Prediction of hypotension during spinal anesthesia for cesarean section and its relation to the effect of crystalloid or colloid preload

被引:32
|
作者
Dahlgren, G. [1 ]
Granath, F.
Wessel, H.
Irestedt, L.
机构
[1] Karolinska Univ Hosp, Dept Anesthesia & Intens Care, Clin Epidemiol Unit, Dept Med, SE-17176 Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Gynecol & Obstet, SE-17176 Stockholm, Sweden
关键词
cesarean section; spinal anesthesia; supine stress test; prediction; hypotension; colloid;
D O I
10.1016/j.ijoa.2006.10.006
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: If parturients prone to develop caval compression in the supine position were identified before delivery, this might be a method of predicting hypotension during caesarean section under spinal anesthesia. Colloid preloading is superior to crystalloid in reducing the risk for spinal anesthetic-induced hypotension. It is postulated that parturients preoperatively susceptible to the supine position would benefit the most from colloid preloading. Methods: Fifty-five healthy parturients scheduled for elective cesarean section under spinal anesthesia were preoperatively investigated with a supine stress test with measurement of maternal heart rate, blood pressure, right uterine artery pulsatility index and symptoms in the left lateral and supine positions. They were then randomized to receive a colloid or crystalloid preload before anesthesia. Results: The stress test was positive, indicating a reduced tolerance to the supine position, in 36%. The sensitivity and specificity of the stress test for clinically significant hypotension (symptomatic hypotension) for patients randomized to the crystalloid group (n = 25) were 69 and 92% respectively. Patients with a positive stress test receiving a crystalloid preload showed a higher frequency of hypotension compared to all other groups, 90% vs. 33%, (P = 0.003) and also a greater need for ephedrine, mean dose (SD): 20.0 (9.7) vs. 8.4 (9.0) mg (P = 0.002). Conclusions: Pregnant women with a positive preoperative supine stress test constitute a subset at increased risk for clinically significant hypotension during cesarean delivery under spinal anesthesia. These women seem more likely to benefit from prophylactic colloid solution than women with a negative stress test. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:128 / 134
页数:7
相关论文
共 50 条
  • [21] Reflections on hypotension during Cesarean section under spinal anesthesia: do we need to use colloid
    Weeks, S
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2000, 47 (07): : 608 - 610
  • [22] Crystalloid, colloid or no preload for prevention of spinal anaesthesia induced hypotension in the elderly.
    Buggy, DJ
    OBrien, D
    Higgins, P
    Moran, C
    ODonovan, F
    [J]. ANESTHESIOLOGY, 1996, 85 (3A) : A110 - A110
  • [23] The effect of posture on hypotension after spinal anesthesia for cesarean section
    Levin, A
    Datta, S
    Segal, S
    [J]. ANESTHESIOLOGY, 1998,
  • [24] Vasopressors for hypotension in spinal anesthesia for cesarean section
    Biava, Anna Maria
    Cipriani, Gianni
    Malja, Endrit
    Bilotta, Federico
    [J]. JOURNAL OF ANESTHESIA, 2024,
  • [25] Spinal hypotension associated with cesarean section - Will preload ever work?
    Rout, C
    Rocke, DA
    [J]. ANESTHESIOLOGY, 1999, 91 (06) : 1565 - 1567
  • [26] Maternal cardiac output changes following crystalloid or colloid cohydration with spinal anesthesia for elective cesarean section
    McDonald, S.
    Fernando, R.
    Ashpole, K.
    Columb, M.
    [J]. ANESTHESIOLOGY, 2007, 106 (05) : B50 - B50
  • [27] Preloading vs. postloading of colloid for the prevention of hypotension after spinal anesthesia for cesarean section
    Brummel, C
    Mercier, F
    Fuller, A
    Mathusamy, A
    Lipman, S
    Cohen, SE
    Riley, ET
    [J]. ANESTHESIOLOGY, 2004, 100 (05) : B33 - B33
  • [28] Effect of injection rate on hypotension associated with spinal anesthesia for cesarean section
    Simon, L
    Boulay, G
    Ziane, AF
    Noblesse, E
    Mathiot, JL
    Toubas, MF
    Hamaza, J
    [J]. INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2000, 9 (01) : 10 - 14
  • [29] Effects of isothermic crystalloid coload on maternal hypotension and fetal outcomes during spinal anesthesia for cesarean section: A randomized controlled trial
    Canturk, Mehmet
    Canturk, Fusun Karbancioglu
    [J]. TAIWANESE JOURNAL OF OBSTETRICS & GYNECOLOGY, 2019, 58 (03): : 428 - 433
  • [30] A Randomized Trial Comparing Colloid Preload to Coload During Spinal Anesthesia for Elective Cesarean Delivery
    Siddik-Sayyid, Sahar M.
    Nasr, Viviane G.
    Taha, Samar K.
    Zbeide, Reine A.
    Shehade, Jules-Marie A.
    Al Alami, Ashir A.
    Mokadem, Farah H.
    Abdallah, Faraj W.
    Baraka, Anis S.
    Aouad, Marie T.
    [J]. ANESTHESIA AND ANALGESIA, 2009, 109 (04): : 1219 - 1224