THA With Delta Ceramic on Ceramic Results of a Multicenter Investigational Device Exemption Trial

被引:129
|
作者
Hamilton, William G. [1 ]
McAuley, James P. [2 ]
Dennis, Douglas A. [3 ,4 ,5 ]
Murphy, Jeffrey A. [6 ]
Blumenfeld, Thomas J. [7 ]
Politi, Joel [8 ]
机构
[1] Anderson Orthopaed Res Inst, Alexandria, VA 22306 USA
[2] Univ Western Ontario, Dept Orthopaed Surg, London Hlth Sci Ctr, London, ON, Canada
[3] Univ Tennessee, Dept Biomed Engn, Knoxville, TN USA
[4] Univ Colorado, Hlth Sci Ctr, Denver, CO USA
[5] Rocky Mt Musculoskeletal Res Lab, Denver, CO USA
[6] DePuy Orthopaed, Warsaw, IN USA
[7] Univ Calif Davis, Sutter Gen Hosp, Sacramento, CA 95817 USA
[8] Cardinal Orthopaed Inst, Columbus, OH USA
关键词
TOTAL HIP-ARTHROPLASTY; POLYETHYLENE ACETABULAR LINER; FEMORAL-HEAD; SQUEAKING HIP; COMPONENT; BEARINGS; FRACTURE; WEAR; FAILURE; REPLACEMENT;
D O I
10.1007/s11999-009-1091-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although the published studies on the outcomes of total hip arthroplasty (THA) performed with currently available ceramic components show high survivorship and low bearing wear at midterm followup, concern over ceramic fracture and squeaking persist. For these reasons, the use of ceramic is limited. Recently, a new alumina matrix composite material (Delta ceramic) with improved material properties was developed to address these concerns. We report the early outcomes and complications of a prospective, randomized, multicenter trial of 263 patients (264 hips) at eight centers, comparing a Delta ceramic-on-ceramic (COC) articulation with a Delta ceramic head-crosslinked polyethylene bearing combination (COP). There were 177 COC hips and 87 COP hips. Complications were reported for all patients, whereas clinical and radiographic results were provided for the 233 patients with minimum 2-year followup (average, 31.2 months; range, 21-49 months). The Harris hip scores and clinical, radiographic, and survivorship outcomes were similar in both groups. There were four (2%) revisions in the COC group and two (2%) in the COP group. We encountered three intraoperative ceramic liner-related events. In addition, one patient receiving the COC underwent revision for chipping of the ceramic liner, and a second had ceramic fragmentation on followup radiographs but has not undergone revision. These liner related complications remain a concern. No patient reported squeaking in either group; this leaves us hopeful the new material will lessen the frequency of squeaking. In the short term, the Delta COC articulation provided similar functional scores and survivorship and complication rates with the ceramic head mated with crosslinked polyethylene.
引用
收藏
页码:358 / 366
页数:9
相关论文
共 50 条
  • [21] Vertebral Body Tethering in Skeletally Immature Patients: Results of a Prospective US FDA Investigational Device Exemption Study
    Larson, A. Noelle
    Todderud, Julia E.
    Mathew, Smitha E.
    Nassr, Ahmad
    Sebastian, Arjun S.
    Potter, D. Dean
    Milbrandt, Todd A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2025, 107 (03): : 249 - 256
  • [22] Atrial septal defect occlusion with the Das Angel Wings™ device:: Phase II investigational device exemption (IDE) protocol interim results
    O'Laughlin, MP
    Mendelsohn, AM
    Sommer, RJ
    Vincent, JA
    Morrow, R
    Cheatham, JP
    Harrison, JK
    Weber, HS
    Das, GS
    CIRCULATION, 1998, 98 (17) : 754 - 754
  • [23] Randomized Clinical Trial of Implant-Supported Ceramic-Ceramic and Metal-Ceramic Fixed Dental Prostheses: Preliminary Results
    Esquivel-Upshaw, Josephine F.
    Clark, Arthur E.
    Shuster, Jonathan J.
    Anusavice, Kenneth J.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (02): : 73 - 82
  • [24] Ceramic-on-Ceramic versus Ceramic-on-Polyethylene Bearings in Total Hip Arthroplasty: Results of a Multicenter Prospective Randomized Study and Update of Modern Ceramic Total Hip Trials in the USA
    Bal, B. S.
    Aleto, T. J.
    Garino, J. P.
    Toni, A.
    Hendricks, K. J.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2005, : 101 - 108
  • [25] Complications of lumbar artificial disc replacement versus fusion: Results from the randomized, multicenter Food and Drug Administration investigational device exemption study of the CHARITE Artificial Disc
    Geisler, FH
    Holt, RT
    Majd, ME
    Isaza, J
    Blumenthal, SL
    McAfee, PC
    Guyer, RD
    Hochschuler, SH
    Garcia, R
    Regan, JJ
    NEUROSURGERY, 2005, 57 (02) : 397 - 397
  • [26] Midterm Results of Large Diameter Biolox Forte Ceramic Head on Delta Ceramic Liner Articulation in Total Hip Arthroplasty
    Kang, Bun-Jung
    Ha, Yong-Chan
    Hwang, Sun-Chul
    Lee, Young-Kyun
    Koo, Kyung-Hoi
    JOURNAL OF ARTHROPLASTY, 2014, 29 (12): : 2412 - 2414
  • [27] Lessons Learned from the Investigational Device Exemption Review of Children's Oncology Group Trial AAML1031
    Meshinchi, Soheil
    Hunger, Stephen P.
    Aplenc, Richard
    Adamson, Peter C.
    Jessup, J. Milburn
    CLINICAL CANCER RESEARCH, 2012, 18 (06) : 1547 - 1554
  • [28] Long-Term Outcomes After Melody Transcatheter Pulmonary Valve Replacement in the US Investigational Device Exemption Trial
    Jones, Thomas K.
    McElhinney, Doff B.
    Vincent, Julie A.
    Hellenbrand, William E.
    Cheatham, John P.
    Berman, Darren P.
    Zahn, Evan M.
    Khan, Danyal M.
    Rhodes, John F., Jr.
    Weng, Shicheng
    Bergersen, Lisa J.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (01) : 22 - 32
  • [29] Fourth-generation ceramic-on-ceramic THA results in improvements in midterm outcomes compared to third-generation THA but does not resolve noise problems: a cohort study of a single-hip system
    Kim, Seung-Chan
    Lim, Young-Wook
    Jo, Woo-Lam
    Park, Hyun-Woo
    Han, Sung-Bin
    Kwon, Soon-Yong
    Kim, Yong-Sik
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [30] Ceramic-on-ceramic versus ceramic-on-polyethylene bearings in total hip arthroplasty: Results of a multicenter prospective randomized study and update of modern ceramic total hip trials in the United States
    Bal, BS
    Aleto, TJ
    Garino, JP
    Toni, A
    Hendricks, KJ
    HIP INTERNATIONAL, 2005, 15 (03) : 129 - 135