Fault Location in Neutral Non-effectively Grounded Distribution Systems Using Phase Current and Line-to-line Voltage

被引:8
|
作者
Tang, Jinrui [1 ]
Yin, Xianggen [1 ]
Wen, Minghao [1 ]
Zhang, Zhe [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
distribution systems; fault location; non-effectively grounding; traveling wave; NETWORKS; SIGNALS;
D O I
10.1080/15325008.2014.933367
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A scheme of single-line-to-ground fault location in neutral non-effectively grounded distribution systems is proposed in this article. The characteristics of phase current traveling waves and line-to-line voltage traveling waves are analyzed. The wavelet transform technique is used to extract the information of the arrival times, polarities, and amplitudes of the recorded traveling waves. The fault location scheme can simultaneously realize faulty feeder identification, fault section location, and fault position location even if only two-phase current transformers are installed in the Phases A and C and feeder terminal units only to provide line-to-line voltage information. The effectiveness and practicability of the proposed scheme have been verified by PSCAD/EMTDC simulation results.
引用
收藏
页码:1371 / 1385
页数:15
相关论文
共 50 条
  • [41] Estimation of the Line-to-Line Voltage Phases in MV Distribution Faults using Transformer Inrush Currents
    Garcia, Antonio
    Biscarri, Felix
    Leon, Carlos
    Personal, Enrique
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [42] A load flow method using line-to-line voltages for ungrounded distribution power systems
    Kang Jun
    Ma Weiming
    Fu Lijun
    Ma Fan
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 1205 - 1210
  • [43] Characteristics of phase current and its application in fault section location in noneffectively grounded distribution systems
    Tang, Jinrui
    Yin, Xianggen
    Zhang, Zhe
    Sensors and Transducers, 2014, 165 (02): : 176 - 181
  • [44] Analyses of the connection mode of anti-resonance using 4 PT in the neutral non-effectively grounded system
    Wang, Shi-Xu
    Li, Fa-Zhang
    Zhang, Guo-Hong
    Lian, Jing-Bin
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2011, 39 (12): : 151 - 154
  • [45] Central or local compensation of earth-fault currents in non-effectively earthed distribution systems
    Guldbrand, A.
    Samuelsson, O.
    2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 1129 - 1134
  • [46] Mitigation of line and neutral current harmonics in three-phase distribution systems
    Ashari, M
    Nayar, CV
    Islam, S
    IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5, 2000, : 3166 - 3171
  • [47] An Adaptive Inverse Time-delay Characteristic of the Zero-sequence Overvoltage Protection for Identification of the Single-Phase Earth Fault in the Neutral Non-Effectively Grounded Power Systems
    Lin, Xiangning
    Zhao, Zhimin
    Bo, Zhiqian
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 1076 - +
  • [48] Single-Line-to-Ground Fault Location in Resonant Grounded Systems Based on Fault Distortions
    Chen, Yougen
    Yin, Junbo
    Li, Zhiyong
    Wei, Renyong
    IEEE ACCESS, 2021, 9 (09): : 34325 - 34337
  • [49] Single-Phase to Ground Fault Line Identification for Medium Voltage Islanded Microgrids With Neutral Ineffectively Grounded Modes
    He, Lili
    Li, Yang
    Chu, Xu
    Shuai, Zhikang
    Peng, Yelun
    Shen, Z. John
    IEEE TRANSACTIONS ON SMART GRID, 2022, 13 (06) : 4312 - 4326
  • [50] Fault location on a transmission line using synchronized voltage measurements
    Brahma, SM
    Girgis, AA
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (04) : 1619 - 1622