Investigating the Thermal Performance of Horizontal Slinky Ground Heat Exchangers for Geothermal Heat Pump

被引:2
|
作者
Cui, Ping [1 ,2 ,3 ]
Yang, Jie [3 ]
Lin, Yun [3 ]
Fang, Zhaohong [3 ]
机构
[1] Minist Educ, Key Lab Renewable Energy Utilizat Technol Bldg, Jinan, Peoples R China
[2] Shandong Jianzhu Univ, Shandong Key Lab Bldg Energy Saving Tech, Jinan, Peoples R China
[3] Shandong Jianzhu Univ, Sch Thermal Energy Engn, Jinan, Peoples R China
关键词
Ground-coupled heat pump; Slinky-coil horizontal ground heat exchanger; Heat transfer model;
D O I
10.1007/978-3-642-39581-9_8
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The horizontal ground heat exchanger (HGHE) with slinky-coiled pipes recently has been used as a heat source/sink for geothermal heat pump systems because of the significant lower initial cost. A simplified heat transfer model suitable for engineering design of the slinky HGHEs is developed. The model is based on the one-dimensional transient heat transfer in an infinite medium, considering the influence of the tube length per area and the different effects of longterm mean load and short-term intermittent load. A case study is carried out to design the HGHE size by using the proposed model. Some key factors which influence the performance of the HGHE are also discussed such as the thermal properties of the ground and the pipe length per area.
引用
收藏
页码:73 / 83
页数:11
相关论文
共 50 条
  • [1] Simulation of thermal performance of horizontal slinky-loop heat exchangers for ground source heat pumps
    Chong, Chiew Shan Anthony
    Gan, Guohui
    Verhoef, Anne
    Garcia, Raquel Gonzalez
    Vidale, Pier Luigi
    [J]. APPLIED ENERGY, 2013, 104 : 603 - 610
  • [2] Comparing the thermal performance of horizontal slinky-loop and vertical slinky-loop heat exchangers
    Chong, C. S. A.
    Gan, G.
    Verhoef, A.
    Garcia, R. G.
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2014, 9 (04) : 250 - 255
  • [3] Numerical investigation into the thermal interference of slinky ground heat exchangers
    Luo, Man
    Gan, Guohui
    [J]. APPLIED THERMAL ENGINEERING, 2024, 248
  • [4] Numerical modeling of slinky-coil horizontal ground heat exchangers
    Fujii, Hikari
    Nishi, Keita
    Komaniwa, Yoshihito
    Chou, Naokatsu
    [J]. GEOTHERMICS, 2012, 41 : 55 - 62
  • [5] Case Study of a Heat Pump Installation with Horizontal Ground Heat Exchangers
    Marius, Mantulescu
    Stan, Fota
    Ioan, Tuns
    [J]. PROCEEDINGS OF THE 5TH WSEAS INTERNATIONAL CONFERENCE ON APPLIED AND THEORETICAL MECHANICS (MECHANICS '09), 2009, : 128 - 133
  • [6] Study Case of a Heat Pump Installation with Horizontal Ground Heat Exchangers
    Marius, Mantulescu
    Stan, Fota
    Ioan, Tuns
    [J]. PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ENVIRONMENTAL AND GEOLOGICAL SCIENCE AND ENGINEERING, 2009, : 278 - 283
  • [7] An analytical approach to evaluating the effect of thermal interaction of geothermal heat exchangers on ground heat pump efficiency
    Koohi-Fayegh, S.
    Rosen, M. A.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 78 : 184 - 192
  • [8] Computer simulation of borehole ground heat exchangers for geothermal heat pump systems
    Lee, C. K.
    Lam, H. N.
    [J]. RENEWABLE ENERGY, 2008, 33 (06) : 1286 - 1296
  • [9] Efficiency of vertical geothermal heat exchangers in the ground source heat pump system
    Heyi Zeng
    Nairen Diao
    Zhaohong Fang
    [J]. Journal of Thermal Science, 2003, 12 : 77 - 81
  • [10] Efficiency of Vertical Geothermal Heat Exchangers in the Ground Source Heat Pump System
    Zeng, Heyi
    Diao, Nairen
    Fang, Zhaohong
    [J]. JOURNAL OF THERMAL SCIENCE, 2003, 12 (01) : 77 - 81