Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?

被引:22
|
作者
Figueroa, Jose [1 ,2 ,3 ]
Pablo Guarachi, Juan [3 ]
Matas, Jose [3 ,4 ,5 ]
Arnander, Magnus [6 ]
Orrego, Mario [1 ,3 ,5 ]
机构
[1] Hosp Mil Santiago, Knee Surg Unit, Av Alcalde Fernando Castillo Velasco 9100, Santiago, Chile
[2] Clin Davila, Knee Surg Unit, Avenida Recoleta 464, Santiago, Chile
[3] Univ Los Andes, Sch Med, Dept Orthoped, Mons Alvaro Portillo 12-455, Santiago, Chile
[4] Clin Meds, Knee Surg Unit, Condes, Las Condes 13-451, Santiago, Chile
[5] Clin Univ Los Andes, Knee Surg Unit, Santiago, Chile
[6] St George Hosp, Dept Orthopaed Surg, Blackshaw Rd, London SW17 0QT, England
关键词
Total knee arthroplasty; Computed tomography; Rotation; Malrotation; Accuracy; Reliability; PATIENT SATISFACTION; REPLACEMENT; REVISION; MALROTATION; ALIGNMENT; RELIABILITY;
D O I
10.1007/s00264-015-2917-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Computed tomography (CT) is widely used to assess component rotation in patients with poor results after total knee arthroplasty (TKA). The purpose of this study was to simultaneously determine the accuracy and reliability of CT in measuring TKA component rotation. TKA components were implanted in dry-bone models and assigned to two groups. The first group (n = 7) had variable femoral component rotations, and the second group (n = 6) had variable tibial tray rotations. CT images were then used to assess component rotation. Accuracy of CT rotational assessment was determined by mean difference, in degrees, between implanted component rotation and CT-measured rotation. Intraclass correlation coefficient (ICC) was applied to determine intra-observer and inter-observer reliability. Femoral component accuracy showed a mean difference of 2.5A degrees and the tibial tray a mean difference of 3.2A degrees. There was good intra- and inter-observer reliability for both components, with a femoral ICC of 0.8 and 0.76, and tibial ICC of 0.68 and 0.65, respectively. CT rotational assessment accuracy can differ from true component rotation by approximately 3A degrees for each component. It does, however, have good inter- and intra-observer reliability.
引用
收藏
页码:709 / 714
页数:6
相关论文
共 50 条
  • [41] Lateral retinacular release as a function of femoral component rotation in total knee arthroplasty
    Sodha, S
    Kim, J
    McGuire, KJ
    Lonner, JH
    Lotke, PA
    JOURNAL OF ARTHROPLASTY, 2004, 19 (04): : 459 - 463
  • [42] Reliability of frames of reference used for tibial component rotation in total knee arthroplasty
    Page, Stephen R.
    Deakin, Angela H.
    Payne, Anthony P.
    Picard, Frederic
    COMPUTER AIDED SURGERY, 2011, 16 (02) : 86 - 92
  • [43] Correlation of tibial component size and rotation with outcomes after total knee arthroplasty
    Klasan, Antonio
    Twiggs, Joshua G.
    Fritsch, Brett A.
    Miles, Brad P.
    Heyse, Thomas J.
    Solomon, Michael
    Parker, David A.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (11) : 1819 - 1824
  • [44] EFFECT OF COMPONENT FIXATION METHOD ON OSTEOLYSIS IN TOTAL KNEE ARTHROPLASTY
    EZZET, KA
    GARCIA, R
    BARRACK, RL
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (321) : 86 - 91
  • [45] Method for selection of femoral component in total knee arthroplasty (tka)
    Dawie van den Heever
    Cornie Scheffer
    Pieter Erasmus
    Edwin Dillon
    Australasian Physical & Engineering Sciences in Medicine, 2011, 34 : 23 - 30
  • [46] Method for selection of femoral component in total knee arthroplasty (tka)
    van den Heever, Dawie
    Scheffer, Cornie
    Erasmus, Pieter
    Dillon, Edwin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (01) : 23 - 30
  • [47] A simple radiographic method to predict femoral component rotation in gap balancing total knee arthroplasty - moving towards a concept of individual femoral component rotation
    von Knoch, Fabian
    Ilmer, Christian
    Harder, Laurent
    Naal, Florian
    von Knoch, Marius
    Preiss, Stefan
    SWISS MEDICAL WEEKLY, 2012, 142 : S33 - S33
  • [48] Accuracy and Validity of Sharma’s Venn Diagram Method for Assessment of Tibial Component Rotation in Total Knee Arthroplasty
    Mrinal Sharma
    Bharat Dhanjani
    Akshay Raj Upadhyaya
    Indian Journal of Orthopaedics, 2022, 56 : 1291 - 1302
  • [49] Accuracy and Validity of Sharma's Venn Diagram Method for Assessment of Tibial Component Rotation in Total Knee Arthroplasty
    Sharma, Mrinal
    Dhanjani, Bharat
    Upadhyaya, Akshay Raj
    INDIAN JOURNAL OF ORTHOPAEDICS, 2022, 56 (07) : 1291 - 1302
  • [50] Component fracture in total knee arthroplasty
    Clarke, HD
    Trousdale, RT
    KNEE, 1999, 6 (04): : 261 - 267