The ground surface energy balance in modelling horizontal ground heat exchangers

被引:1
|
作者
Bortoloni, Marco [1 ]
Bottarelli, Michele [1 ]
Su, Yuehong [2 ]
机构
[1] Univ Ferrara, Dipartimento Architettura, I-44121 Ferrara, Italy
[2] Univ Nottingham, Dept Architecture & Built Environm, Nottingham NG7 2RD, England
来源
关键词
SIMULATION; TEMPERATURE; LAYER; SOIL;
D O I
10.1088/1742-6596/796/1/012024
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of horizontal ground heat exchangers (HGHEs) is strongly dependent on climatic conditions, due to the low installation depth. In numerical modelling of HGHEs, the estimation of shallow soil temperature distribution is a key issue, therefore the boundary condition (BC) at the ground surface should be assigned carefully. With this in mind, a model of the energy balance at the ground surface (GSEB), based on weather variables, was developed. The model was tested as the r1kind BC at ground surface in modelling HGHEs by means of the FEM code Comsol Multiphysics, solving the unsteady heat transfer problem in a 2D domain The GSEB model was calibrated and validated with the observed soil temperature at different depths. In addition, the effect on numerical solutions of different BCs, when assigned at the ground surface, was analysed. Three different simulations were carried out applying the GSEB model, the equivalent surface heat flux and temperature as boundary conditions of the 1st, 2nd and 3rd kind, respectively. The results of this study indicate that the use of the GSEB model is a preferable approach to the problem and that the use of the equivalent surface temperature can be considered as a reasonable simplification.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Sensitivity analysis of the ground-coupled heat pump system with horizontal ground heat exchangers in the cold regions of China
    Cang Tong
    Xiangli Li
    Lin Duanmu
    Building Simulation, 2019, 12 : 573 - 584
  • [32] Sensitivity analysis of the ground-coupled heat pump system with horizontal ground heat exchangers in the cold regions of China
    Tong, Cang
    Li, Xiangli
    Lin Duanmu
    BUILDING SIMULATION, 2019, 12 (04) : 573 - 584
  • [33] A numerical study on utilizing horizontal flat-panel ground heat exchangers in ground-coupled heat pumps
    Habibi, Mohammad
    Amadeh, Ali
    Hakkaki-Fard, Ali
    RENEWABLE ENERGY, 2020, 147 : 996 - 1010
  • [34] ANALYSIS OF GROUND HEAT EXCHANGERS
    Kosicanova, Danica
    GEOCONFERENCE ON ENERGY AND CLEAN TECHNOLOGIES, 2013, : 19 - 26
  • [35] GROUND SOURCE HEAT PUMP WITH HORIZONTAL GROUND BURIED PIPES: MODELLING AND OPTIMIZATION WITH TRNSYS
    Hou, Gaoyang
    Taherian, Hessam
    2018 BUILDING PERFORMANCE ANALYSIS CONFERENCE AND SIMBUILD, 2018, : 607 - 614
  • [36] NUMREICAL ANALYSIS OF SYSTEMS WITH VAPOUR COMPRESSOR HEAT PUMPS AND HORIZONTAL GROUND HEAT EXCHANGERS
    Hanuszkiewicz-Drapala, Malgorzata
    RYNEK ENERGII, 2010, (05): : 82 - 88
  • [37] Investigating the Thermal Performance of Horizontal Slinky Ground Heat Exchangers for Geothermal Heat Pump
    Cui, Ping
    Yang, Jie
    Lin, Yun
    Fang, Zhaohong
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 73 - 83
  • [38] Ground thermal response to borehole ground heat exchangers
    Mikhaylova, O.
    Johnston, I. W.
    Narsilio, G. A.
    ENERGY GEOTECHNICS, 2016, : 179 - 186
  • [39] Artificial neural networks for predicting the performance of heat pumps with horizontal ground heat exchangers
    Zhou, Yu
    Narsilio, Guillermo
    Makasis, Nikolas
    Soga, Kenichi
    Chen, Peng
    Aye, Lu
    FRONTIERS IN ENERGY RESEARCH, 2024, 12
  • [40] Methodology for estimating the ground heat absorption rate of Ground Heat Exchangers
    Stylianou, Iosifina Iosif
    Florides, Georgios
    Tassou, Savvas
    Tsiolakis, Efthymios
    Christodoulides, Paul
    ENERGY, 2017, 127 : 258 - 270