VALIDITY AND RELIABILITY OF A NEW TEST OF UPPER BODY POWER

被引:37
|
作者
Clemons, James M. [1 ]
Campbell, Brian [1 ]
Jeansonne, Chris [1 ]
机构
[1] Univ Louisiana Lafayette, Dept Kinesiol, Human Performance Lab, Lafayette, LA 70506 USA
关键词
bench press power; medicine ball put; upper body power; BENCH PRESS; GRIP WIDTH; STRENGTH; ACCELERATION; PERFORMANCE; PLAYERS; WOMEN;
D O I
10.1519/JSC.0b013e3181dad222
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Clemons, JM, Campbell, B, and Jeansonne, C. Validity and reliability of a new test of upper body power. J Strength Cond Res 24(6): 1559-1565, 2010-The purpose of this study was to determine the concurrent validity of a new bench press power (BPP) test using the medicine ball put (MBP) as the criterion measure. Forty-three college-age students (19 males and 24 females) participated in the study. Participants performed 1 repetition at maximum speed using 61.4 kg (males) and 25 kg (females), at a grip width of 130% of biacromial breadth. Timing was initiated manually at the moment of upward bar movement and stopped automatically as the bar broke an infrared beam 0.3 m above the chest. All tests were conducted within 2 weeks. There was 1 practice session for the BPP test and 2 separate testing sessions, one for BPP and the other for the MBP. Three BPP trials were separated by >= 2 minutes of passive recovery. Individual scores were the average of the second and third tests and were expressed in Watts: Power = Bar mass kg.9.81-0.3m/s. Medicine ball put scores were the average distance the ball was thrown on the second and third trials from a sitting position on a 45 degrees recumbent weight bench. Concurrent validity was determined by conducting a Pearson Correlation on BPP and MBP scores at an alpha level of 0.05: males, r = 0.861; females, r = 0.79, (p < 0.000). In addition, results of an Intraclass R indicated excellent test-retest reliability for both males and females for BPP and the MBP (p < 0.05). The conclusion was that the BPP test is a logically and concurrently valid method for coaches and trainers to use in assessing upper body power for both college-age males and females.
引用
收藏
页码:1559 / 1565
页数:7
相关论文
共 50 条
  • [1] The "upper limb rotation test": Reliability and validity study of a new upper extremity physical performance test
    Decleve, Ph
    Attar, T.
    Benameur, T.
    Gaspar, V
    Van Cant, J.
    Cools, Ann M.
    PHYSICAL THERAPY IN SPORT, 2020, 42 : 118 - 123
  • [2] VALIDITY AND RELIABILITY OF A NEW STAIR SPRINTING TEST OF EXPLOSIVE POWER
    Clemons, Jim
    Harrison, Medgar
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2008, 22 (05) : 1578 - 1583
  • [3] Criterion Validity and Reliability of a New Medicine Ball Rotational Power Test
    Hardy, Sean G. J.
    Stelzer-Hiller, Oscar W.
    Edwards, Kate M.
    Freeston, Jonathan
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2025, 39 (03) : e429 - e435
  • [4] Reliability and Validity of a New Test for Muscle Power Evaluation of Stroke Patients
    Fujita, Toshifumi
    Iwata, Manabu
    Fukuda, Michitaka
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2011, 23 (02) : 259 - 263
  • [5] FACTORIAL VALIDITY OF UPPER BODY POWER TESTS
    Sola, Branimir
    Mandaric, Marin
    Sola, Matilda
    Kontic, Goran
    8TH INTERNATIONAL SCIENTIFIC CONFERENCE ON KINESIOLOGY, 2017, : 659 - 662
  • [6] Validity and Reliability of the Seated Medicine Ball Throw as a Measure of Upper Body Power in Older Women
    Strand, Keri L.
    Ly, Anna S.
    Barry, Sarah S.
    Liscano, Jose A.
    Trebotich, Thomas L.
    Martin-Diala, Chimaobim
    Martin, Erick
    Signorile, Joseph F.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2023, 37 (04) : 902 - 908
  • [7] RELIABILITY AND VALIDITY OF A NEW REPEATED AGILITY TEST AS A MEASURE OF ANAEROBIC AND EXPLOSIVE POWER
    Haj-Sassi, Radhouane
    Dardouri, Wajdi
    Gharbi, Zied
    Chaouachi, Anis
    Mansour, Hamda
    Rabhi, Ahmed
    Mahfoudhi, Mohamed-Elhedi
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2011, 25 (02) : 472 - 480
  • [8] Reliability and Validity of a New Variable-Power Performance Test in Road Cyclists
    Sharma, Avish P.
    Elliott, Adrian D.
    Bentley, David J.
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2015, 10 (03) : 278 - 284
  • [9] The validity and reliability of a test of lower body musculotendinous stiffness
    Walshe, AD
    Wilson, GJ
    Murphy, AJ
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1996, 73 (3-4): : 332 - 339
  • [10] Korean Upper Extremity Performance Test for the Elderly: Validity and Reliability
    Lee, Chang Dae
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 2018, 72 (04):