Purpose: The largest in vivo dosimetry study for interstitial brachytherapy yet examined was performed using new radiophotoluminescence glass dosimeters (RPLGDs). Based on the results, a dose prescription technique achieving high reproducibility and eliminating large hyperdose sleeves was studied. Methods and Materials: For 61 head-and-neck cancer patients who underwent high-dose-rate interstitial brachytherapy, new RPLGDs were used for an in vivo study. The Paris System was used for implant. An arbitrary isodose surface was selected for dose prescription. Locations of 83 dosimeters were categorized as on target (n = 52) or on nontarget organ (n = 31) and were also scaled according to % basal dose isodose surface (% BDIS). Compatibility (measured dose/calculated dose) was analyzed according to location. The hyperdose sleeve was assessed in terms of prescription surface expressed in % BDIS. Results: The spread of compatibilities was larger for on nontarget organ (1.06+/-0.32) than for on target (0.87 +/- 0.17, p = 0.01). Within on target RPLGDs, compatibility on < 95 % BDIS (0.95+/- 0.10) was better than on greater than or equal to95 % BDIS (0.84+/-0.18, p = 0.02). The number of patients with diameter of hyperdose sleeve greater than or equal to10 mm was increased with a dose prescription to <77% BDIS (p = 0.046). For nontarget organs, the maximal positive deviation was 84% of the calculated dose. Conclusions: Dose prescription is recommended to >77% and <95% BDIS for reproducibility and elimination of excessive hyperdose sleeve. For organs at risk, radioprotection should be considered even when calculated dose seems sufficiently low. Further development of planning software is necessary to prevent overestimation. (C) 2005 Elsevier Inc.
引用
收藏
页码:945 / 953
页数:9
相关论文
共 50 条
  • [21] Prostate cancer boost using high-dose-rate brachytherapy: Impact of the learning curve on the dosimetry
    Benhaim, C.
    Chand, M-E
    Gal, J.
    Hijazi, H.
    Gautier, M.
    Hannoun-Levi, J-M
    CANCER RADIOTHERAPIE, 2014, 18 (07): : 659 - 665
  • [22] Urethral dosimetry and toxicity with high-dose-rate interstitial brachytherapy for vaginal cancer
    Rajagopalan, Malolan S.
    Kannan, Neeta
    Kim, Hayeon
    Houser, Christopher J.
    Beriwal, Sushil
    BRACHYTHERAPY, 2013, 12 (03) : 248 - 253
  • [23] SALVAGE HIGH-DOSE-RATE INTERSTITIAL BRACHYTHERAPY IN RECURRRENT AND PREVIOUSLY IRRADIATED HEAD AND NECK CANCER.
    Gutierrez Bayard, L.
    Salas Buzon, M. C.
    Angulo Pain, M. E.
    Munive Alvarez, E.
    Gonzalez Calvo, E.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S270 - S270
  • [24] Experience of high-dose-rate brachytherapy for head and neck cancer treated by a customized intraoral mold technique
    Obinata K.
    Ohmori K.
    Shirato H.
    Nakamura M.
    Radiation Medicine, 2007, 25 (4): : 181 - 186
  • [25] Pilot study of intraoperative high dose rate brachytherapy for head and neck cancer
    Nag, S
    Schuller, D
    Pak, V
    Young, D
    Grecula, J
    Bauer, C
    Samsami, N
    RADIOTHERAPY AND ONCOLOGY, 1996, 41 (02) : 125 - 130
  • [26] In vivo dosimetry with alanine/electron spin resonance dosimetry to evaluate the urethra dose during high-dose-rate brachytherapy
    Wagner, Daniela
    Herrnann, Markus
    Hille, Andrea
    BRACHYTHERAPY, 2017, 16 (04) : 815 - 821
  • [27] In vivo dosimetry using MOSkin detector during Cobalt-60 high-dose-rate (HDR) brachytherapy of skin cancer
    Jamalludin, Z.
    Jong, W. L.
    Ho, G. F.
    Rosenfeld, A. B.
    Ung, N. M.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (04) : 1099 - 1107
  • [28] In vivo dosimetry using MOSkin detector during Cobalt-60 high-dose-rate (HDR) brachytherapy of skin cancer
    Z. Jamalludin
    W. L. Jong
    G. F. Ho
    A. B. Rosenfeld
    N. M. Ung
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 1099 - 1107
  • [29] A Verification of High-Dose-Rate Brachytherapy Dose Distributions for Prostate Cancer with a VIPET Polymer Gel Dosimeter
    Eguchi, K.
    Watanabe, Y.
    Mizukami, S.
    Maeyama, T.
    Hayashi, S.
    Gomi, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E238 - E238
  • [30] A phamtom study: In vivo rectal dosimetry of high dose rate brachytherapy in cervical cancer
    Moonkum, Nutthapong
    Turathong, Suriyaporn
    Pinitpatcharalert, Attapol
    Seechompoo, Janrudi
    Suetong, Chantiya
    Danthanavat, Nuttapong
    Tochaikul, Gunjanaporn
    APPLIED RADIATION AND ISOTOPES, 2023, 192