Stability and Performance of the Binary Compensation Unit for Cryogenic Current Comparator Bridges

被引:6
|
作者
Gotz, Martin [1 ]
Drung, Dietmar [2 ]
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
[2] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
Calibration; current comparator; electrical resistance measurement; measurement uncertainty; precision measurement;
D O I
10.1109/TIM.2017.2659998
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As a key module of the redesigned cryogenic current comparator setup, the binary compensation unit is now in everyday use for resistance calibration at Physikalisch-Technische Bundesanstalt (PTB), as well as in a number of national metrology institutes. In a first step, its excellent performance was demonstrated in consistency checks involving the quantum Hall resistance and normal resistors with nominal values 100 Omega and 12.9 k Omega. Meanwhile, the stability of this compensation unit could be evaluated, too. Our analysis is based on the results of calibrations at regular intervals of 20 weeks covering more than three years. Also the influence of temperature has been studied experimentally. From the data presented here, we conclude that the device under test can be considered to be stable within 1 part in 10(4) over ten years.
引用
收藏
页码:1467 / 1474
页数:8
相关论文
共 50 条
  • [41] Results from a detailed calculation of the sensitivity of a cryogenic current comparator
    Early, MD
    van Dam, MA
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 165 - 166
  • [42] SIMULATION OF A QUANTUM HALL CRYOGENIC CURRENT COMPARATOR RESISTANCE BRIDGE
    Lawson, T. B.
    Early, M. D.
    Jones, K.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 623 - 624
  • [43] Robust Control of a Two-Terminal Cryogenic Current Comparator
    Bierzychudek, M. E.
    Sanchez-Pena, R. S.
    Tonina, Alejandra
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (06) : 1736 - 1742
  • [44] INTEGRATED CRYOGENIC CURRENT COMPARATOR BASED ON SUPERCONDUCTOR LSI TECHNOLOGY
    Urano, C.
    Maruyama, M.
    Oe, T.
    Maezawa, M.
    Yamada, T.
    Hidaka, M.
    Satoh, T.
    Nagasawa, S.
    Hinode, K.
    Kiryu, S.
    Kaneko, N.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 763 - +
  • [45] Uncertainty evaluation in a two-terminal cryogenic current comparator
    Bierzychudek, M. E.
    Elmquist, R. E.
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 152 - +
  • [46] 1:30000 Cryogenic Current Comparator with optimum SQUID readout
    Bartolomé, E
    Sesé, J
    Rietveld, G
    Flokstra, J
    Rillo, C
    Camón, A
    Rogalla, H
    2002 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CONFERENCE DIGEST, 2002, : 280 - 281
  • [47] Results from a detailed calculation of the sensitivity of a cryogenic current comparator
    Early, MD
    van Dam, MA
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) : 379 - 382
  • [48] THE RATIO ERROR OF THE OVERLAPPED-TUBE CRYOGENIC CURRENT COMPARATOR
    SEPPA, H
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1990, 39 (05) : 689 - 697
  • [49] Resistance bridge based on the Cryogenic Current Comparator in a transport dewar
    Bartolomé, E
    Camón, A
    Sesé, J
    Rillo, C
    Flokstra, J
    Rietveld, G
    Rogalla, H
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 867 - 870
  • [50] A METHOD FOR COMPENSATION OF THERMAL DRIFT OF FERROMAGNETIC CURRENT COMPARATOR
    TANAKA, S
    SEKINE, K
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1969, IM18 (01) : 63 - &