Anatomically shaped internal carotid artery aneurysm in vitro model for flow analysis to evaluate stent effect

被引:1
|
作者
Baráth, K
Cassot, F
Rüfenacht, DA
Fasel, JHD
机构
[1] Univ Hosp Geneva, Dept Radiol, Geneva, Switzerland
[2] CHU Purpan, Funct Neuroimaging Lab, Toulouse, France
[3] CHU Purpan, INSERM, U455, Toulouse, France
[4] Med Univ Geneva, Dept Anat, Geneva, Switzerland
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Stent implantation alone might not be sufficient to produce definitive treatment of cerebral aneurysms. Therefore, extended experimental work is needed to improve results. We show the feasibility of using an in vitro anatomically shaped elastic model for flow evaluation before and after stent implantation. METHODS: Based on human vascular casting, an anatomic elastic internal carotid artery model, including an aneurysm on the supraclinoid portion, was manufactured. The model was connected to a circulatory loop to simulate physiological flow. After visualization of the flow by using glass particles and laser sheet translumination, the digitally recorded data were transferred for computer analysis. Intra-saccular flow pattern changes and the vortex velocity reduction induced by the stent were investigated qualitatively and quantitatively. RESULTS: The distal neck of the aneurysm behaved as a flow divider. Therefore, it was directly exposed to the hemodynamic stress. Inside the sac, a well-defined vortex formed and progressed along the wall toward the proximal neck. After stent implantation this pattern changed significantly; the vortex appeared more dispersed and its residence time increased. The velocity reduction was 32%. Velocity peak was observed close to the distal neck in both cases. CONCLUSION: In vitro anatomic elastic models are feasible for flow evaluation with laser sheet translumination. In our model, stent implantation resulted in hemodynamic changes that might favor the exclusion of the aneurysm from the circulation and can prevent regrowth of the aneurysmal sac.
引用
收藏
页码:1750 / 1759
页数:10
相关论文
共 50 条
  • [21] Recurrence of an internal carotid artery aneurysm after complete exclusion by a Willis covered stent
    Tian, Zhongbin
    Mu, Shiqing
    Li, Wenqiang
    Zhu, Wei
    Zhang, Ying
    Yang, Xinjian
    Liu, Jian
    INTERVENTIONAL NEURORADIOLOGY, 2019, 25 (06) : 688 - 691
  • [22] Stent-graft treatment of a large internal carotid artery vein graft aneurysm
    Powell, RJ
    Rzucidlo, EM
    Schermerhorn, ML
    JOURNAL OF VASCULAR SURGERY, 2003, 37 (06) : 1310 - 1313
  • [23] Treatment of internal carotid artery thrombosis: an in vitro model
    Chant, H
    Fearn, S
    McHugh, D
    Ashleigh, R
    McCollum, CN
    BRITISH JOURNAL OF SURGERY, 1998, 85 (05) : 707 - 708
  • [24] Developing an in vitro validated 3D in silico internal carotid artery sidewall aneurysm model
    Yi, Hang
    Yang, Zifeng
    Johnson, Mark
    Bramlage, Luke
    Ludwig, Bryan
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [25] Commentary: Effect of Carotid Siphon Anatomy on Aneurysm Occlusion After Flow Diversion for Treatment of Internal Carotid Artery Aneurysms
    Srinivasan, Visish M.
    Kan, Peter
    OPERATIVE NEUROSURGERY, 2019, 17 (02) : E45 - E46
  • [27] In vitro flow diversion effect of the ReSolv stent with the shelf technique in a bifurcation aneurysm model
    Belanger, Brooke L.
    Morrish, Rosalie
    McClarty, Davis
    Barnstable, Colette
    Muir, Warren
    Ghazizadeh, Soheil
    Eesa, Muneer
    Fiorella, David
    Wong, John H.
    Sadasivan, Chandar
    Mitha, Alim P.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024, 16 (03) : 296 - 301
  • [28] An in vitro analysis of a carotid artery stent with a protective porous membrane
    Müller-Hülsbeck, S
    Hüsler, EJ
    Schaffner, SR
    Jahnke, T
    Glass, C
    Wenke, R
    Heller, M
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (11) : 1295 - 1305
  • [29] Flow-Diverter Stent for an Unruptured Aneurysm at the Junction of the Internal Carotid Artery and Persistent Primitive Trigeminal Artery: Case Report and Literature Review
    Sato, Hirotaka
    Haraguchi, Koichi
    Takahashi, Yashuhiro
    Ohtaki, Shunya
    Shimizu, Tadakazu
    Matsuura, Nobuyuki
    Ogane, Kazumi
    Ito, Takeo
    WORLD NEUROSURGERY, 2019, 132 : 329 - 332
  • [30] Intermediate analysis of magnesium alloy covered stent for a lateral aneurysm model in the rabbit common carotid artery
    Cui, Hong-kai
    Li, Fen-Bao
    Guo, Ying-Chang
    Zhao, Yong-Li
    Yan, Rui-Fang
    Wang, Wu
    Li, Yong-Dong
    Wang, Yong-Li
    Yuan, Guang-Yin
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3694 - 3702