Anchored Transosseous-Equivalent Versus Anchorless Transosseous Rotator Cuff Repair

被引:20
|
作者
Kilcoyne, Kelly G. [1 ]
Guillaume, Stanley G. [2 ]
Hannan, Catherine V. [2 ]
Langdale, Evan R. [2 ]
Belkoff, Stephen M. [2 ]
Srikumaran, Uma [2 ]
机构
[1] William Beaumont Army Med Ctr, El Paso, TX 79920 USA
[2] Johns Hopkins Univ, Dept Orthopaed Surg, 601 North Caroline St, Baltimore, MD 21287 USA
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2017年 / 45卷 / 10期
关键词
arthroscopic bone tunnels; biomechanical testing; rotator cuff repair; transosseous equivalent; SUTURE-BRIDGE TECHNIQUE; FULL-THICKNESS TEARS; DOUBLE-ROW FIXATION; SINGLE-ROW; ARTHROSCOPIC REPAIR; RETEAR PATTERNS; BIOMECHANICAL EVALUATION; CLINICAL-OUTCOMES; NO DIFFERENCE; SUPRASPINATUS;
D O I
10.1177/0363546517706136
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The original approach for the repair of torn rotator cuffs involved an open technique with sutures passing through the greater tuberosity and tendon. The development of suture anchors allowed for an all-arthroscopic approach with anchor configurations attempting to re-create a transosseous fixation pattern. Presently, an arthroscopic approach can be combined with a transosseous suture configuration without using anchors. Purpose: To evaluate cyclic loading, ultimate load to failure, and the failure mechanisms of transosseous-equivalent (TOE) repair with anchors and anchorless transosseous (AT) repair of rotator cuff tears. Study Design: Controlled laboratory study. Methods: Supraspinatus tears (25 mm) were created in 20 fresh-frozen, human cadaveric shoulders, which were randomized to TOE or AT repair (10 in each group, paired experimental design). Biomechanical testing was performed with an initial preload, cyclic loading, and load to failure. Optical markers were used to monitor gap formation in 3 planes, and the failure mode was recorded. Paired t tests were used to make comparisons of biomechanical parameters between the groups. Multinomial logistic regression was used to compare failure modes between the groups. Significance was set to .05. Results: The TOE group had a significantly higher mean (+/- SD) ultimate failure load (578.5 +/- 123.8 N) than the AT group (468.7 +/- 150.9 N) (P = .034). The TOE group also had a significantly less mean first-cycle excursion (2.97 +/- 1.97 mm) than the AT group (4.70 +/- 2.04 mm) (P = .046). There were no significant differences between the groups in cyclic elongation or linear stiffness during cyclic loading. Primary modes of failure were a type 2 tendon tear with medial tendon disruption in the TOE group (7/10) and a type 1 tendon tear with lateral tendon disruption in the AT group (6/10). Conclusion: TOE repair resulted in a significantly higher mean failure load compared with AT repair in a cadaveric model. The most common modes of failure were a type 2 tendon tear in the TOE group and a type 1 tendon tear in the AT group. Clinical Relevance: A higher mean failure load in TOE versus AT constructs may come at the cost of a less favorable failure mode adjacent to medial anchors at the musculotendinous junction, potentially making revision difficult.
引用
收藏
页码:2364 / 2371
页数:8
相关论文
共 50 条
  • [31] Shoulder abduction diminishes self-reinforcement in transosseous-equivalent rotator cuff repair in both knotted and knotless techniques
    Geoffrey C. S. Smith
    Patrick H. Lam
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 3818 - 3825
  • [32] True Transosseous Hybrid Rotator Cuff Repair
    Sanders, Brett
    ARTHROSCOPY TECHNIQUES, 2019, 8 (09): : E1013 - E1018
  • [33] Minimum 10-Year Outcomes of Primary Arthroscopic Transosseous-Equivalent Double-Row Rotator Cuff Repair
    Johannsen, Adam M.
    Arner, Justin W.
    Elrick, Bryant P.
    Nolte, Philip-C.
    Rakowski, Dylan R.
    Horan, Marilee P.
    Millett, Peter J.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2021, 49 (08): : 2035 - 2041
  • [34] Transosseous-Equivalent Repair for Distal Patellar Tendon Avulsion
    Galos, David K.
    Konda, Sanjit R.
    Kaplan, Daniel J.
    Ryan, William E.
    Alaia, Michael J.
    ARTHROSCOPY TECHNIQUES, 2016, 5 (02): : E385 - E389
  • [35] Part I: Footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique
    Park, Maxwell C.
    ElAttrache, Neal S.
    Tibone, James E.
    Ahmad, Christopher S.
    Jun, Bong-Jae
    Lee, Thay Q.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (04) : 461 - 468
  • [36] Evaluating transosseous anchorless repair for arthroscopic rotator cuff surgery: a comparative study with double row anchor repair
    Sundar, Shyam
    Sane, Rohit Mahesh
    Sundaramoorthy, Raghulraj
    Ashraf, Munis
    Rajan, David, V
    CLINICS IN SHOULDER AND ELBOW, 2025, 28 (01): : 23 - 30
  • [37] Does transosseous-equivalent rotator cuff repair biomechanically provide a "self-reinforcement'' effect compared with single-row repair?
    Park, Maxwell C.
    McGarry, Michelle H.
    Gunzenhauser, Robert C.
    Benefiel, Michael K.
    Park, Chong J.
    Lee, Thay Q.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (12) : 1813 - 1821
  • [38] Clinical and radiologic outcome of arthroscopic rotator cuff repair: single-row versus transosseous equivalent repair
    Jeong, Jeung Yeol
    Park, Keun Min
    Sundar, Shyam
    Yoo, Jae Chul
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (06) : 1021 - 1029
  • [39] Technique for a Novel Arthroscopic Transosseous Rotator Cuff Repair
    Castagna, Alessandro
    Gumina, Stefano
    Garofalo, Raffaele
    Mantovani, Matteo
    Kany, Jean
    Chillemi, Claudio
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2019, 20 (01): : 12 - 18
  • [40] Minimum Five-year Outcomes and Clinical Survivorship for Arthroscopic Transosseous-equivalent Double-row Rotator Cuff Repair
    Pogorzelski, Jonas
    Fritz, Erik M.
    Horan, Marilee P.
    Katthagen, J. Christoph
    Hussain, Zaamin B.
    Godin, Jonathan A.
    Millett, Peter J.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2019, 27 (24) : E1093 - E1101