Prediction of hypotension during spinal anesthesia for cesarean section and its relation to the effect of crystalloid or colloid preload

被引:32
|
作者
Dahlgren, G. [1 ]
Granath, F.
Wessel, H.
Irestedt, L.
机构
[1] Karolinska Univ Hosp, Dept Anesthesia & Intens Care, Clin Epidemiol Unit, Dept Med, SE-17176 Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Gynecol & Obstet, SE-17176 Stockholm, Sweden
关键词
cesarean section; spinal anesthesia; supine stress test; prediction; hypotension; colloid;
D O I
10.1016/j.ijoa.2006.10.006
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: If parturients prone to develop caval compression in the supine position were identified before delivery, this might be a method of predicting hypotension during caesarean section under spinal anesthesia. Colloid preloading is superior to crystalloid in reducing the risk for spinal anesthetic-induced hypotension. It is postulated that parturients preoperatively susceptible to the supine position would benefit the most from colloid preloading. Methods: Fifty-five healthy parturients scheduled for elective cesarean section under spinal anesthesia were preoperatively investigated with a supine stress test with measurement of maternal heart rate, blood pressure, right uterine artery pulsatility index and symptoms in the left lateral and supine positions. They were then randomized to receive a colloid or crystalloid preload before anesthesia. Results: The stress test was positive, indicating a reduced tolerance to the supine position, in 36%. The sensitivity and specificity of the stress test for clinically significant hypotension (symptomatic hypotension) for patients randomized to the crystalloid group (n = 25) were 69 and 92% respectively. Patients with a positive stress test receiving a crystalloid preload showed a higher frequency of hypotension compared to all other groups, 90% vs. 33%, (P = 0.003) and also a greater need for ephedrine, mean dose (SD): 20.0 (9.7) vs. 8.4 (9.0) mg (P = 0.002). Conclusions: Pregnant women with a positive preoperative supine stress test constitute a subset at increased risk for clinically significant hypotension during cesarean delivery under spinal anesthesia. These women seem more likely to benefit from prophylactic colloid solution than women with a negative stress test. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:128 / 134
页数:7
相关论文
共 50 条
  • [31] Effect of eNOS genetic polymorphism on hypotension and treatment response during spinal anesthesia for cesarean section
    Landau, R
    Negron, M
    Blouin, J
    Scott, JA
    Smiley, RM
    [J]. ANESTHESIOLOGY, 2004, 100 (05) : B33 - B33
  • [32] MANAGEMENT OF HYPOTENSION FOLLOWING SPINAL ANESTHESIA FOR CESAREAN SECTION
    LABARTINO, L
    MOJDEHI, E
    MAURO, AL
    [J]. ANESTHESIA AND ANALGESIA CURRENT RESEARCHES, 1966, 45 (02): : 179 - +
  • [33] Effect of different crystalloid preload volumes combined with prophylactic norepinephrine infusion on inferior vena cava collapsibility index and post-spinal anesthesia hypotension during cesarean section: a randomized controlled trial
    Qin, R.
    Chen, Y.
    Zhu, Y.
    Zhang, Y.
    Ma, G.
    Guo, L.
    Xue, W.
    He, L.
    Ma, S.
    Ni, X.
    [J]. INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2022, 52
  • [34] The Effects of Crystalloid and Colloid Preload on Cardiac Output in the Parturient Undergoing Planned Cesarean Delivery Under Spinal Anesthesia: A Randomized Trial
    Tamilselvan, Perumal
    Fernando, Roshan
    Bray, Johanna
    Sodhi, Manisha
    Columb, Malachy
    [J]. ANESTHESIA AND ANALGESIA, 2009, 109 (06): : 1916 - 1921
  • [35] CRYSTALLOID OR COLLOID FOR GOAL-DIRECTED FLUID THERAPY IN CESAREAN SECTION UNDER COMBINED SPINAL EPIDURAL ANESTHESIA
    Sun, N.
    Yu, T.
    Xu, H.
    Liu, Y.
    Zhao, P.
    [J]. ANESTHESIA AND ANALGESIA, 2016, 123 : 283 - 284
  • [36] Prevention of spinal anaesthesia induced hypotension in the elderly: Comparison between crystalloid, colloid and NO preload solution
    Buggy, DJ
    OBrien, D
    Higgins, P
    Moran, C
    ODonovan, F
    McCarroll, M
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 : A239 - A239
  • [37] Hypotension induced by spinal anesthesia during cesarean section Current treatment concepts
    Fantin, R.
    Ortner, C. M.
    Klein, K. U.
    Putz, G.
    Rhofer, D.
    Jochberger, S.
    [J]. ANAESTHESIST, 2020, 69 (04): : 254 - 261
  • [38] Perfusion Index and its Relation to Hypotension of Parturients Undergoing Cesarean Section Under Spinal Anesthesia: An Observational Study
    Shuai, Fei
    Jia, Junxiang
    Lin, Peng
    Liao, Yicong
    Xie, Yuemei
    [J]. INTERNATIONAL JOURNAL OF PHARMACOLOGY, 2024, 20 (02) : 209 - 216
  • [39] COLLOID VERSUS CRYSTALLOID TO PRELOAD BEFORE SPINAL ANESTHESIA AT TRANSURETHRAL RESECTION OF THE PROSTATE: A RANDOMIZED TRIAL
    Ovezov, A. M.
    Gorbachev, D. V.
    Ovcharova, J. V.
    Nad'kina, E. D.
    Markov, A. G.
    [J]. INTENSIVE CARE MEDICINE, 2012, 38 : S152 - S152
  • [40] A randomized trial of crystalloid versus colloid solution for prevention of hypotension during spinal or low-dose combined spinal-epidural anesthesia for elective cesarean delivery
    Ko, J-S.
    Kim, C-S.
    Cho, H-S.
    Choi, D-H.
    [J]. INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2007, 16 (01) : 8 - 12