THA With Delta Ceramic on Ceramic Results of a Multicenter Investigational Device Exemption Trial

被引:129
|
作者
Hamilton, William G. [1 ]
McAuley, James P. [2 ]
Dennis, Douglas A. [3 ,4 ,5 ]
Murphy, Jeffrey A. [6 ]
Blumenfeld, Thomas J. [7 ]
Politi, Joel [8 ]
机构
[1] Anderson Orthopaed Res Inst, Alexandria, VA 22306 USA
[2] Univ Western Ontario, Dept Orthopaed Surg, London Hlth Sci Ctr, London, ON, Canada
[3] Univ Tennessee, Dept Biomed Engn, Knoxville, TN USA
[4] Univ Colorado, Hlth Sci Ctr, Denver, CO USA
[5] Rocky Mt Musculoskeletal Res Lab, Denver, CO USA
[6] DePuy Orthopaed, Warsaw, IN USA
[7] Univ Calif Davis, Sutter Gen Hosp, Sacramento, CA 95817 USA
[8] Cardinal Orthopaed Inst, Columbus, OH USA
关键词
TOTAL HIP-ARTHROPLASTY; POLYETHYLENE ACETABULAR LINER; FEMORAL-HEAD; SQUEAKING HIP; COMPONENT; BEARINGS; FRACTURE; WEAR; FAILURE; REPLACEMENT;
D O I
10.1007/s11999-009-1091-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although the published studies on the outcomes of total hip arthroplasty (THA) performed with currently available ceramic components show high survivorship and low bearing wear at midterm followup, concern over ceramic fracture and squeaking persist. For these reasons, the use of ceramic is limited. Recently, a new alumina matrix composite material (Delta ceramic) with improved material properties was developed to address these concerns. We report the early outcomes and complications of a prospective, randomized, multicenter trial of 263 patients (264 hips) at eight centers, comparing a Delta ceramic-on-ceramic (COC) articulation with a Delta ceramic head-crosslinked polyethylene bearing combination (COP). There were 177 COC hips and 87 COP hips. Complications were reported for all patients, whereas clinical and radiographic results were provided for the 233 patients with minimum 2-year followup (average, 31.2 months; range, 21-49 months). The Harris hip scores and clinical, radiographic, and survivorship outcomes were similar in both groups. There were four (2%) revisions in the COC group and two (2%) in the COP group. We encountered three intraoperative ceramic liner-related events. In addition, one patient receiving the COC underwent revision for chipping of the ceramic liner, and a second had ceramic fragmentation on followup radiographs but has not undergone revision. These liner related complications remain a concern. No patient reported squeaking in either group; this leaves us hopeful the new material will lessen the frequency of squeaking. In the short term, the Delta COC articulation provided similar functional scores and survivorship and complication rates with the ceramic head mated with crosslinked polyethylene.
引用
收藏
页码:358 / 366
页数:9
相关论文
共 50 条
  • [41] Clinical Outcomes With Selectively Constrained SECURE-C Cervical Disc Arthroplasty Two-Year Results From a Prospectivei, Randomized, Controlled, Multicenter Investigational Device Exemption Study
    Vaccaro, Alexander
    Beutler, William
    Peppelman, Walter
    Marzluff, Joseph M.
    Highsmith, Jason
    Mugglin, Andrew
    DeMuth, George
    Gudipally, Manasa
    Baker, Kelly J.
    SPINE, 2013, 38 (26) : 2227 - 2239
  • [42] What Is the Frequency of Fracture of Ceramic Components in THA? Results from the Norwegian Arthroplasty Register from 1997 to 2017
    Hallan, Geir
    Fenstad, Anne Marie
    Furnes, Ove
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2020, 478 (06) : 1254 - 1261
  • [43] Ceramic Crowns and Sleep Bruxism: First Results from a Randomized Trial
    Schmitter, Marc
    Boemicke, Wolfgang
    Behnisch, Rouven
    Bermejo, Justo Lorenzo
    Waldecker, Moritz
    Rammelsberg, Peter
    Ohlmann, Brigitte
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (01)
  • [44] Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol
    Heatley, Gerald
    Sood, Poornima
    Goldstein, Daniel
    Uriel, Nir
    Cleveland, Joseph
    Middlebrook, Don
    Mehra, Mandeep R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : 528 - 536
  • [45] Long-term outcomes of the Ovation Stent Graft System investigational device exemption trial for endovascular abdominal aortic aneurysm repair
    Barleben, Andrew
    Mathlouthi, Asma
    Mehta, Manish
    Nolte, Thomas
    Valdes, Francisco
    Malas, Mahmoud B.
    JOURNAL OF VASCULAR SURGERY, 2020, 72 (05) : 1667 - +
  • [46] Early report from an investigator-initiated investigational device exemption clinical trial on physician-modified endovascular grafts DISCUSSION
    Cheng, Stephen
    Starnes, Benjamin Ware
    JOURNAL OF VASCULAR SURGERY, 2013, 58 (02) : 317 - 317
  • [47] Long-Term Outcomes of the Ovation Stent Graft System Investigational Device Exemption Trial for Endovascular Abdominal Aortic Aneurysm Repair
    Barleben, Andrew
    Mathlouthi, Asma
    Mehta, Manish
    Nolte, Thomas
    Valdes, Francisco
    Malas, Mahmoud B.
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (03) : E92 - E92
  • [48] Branched stented anastomosis frozen elephant trunk repair: Early results from a physician-sponsored investigational device exemption study
    Roselli, Eric E.
    Vargo, Patrick R.
    Bakaeen, Faisal
    Koprivanac, Marijan
    Burns, Daniel
    Kuramochi, Yuki
    Gillinov, Marc
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2024, 168 (03): : 746 - 756
  • [49] Human Fibroblast-Derived Dermal Substitute: Results from a Treatment Investigational Device Exemption (TIDE) Study in Diabetic Foot Ulcers
    Warriner, Robert A., III
    Cardinal, Matthew
    ADVANCES IN SKIN & WOUND CARE, 2011, 24 (07) : 306 - 311
  • [50] Ten to 13-Year Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty in Patients Less Than 30 Years Old
    Park, Jung-Wee
    Ko, Young-Seung
    Lee, Young-Kyun
    Ha, Yong-Chan
    Koo, Kyung-Hoi
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2023, 105 (10): : 789 - 796