Free-breathing high-pitch 80 kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose

被引:22
|
作者
Bodelle, Boris [1 ]
Fischbach, Constanze [1 ]
Booz, Christian [1 ]
Yel, Ibrahim [1 ]
Frellesen, Claudia [1 ]
Beeres, Martin [1 ]
Vogl, Thomas J. [1 ]
Scholtz, Jan-Erik [1 ]
机构
[1] Goethe Univ Frankfurt, Dept Diagnost & Intervent Radiol, Theodor Stern Kai 7, D-60590 Frankfurt, Germany
关键词
High pitch CT; Third generation dual-source CT; Free breathing; Pediatric CT; Chest CT; FILTERED BACK-PROJECTION; AFFIRMED ITERATIVE RECONSTRUCTION; ADVERSE EVENTS; CT; SEDATION; CHILDREN; CANCER; RISKS;
D O I
10.1016/j.ejrad.2017.01.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To investigate image quality, presence of motion artifacts and effects on radiation dose of 80 kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT). Materials and methods: The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1 +/- 4.9 years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n = 31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n = 56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated. Results: Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p > 0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (p < 0.01). Motion artifacts were reduced significantly (p = 0.001) with DSCT. DSCT with ADMIRE showed the highest overall IQ (p < 0.0001). Radiation dose was lower for DSCT compared to SSCT (median SSDE: 0.82 mGy vs. 0.92 mGy, p < 0.02; median ED: 0.4 mSv vs. 0.48 mSv, p = 0.02). Conclusions: High-pitch 80 kVp chest DSCT in combination with ADMIRE reduces motion artifacts and increases image quality while lowering radiation exposure in free-breathing pediatric patients without sedation. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:208 / 214
页数:7
相关论文
共 50 条
  • [41] Computed Tomography Angiography with a 192-slice Dual-source Computed Tomography System: Improvements in Image Quality and Radiation Dose
    Linsen, Philip V. M.
    Coenen, Adriaan
    Lubbers, Marisa M.
    Dijkshoorn, Marcel L.
    Ouhlous, Mohamed
    Nieman, Koen
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2016, 6
  • [42] Pediatric chest computed tomography at 100 kVp with tin filtration: comparison of image quality with 70-kVp imaging at comparable radiation dose
    Vivier, Sophie
    Deken, Valerie
    Arous, Younes
    Faivre, Jean-Baptiste
    Duhamel, Alain
    Deschildre, Antoine
    Flohr, Thomas
    Remy, Jacques
    Remy-Jardin, Martine
    PEDIATRIC RADIOLOGY, 2020, 50 (02) : 188 - 198
  • [43] Dual-source computed tomography in patients with acute chest pain: feasibility and image quality
    Thomas Schertler
    Hans Scheffel
    Thomas Frauenfelder
    Lotus Desbiolles
    Sebastian Leschka
    Paul Stolzmann
    Burkhardt Seifert
    Thomas G. Flohr
    Borut Marincek
    Hatem Alkadhi
    European Radiology, 2007, 17 : 3179 - 3188
  • [44] Dual-source computed tomography in patients with acute chest pain: feasibility and image quality
    Schertler, Thomas
    Scheffel, Hans
    Frauenfelder, Thomas
    Desbiolles, Lotus
    Leschka, Sebastian
    Stolzmann, Paul
    Seifert, Burkhardt
    Flohr, Thomas G.
    Marincek, Borut
    Alkadhi, Hatem
    EUROPEAN RADIOLOGY, 2007, 17 (12) : 3179 - 3188
  • [45] Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
    Zhuang, Y.
    Huang, W.
    Shi, Y.
    Bo, G.
    Lu, D.
    Zhang, J.
    Kong, D.
    Shit, Y.
    Wang, B.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (02): : 225 - 233
  • [46] Feasibility of Respiratory-gated High-pitch Spiral CT: Free-breathing Inspiratory Image Quality
    Lell, Michael M.
    Scharf, Michael
    Eller, Achim
    Wuest, Wolfgang
    Allmendinger, Thomas
    Fuchs, Florian
    Achenbach, Stephan
    Uder, Michael
    May, Matthias S.
    ACADEMIC RADIOLOGY, 2016, 23 (04) : 406 - 412
  • [47] High-Pitch Spiral Coronary Angiography by 128-Slice Dual-Source Computed Tomography (CT) Realizes a Sensational Low Radiation Exposure Without Reduced Image Quality
    Utanohara, Yuko
    Iguchi, Nobuo
    Yamashita, Mitsumi
    Umemura, Jun
    Sumiyoshi, Tetsuya
    CIRCULATION, 2010, 122 (21)
  • [48] Image Quality and Radiation Dose of High-Pitch Dual-Source Spiral Cardiothoracic Computed Tomography in Young Children with Congenital Heart Disease: Comparison of Non-Electrocardiography Synchronization and Prospective Electrocardiography Triggering
    Goo, Hyun Woo
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (06) : 1031 - 1041
  • [49] Dose and image quality of high-pitch dual source computed tomography for the evaluation of cervical lymph node status - Comparison to regular 128-slice single source computed tomography
    Bodelle, Boris
    Bauer, Ralf W.
    Holthaus, Lara
    Schulz, Boris
    Al-Butmeh, Firas
    Wichmann, Julian L.
    Beeres, Martin
    Vogl, Thomas J.
    Kerl, J. Matthias
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (06) : E281 - E285
  • [50] Feasibility and Radiation Dose of High-Pitch Acquisition Protocols in Patients Undergoing Dual-Source Cardiac CT
    Sommer, Wieland H.
    Albrecht, Edda
    Bamberg, Fabian
    Schenzle, Jan C.
    Johnson, Thorsten R.
    Neumaier, Klement
    Reiser, Maximilian F.
    Nikolaou, Konstatin
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : 1306 - 1312