Validity and Reliability of a New Karate-Specific Aerobic Field Test for Karatekas

被引:32
|
作者
Tabben, Montassar [1 ]
Coquart, Jeremy [1 ]
Chaabene, Helmi [2 ]
Franchini, Emerson [3 ]
Chamari, Karim [4 ]
Tourny, Claire [1 ]
机构
[1] Univ Rouen, Ctr Study Phys & Sports Act Transformat, CETAPS EA 3832, Mont St Aignan, France
[2] Natl Ctr Med & Sci Sports, Tunisian Res Lab Sports Performance Optimizat, Tunis, Tunisia
[3] Univ Sao Paulo, Sch Phys Educ & Sport, Sao Paulo, Brazil
[4] Orthoped & Sports Med Hosp, Athlete Hlth & Performance Res Ctr ASPETAR, Doha, Qatar
关键词
maximal test; martial art; specific evaluation; fitness; SOCCER PLAYERS; PHYSIOLOGICAL-RESPONSES; SPORTS-MEDICINE; OXYGEN-UPTAKE; COSMED K2; EXERCISE; CAPACITY; SCIENCE; SCORES;
D O I
10.1123/ijspp.2013-0465
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose: This study determined the validity and reliability of a new specific field test that was based on the scientific data from the latest research. Methods: Seventeen international-level karatekas participated in the study: 14 men (age 24.1 +/- 4.6 y, body mass 65.7 +/- 10.8 kg) and 3 women (age 19 +/- 3.6 y, body mass 54.1 +/- 0.9 kg). All performed the new karate-specific test (KST) 2 times (test and retest sessions were carried out on separated occasions 1 wk apart). Thirteen men also performed a laboratory test to assess maximal oxygen uptake (VO2max,).Results: Test-retest results showed the KST to be reliable. Peak oxygen uptake (VO2peak), peak heart rate (HRpeak, blood lactate concentration, rating of perceived exertion, and time to exhaustion (TE) did not display a difference between the test and the retest. The SEM and ICC for relative and absolute VO2peak and TB were <5% and >.90, respectively. Significant correlations were found between VO2peak (mL.kg(-1). min(-1)) and TB measured from the KST (r =.71, 95 %CI 0.35-0.88, P <.0001). There was also no significant difference between VO2peak measured from the KST and VO2max recorded from the cycle-ergometer laboratory test (55.1 +/- 4.8 vs 53.2 +/- 6.6 mL .kg(-1). min(-1), respectively; t = -1.85, df = 12, P =.08, d(z)= 0.51 [small]). The Bland and Altman analyses reported a mean difference (bias) the 95% limits of agreement of 1.9 +/- 7.35 mL .kg(-1). min(-1). Conclusions: This study showed that the new KST test, with effort patterns replicating real karate combat sessions, can be considered a valid and reliable karate-specific field test for assessing karatekas' endurance fitness.
引用
收藏
页码:953 / 958
页数:6
相关论文
共 50 条
  • [31] VALIDITY AND RELIABILITY OF A NEW TEST OF UPPER BODY POWER
    Clemons, James M.
    Campbell, Brian
    Jeansonne, Chris
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2010, 24 (06) : 1559 - 1565
  • [32] Reliability, Validity and Sensitivity of a New Test of Soccer Performance
    Jeukendrup, Asker E.
    Currell, Kevin
    Conway, Steve
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S238 - S238
  • [33] A NEW TEST FOR HEMISPHERICITY - THE EXAMINATION OF ITS VALIDITY AND RELIABILITY
    OGURA, H
    HATTA, T
    JAPANESE JOURNAL OF PSYCHOLOGY, 1983, 54 (01): : 36 - 42
  • [34] Retesting The Validity Of A Specific Field Test For Judo Training
    Santos, Luis
    Gonzalez, Vicente
    Iscar, Marta
    Brime, Juan I.
    Fernandez-Rio, Javier
    Rodriguez, Blanca
    Angeles Montoliu, Ma
    JOURNAL OF HUMAN KINETICS, 2011, 29 : 141 - 150
  • [35] The Modified-Athletic Shoulder Test: Reliability and validity of a new on-field assessment tool
    Tooth, Camille
    Forthomme, Benedicte
    Croisier, Jean-Louis
    Gofflot, Amandine
    Bornheim, Stephen
    Schwartz, Cedric
    PHYSICAL THERAPY IN SPORT, 2022, 58 : 8 - 15
  • [36] Reliability and validity of measures taken during the Chester step test to predict aerobic power and to prescribe aerobic exercise
    Buckley, JP
    Sim, J
    Eston, RG
    Hession, R
    Fox, R
    BRITISH JOURNAL OF SPORTS MEDICINE, 2004, 38 (02) : 197 - 205
  • [37] Reliability and validity of a submaximal treadmill test to estimate aerobic capacity in women with rheumatic disease
    Minor, MA
    Johnson, JC
    JOURNAL OF RHEUMATOLOGY, 1996, 23 (09) : 1517 - 1523
  • [38] Validity and Reliability of the 45-15 Test for Aerobic Fitness in Young Soccer Players
    Castagna, Carlo
    Iellamo, Ferdinand
    Impellizzeri, Franco Maria
    Manzi, Vincenzo
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2014, 9 (03) : 525 - 531
  • [39] VALIDITY AND RELIABILITY OF AN ON-COURT FITNESS TEST FOR ASSESSING AND MONITORING AEROBIC FITNESS IN SQUASH
    James, Carl
    Vallejo, Florencio Tenllado
    Kantebeen, Melvin
    Farra, Saro
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2019, 33 (05) : 1400 - 1407
  • [40] Wheelchair Shuttle Test for Assessing Aerobic Fitness in Youth With Spina Bifida: Validity and Reliability
    Bloemen, Manon A. T.
    de Groot, Janke F.
    Backx, Frank J. G.
    Benner, Joyce
    Kruitwagen, Cas L. J. J.
    Takken, Tim
    PHYSICAL THERAPY, 2017, 97 (10): : 1020 - 1029