Hamamatsu S8550 APD arrays for high-resolution scintillator matrices readout

被引:31
|
作者
Kapusta, M [1 ]
Crespo, P
Wolski, D
Moszynski, M
Enghardt, W
机构
[1] Soltan Inst Nucl Studies, PL-05400 Otwock, Poland
[2] FZ Rossendorf, D-01314 Dresden, Germany
关键词
avalanche photodiode array;
D O I
10.1016/S0168-9002(03)00809-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The performance of Hamamatsu S8550 avalanche photodiode (APD) arrays for scintillator matrices readout has been evaluated. The S8550 device is a monolithic 8 x 4 pixels structure with an active area of 2.56 mm(2) for each pixel. The device allows stable operation at gains up to 74, with a detection efficiency of about 60% for photons of 420 nm wavelength. It is characterized by a low noise equal to 27 electrons equivalent noise charge at room temperature. The energy resolution of 14.6%, for the 511 keV peak from a Na-22 source has been recorded with a 2 x 2 x 10 mm(3) LSO crystal coupled to one pixel. The number of electron-hole pairs produced by the 511 keV photopeak absorbed in LSO is equal to 4830+/-240 e-h/MeV. Coupling LSO scintillator crystals to individual pixels of the APD array a coincidence timing resolution of 3.0+/-0.2 ns FWHM has been measured for the 511 keV gamma-rays from a Na-22 source. Finally, we compared the characteristics and readout performance of the Hamamatsu array with the results measured earlier under the same conditions for the quadrant large area avalanche photodiodes of Advanced Photonics Inc. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:139 / 142
页数:4
相关论文
共 50 条
  • [21] Development of large-area, reverse-type APD-arrays for high-resolution medical imaging
    Kataoka, J.
    Koizumi, M.
    Tanaka, S.
    Ishibashi, H.
    Nakamori, T.
    Kawai, N.
    Ikeda, H.
    Ishikawa, Y.
    Kawabata, N.
    Matsunaga, Y.
    Kishimoto, S.
    Kubo, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 323 - 326
  • [22] Optical fiber readout of scintillator arrays using a multi-channel PMT: a high resolution PET detector for animal imaging
    UCLA Sch of Medicine, Los Angeles, United States
    IEEE Trans Nucl Sci, 3 pt 2 (1932-1937):
  • [23] Optical fiber readout of scintillator arrays using a multi-channel PMT: A high resolution PET detector for animal imaging
    Cherry, SR
    Shao, YP
    Siegel, S
    Silverman, RW
    Mumcuoglu, E
    Meadors, K
    Phelps, ME
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1932 - 1937
  • [24] Design studies of a high resolution PET detector using APD arrays
    Shao, Y
    Silverman, RW
    Farrell, R
    Cirignano, L
    Grazioso, R
    Shah, KS
    Visser, G
    Clajus, M
    Tümer, TO
    Cherry, SR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1051 - 1057
  • [26] HIGH-RESOLUTION BEAMFORMING WITH OVERSAMPLED ARRAYS
    BYRNE, CL
    FITZGERALD, RM
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1983, 74 (04): : 1224 - 1227
  • [27] Fabrication of high-resolution micropolarizer arrays
    Guo, JP
    Brady, DJ
    OPTICAL ENGINEERING, 1997, 36 (08) : 2268 - 2271
  • [28] High-resolution beamforming with oversampled arrays
    Byrne, C.L.
    Fitzgerald, R.M.
    1600, (74):
  • [29] A HIGH-RESOLUTION INDUCTION STRIP READOUT FOR WIRE CHAMBERS
    KRUSE, A
    REICHEL, T
    ZECH, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (03): : 485 - 490
  • [30] Signal to noise ratio of APD-based monolithic scintillator detectors for high resolution PET
    Maas, Marnix C.
    Schaart, Dennis R.
    van der Laan, D. J.
    van Dam, Herman T.
    Huizenga, Jan
    Brouwer, J. C.
    Bruyndonckx, Peter
    Lemaitre, Cedric
    van Eijk, Carel W. E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 842 - 852