Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?

被引:22
|
作者
Figueroa, Jose [1 ,2 ,3 ]
Pablo Guarachi, Juan [3 ]
Matas, Jose [3 ,4 ,5 ]
Arnander, Magnus [6 ]
Orrego, Mario [1 ,3 ,5 ]
机构
[1] Hosp Mil Santiago, Knee Surg Unit, Av Alcalde Fernando Castillo Velasco 9100, Santiago, Chile
[2] Clin Davila, Knee Surg Unit, Avenida Recoleta 464, Santiago, Chile
[3] Univ Los Andes, Sch Med, Dept Orthoped, Mons Alvaro Portillo 12-455, Santiago, Chile
[4] Clin Meds, Knee Surg Unit, Condes, Las Condes 13-451, Santiago, Chile
[5] Clin Univ Los Andes, Knee Surg Unit, Santiago, Chile
[6] St George Hosp, Dept Orthopaed Surg, Blackshaw Rd, London SW17 0QT, England
关键词
Total knee arthroplasty; Computed tomography; Rotation; Malrotation; Accuracy; Reliability; PATIENT SATISFACTION; REPLACEMENT; REVISION; MALROTATION; ALIGNMENT; RELIABILITY;
D O I
10.1007/s00264-015-2917-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Computed tomography (CT) is widely used to assess component rotation in patients with poor results after total knee arthroplasty (TKA). The purpose of this study was to simultaneously determine the accuracy and reliability of CT in measuring TKA component rotation. TKA components were implanted in dry-bone models and assigned to two groups. The first group (n = 7) had variable femoral component rotations, and the second group (n = 6) had variable tibial tray rotations. CT images were then used to assess component rotation. Accuracy of CT rotational assessment was determined by mean difference, in degrees, between implanted component rotation and CT-measured rotation. Intraclass correlation coefficient (ICC) was applied to determine intra-observer and inter-observer reliability. Femoral component accuracy showed a mean difference of 2.5A degrees and the tibial tray a mean difference of 3.2A degrees. There was good intra- and inter-observer reliability for both components, with a femoral ICC of 0.8 and 0.76, and tibial ICC of 0.68 and 0.65, respectively. CT rotational assessment accuracy can differ from true component rotation by approximately 3A degrees for each component. It does, however, have good inter- and intra-observer reliability.
引用
收藏
页码:709 / 714
页数:6
相关论文
共 50 条
  • [1] Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?
    José Figueroa
    Juan Pablo Guarachi
    José Matas
    Magnus Arnander
    Mario Orrego
    International Orthopaedics, 2016, 40 : 709 - 714
  • [2] The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation
    Jazrawi, LM
    Birdzell, L
    Kummer, FJ
    Di Cesare, PE
    JOURNAL OF ARTHROPLASTY, 2000, 15 (06): : 761 - 766
  • [3] Measuring Tibial Component Rotation Following Total Knee Arthroplasty: What Is the Best Method?
    Saffi, Mustafa
    Spangehl, Mark J.
    Clarke, Henry D.
    Young, Simon W.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (07): : S355 - S360
  • [4] Metal Artifact Reduction Dual-Energy CT as an Accurate and Reliable Method for Measuring Total Knee Arthroplasty Femoral Component Rotation Compared to Conventional CT
    Park, Chankue
    Lee, Sang-Min
    Seo, Jae Seung
    Kim, Tae Woo
    Rhee, Seung Joon
    Jeong, Hee Seok
    JOURNAL OF KNEE SURGERY, 2023, 36 (09) : 988 - 994
  • [5] Computed tomographic evaluation of femoral component rotation in total knee arthroplasty
    Shrinand V. Vaidya
    Rajesh M. Gadhiya
    Vaibhav Bagaria
    Amar S. Ranawat
    Chitranjan S. Ranawat
    Indian Journal of Orthopaedics, 2013, 47 : 40 - 44
  • [6] Computed tomographic evaluation of femoral component rotation in total knee arthroplasty
    Vaidya, Shrinand V.
    Gadhiya, Rajesh M.
    Bagaria, Vaibhav
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (01) : 40 - 44
  • [7] A computed-tomography-scan-based template to place the femoral component in accurate rotation with respect to the surgical epicondylar axis in total knee arthroplasty
    Oshima, Yasushi
    Lizawa, Norishige
    Kataoka, Tatsunori
    Majima, Tokifumi
    Takai, Shinro
    KNEE, 2018, 25 (01): : 195 - 202
  • [8] How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography: a systematic review
    De Valk, Eduard J.
    Noorduyn, Julia C. A.
    Mutsaerts, Eduard L. A. R.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (11) : 3517 - 3528
  • [9] Femoral Component Axial Rotation in the Gap-Balancing Approach to Total Knee Arthroplasty: Measurement by Computed Tomography
    Aihara, Andre Y.
    Cardoso, Fabiano N.
    Debiex, Pedro
    Castro, Antonio M.
    Luzo, Marcus V. M.
    Fernandes, Artur R. C.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (04): : 1222 - +
  • [10] How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography: a systematic review
    Eduard J. De Valk
    Julia C. A. Noorduyn
    Eduard L. A. R. Mutsaerts
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 3517 - 3528