.7%. The average Gamma Index (5% and 3mm) of 1.0 or less is 91.8%. We have also used this system to verify the isocenter dose of BrainLab SRS plans, each using a cone from 7.5 mm to 30 mm with 180 degree arc. The average absolute difference between measurement and plan isocenter dose is 1.8%. Conclusion: The 3D diode system is a good tool to verify 3D dose distribution. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2502 / 2502
页数:1
相关论文
共 50 条
  • [1] Using a 3D Diode Array System to Perform Routine IMRT Machine QA
    Penn, S. Tafon
    Xue, T.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2765 - +
  • [2] On Rotational Measurements with the ArcCHECK 3D Diode Array
    Feygelman, V.
    Zhang, G.
    Stevens, C.
    Nelms, B.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [3] DEVELOPMENT OF 3D PHASED ARRAY SYSTEM "3D FOCUS-UT"
    Baba, A.
    Kono, N.
    Kitazawa, S.
    Adachi, Y.
    Odakura, M.
    Kikuchi, O.
    [J]. REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 29A AND 29B, 2010, 1211 : 941 - +
  • [4] Reconstructing 3D proton dose distribution using ionoacoustics
    van Dongen, K. W. A.
    de Blecourt, J.
    Lens, E.
    Schaart, D. R.
    Vos, F. M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (22):
  • [5] 3D DOSE DISTRIBUTION OF GYNECOLOGICAL APPLICATORS
    LING, C
    SPIRO, I
    BENNETT, D
    RUSTGI, S
    YORKE, E
    GASKILL, J
    KUBIATOWICZ, D
    WINDORSKI, D
    [J]. MEDICAL PHYSICS, 1982, 9 (04) : 625 - 625
  • [6] 3D DOSE VERIFICATION USING TOMOTHERAPY CT DETECTOR ARRAY
    Sheng, Ke
    Jones, Ryan
    Yang, Wensha
    Saraiya, Siddharth
    Schneider, Bernard
    Chen, Quan
    Sobering, Geoff
    Olivera, Gustavo
    Read, Paul
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (02): : 1013 - 1020
  • [7] Investigation on the 3D Memristor Array Architecture for 3D Reservoir Computing System Implementation
    Sun, Wenxuan
    Yu, Jie
    Dong, Danian
    Zheng, Xu
    Lai, Jinru
    Fan, Shaoyang
    Wang, Hongzhou
    Gao, Jianfeng
    Liu, Junfeng
    Xu, Xiaoxin
    [J]. IEEE ELECTRON DEVICE LETTERS, 2024, 45 (08) : 1445 - 1448
  • [8] Architecture of 3D Memory Cell Array on 3D IC
    Lee, Sang-Yun
    Park, Junil
    [J]. 2012 4TH IEEE INTERNATIONAL MEMORY WORKSHOP (IMW), 2012,
  • [9] Fabrication and characterization of 3D scaffold using 3D plotting system
    Lee, Jun-Hee
    Park, Su-A
    Park, KoEun
    Kim, Jae-Hyun
    Kim, Kyung-Shik
    Lee, Jihye
    Kim, WanDoo
    [J]. CHINESE SCIENCE BULLETIN, 2010, 55 (01): : 94 - 98
  • [10] Fabrication and characterization of 3D scaffold using 3D plotting system
    LEE JunHee
    PARK SuA
    PARK KoEun
    KIM JaeHyun
    KIM KyungShik
    LEE Jihye
    Kim WanDoo
    [J]. Chinese Science Bulletin, 2010, 55 (01) : 94 - 98