Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?

被引:22
|
作者
Figueroa, Jose [1 ,2 ,3 ]
Pablo Guarachi, Juan [3 ]
Matas, Jose [3 ,4 ,5 ]
Arnander, Magnus [6 ]
Orrego, Mario [1 ,3 ,5 ]
机构
[1] Hosp Mil Santiago, Knee Surg Unit, Av Alcalde Fernando Castillo Velasco 9100, Santiago, Chile
[2] Clin Davila, Knee Surg Unit, Avenida Recoleta 464, Santiago, Chile
[3] Univ Los Andes, Sch Med, Dept Orthoped, Mons Alvaro Portillo 12-455, Santiago, Chile
[4] Clin Meds, Knee Surg Unit, Condes, Las Condes 13-451, Santiago, Chile
[5] Clin Univ Los Andes, Knee Surg Unit, Santiago, Chile
[6] St George Hosp, Dept Orthopaed Surg, Blackshaw Rd, London SW17 0QT, England
关键词
Total knee arthroplasty; Computed tomography; Rotation; Malrotation; Accuracy; Reliability; PATIENT SATISFACTION; REPLACEMENT; REVISION; MALROTATION; ALIGNMENT; RELIABILITY;
D O I
10.1007/s00264-015-2917-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Computed tomography (CT) is widely used to assess component rotation in patients with poor results after total knee arthroplasty (TKA). The purpose of this study was to simultaneously determine the accuracy and reliability of CT in measuring TKA component rotation. TKA components were implanted in dry-bone models and assigned to two groups. The first group (n = 7) had variable femoral component rotations, and the second group (n = 6) had variable tibial tray rotations. CT images were then used to assess component rotation. Accuracy of CT rotational assessment was determined by mean difference, in degrees, between implanted component rotation and CT-measured rotation. Intraclass correlation coefficient (ICC) was applied to determine intra-observer and inter-observer reliability. Femoral component accuracy showed a mean difference of 2.5A degrees and the tibial tray a mean difference of 3.2A degrees. There was good intra- and inter-observer reliability for both components, with a femoral ICC of 0.8 and 0.76, and tibial ICC of 0.68 and 0.65, respectively. CT rotational assessment accuracy can differ from true component rotation by approximately 3A degrees for each component. It does, however, have good inter- and intra-observer reliability.
引用
收藏
页码:709 / 714
页数:6
相关论文
共 50 条
  • [31] Femoral component rotation in mobile-bearing total knee arthroplasty
    Boldt, J. G.
    Stiehl, J. B.
    Munzinger, U.
    Beverland, D.
    Keblish, P. A.
    KNEE, 2006, 13 (04): : 284 - 289
  • [32] Femoral component rotation and Laurin angle after total knee arthroplasty
    Classen, Tim
    Wegner, Alexander
    Muller, Ralf-Dietrich
    Von Knoch, Marius
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (01): : 69 - 73
  • [33] Femoral Component Axial Rotation in the Gap-Balancing Approach to Total Knee Arthroplasty: Measurement by Computed Tomography (vol 33, pg 1222, 2018)
    Aihara, Andre Y.
    Cardoso, Fabiano N.
    Debiex, Pedro
    Castro, Antonio M.
    Luzo, Marcus V. M.
    Fernandes, Artur R. C.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (04): : 816 - 817
  • [34] Measuring External Rotation of the Fibula and Fibular Length in Bilateral Computed Tomography Scans: How Reliable Is This Method?
    Penning, Diederick
    Molendijk, Juul
    Halm, Jens A.
    Schepers, Tim
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2024, 38 (04) : 205 - 209
  • [35] Imaging of symptomatic total knee arthroplasty with cone beam computed tomography
    Jaroma, Antti
    Suomalainen, Juha-Sampo
    Niemitukia, Lea
    Soininvaara, Tarja
    Saio, Jari
    Kroger, Heikki
    ACTA RADIOLOGICA, 2018, 59 (12) : 1500 - 1507
  • [36] Computed tomography analysis of knee pose and geometry before and after total knee arthroplasty
    Ho, K. C. T.
    Saevarsson, S. K.
    Ramm, H.
    Lieck, R.
    Zachow, S.
    Sharma, G. B.
    Rex, E. L.
    Amiri, S.
    Wu, B. C. Y.
    Leumann, A.
    Anglin, C.
    JOURNAL OF BIOMECHANICS, 2012, 45 (13) : 2215 - 2221
  • [37] Computed tomography measurement of the accuracy of component version in total hip arthroplasty
    Wines, Andrew P.
    McNicol, David
    JOURNAL OF ARTHROPLASTY, 2006, 21 (05): : 696 - 701
  • [38] The impact of knee anatomy on femoral component rotation and flexion gap balance in total knee arthroplasty
    von Knoch, Fabian
    Ilmer, Christian
    Harder, Laurent
    von Knoch, Marius
    Preiss, Stefan
    SWISS MEDICAL WEEKLY, 2012, 142 : S32 - S32
  • [39] The Ranawat Award Paper - Optimizing femoral component rotation in total knee arthroplasty
    Miller, MC
    Berger, RA
    Petrella, AJ
    Karmas, A
    Rubash, HE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 38 - 45
  • [40] Correlation of tibial component size and rotation with outcomes after total knee arthroplasty
    Antonio Klasan
    Joshua G. Twiggs
    Brett A. Fritsch
    Brad P. Miles
    Thomas J. Heyse
    Michael Solomon
    David A. Parker
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1819 - 1824