DEVELOPMENT OF 3D PHASED ARRAY SYSTEM "3D FOCUS-UT"

被引:5
|
作者
Baba, A. [1 ]
Kono, N. [1 ]
Kitazawa, S. [1 ]
Adachi, Y. [2 ]
Odakura, M. [3 ]
Kikuchi, O. [4 ]
机构
[1] Hitachi Ltd, Energy & Environm Syst Lab, Tarrytown, NY 10591 USA
[2] Hitachi Ltd, Thermal & Hydroelect Syst QA Dept, Tarrytown, NY 10591 USA
[3] Hitachi GE Nucl Energy Ltd, Nucl Plant Serv QA Dept, Tarrytown, NY 10591 USA
[4] Hitachi Engn & Serv Ltd, Inspect Engn Div, Tarrytown, NY 10591 USA
关键词
Ultrasonic Inspection; Three Dimensional Phased Array; Phased Array System;
D O I
10.1063/1.3362531
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Ultrasonic phased array inspection systems have been used the in various industrial fields recently. For instance, power plants have used these systems to maintain their reliability. The phased array is advantageous because it improves efficiency by imaging the inside of the test subject. This inspection image is obtained by electronic scanning of a focused ultrasonic beam using a phased array sensor. We have developed a 3-dimensional volume inspection technology to make further efficiency and accuracy improvements in ultrasonic inspections. This study presents the innovative 3D phased array inspection system "3D Focus-UT" for 3D volume inspection. This system employs (I) a 3D ray-trace simulator to set up the delay time for the elements in the array sensor and the delay pattern for 3D volume scanning; (2) high sensitivity phased array equipment that has a 256ch pulsar/receiver to drive/receive a 2D matrix array transducer simultaneously; and (3) high-speed 3D data processing software. The software converts 3D volumetric inspection data into 3D voxel data in order to display 3D inspection images. The images can be used to evaluate the crack location and crack size. Some results of 3D volume inspection obtained by the 3D Focus-UT are presented here.
引用
收藏
页码:941 / +
页数:2
相关论文
共 50 条
  • [1] ANIMATION FOCUS - TO 3D OR NOT TO 3D
    HARBISON, D
    [J]. COMPUTER GRAPHICS WORLD, 1987, 10 (07) : 55 - 56
  • [2] 3D Printable Multilayer Phased Array Design
    Yu, Xiaoju
    Liang, Min
    Shemelya, Corey
    Wicker, Ryan
    MacDonaldand, Eric
    Xin, Hao
    [J]. 2015 USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM) PROCEEDINGS, 2015, : 351 - 351
  • [3] A spiral 2D phased array for 3D imaging
    Sumanaweera, TS
    Schwartz, J
    Napolitano, D
    [J]. 1999 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 1999, : 1271 - 1274
  • [4] Selection of adaptive threshold for phased array 3D sonar
    Yuan, Long-Tao
    Tian, Xiang
    Chen, Yao-Wu
    [J]. Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2013, 43 (03): : 841 - 848
  • [5] 3D WELD VISUALIZATION USING MANUAL PHASED ARRAY
    Berke, Michael
    Renzel, Peter
    [J]. 10TH EUROPEAN CONFERENCE ON NON-DESTRUCTIVE TESTING 2010 (ECNDT), VOLS 1-5, 2010, : 448 - 457
  • [6] Using a 3D diode array system to verify 3D dose distribution
    Xue, T.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2502 - 2502
  • [7] WeldNet: From 3D phased-array ultrasound scans to 3D geometrical models of welds and defects
    Provencal, Etienne
    Laperriere, Luc
    [J]. CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2022, 71 (01) : 445 - 448
  • [8] Investigation on the 3D Memristor Array Architecture for 3D Reservoir Computing System Implementation
    Sun, Wenxuan
    Yu, Jie
    Dong, Danian
    Zheng, Xu
    Lai, Jinru
    Fan, Shaoyang
    Wang, Hongzhou
    Gao, Jianfeng
    Liu, Junfeng
    Xu, Xiaoxin
    [J]. IEEE ELECTRON DEVICE LETTERS, 2024, 45 (08) : 1445 - 1448
  • [9] 3D Vector Velocity Estimation using a 2D Phased Array
    Pihl, Michael Johannes
    Jensen, Jorgen Arendt
    [J]. 2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 430 - 433
  • [10] Architecture of 3D Memory Cell Array on 3D IC
    Lee, Sang-Yun
    Park, Junil
    [J]. 2012 4TH IEEE INTERNATIONAL MEMORY WORKSHOP (IMW), 2012,