Anchored Transosseous-Equivalent Versus Anchorless Transosseous Rotator Cuff Repair

被引:20
|
作者
Kilcoyne, Kelly G. [1 ]
Guillaume, Stanley G. [2 ]
Hannan, Catherine V. [2 ]
Langdale, Evan R. [2 ]
Belkoff, Stephen M. [2 ]
Srikumaran, Uma [2 ]
机构
[1] William Beaumont Army Med Ctr, El Paso, TX 79920 USA
[2] Johns Hopkins Univ, Dept Orthopaed Surg, 601 North Caroline St, Baltimore, MD 21287 USA
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2017年 / 45卷 / 10期
关键词
arthroscopic bone tunnels; biomechanical testing; rotator cuff repair; transosseous equivalent; SUTURE-BRIDGE TECHNIQUE; FULL-THICKNESS TEARS; DOUBLE-ROW FIXATION; SINGLE-ROW; ARTHROSCOPIC REPAIR; RETEAR PATTERNS; BIOMECHANICAL EVALUATION; CLINICAL-OUTCOMES; NO DIFFERENCE; SUPRASPINATUS;
D O I
10.1177/0363546517706136
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The original approach for the repair of torn rotator cuffs involved an open technique with sutures passing through the greater tuberosity and tendon. The development of suture anchors allowed for an all-arthroscopic approach with anchor configurations attempting to re-create a transosseous fixation pattern. Presently, an arthroscopic approach can be combined with a transosseous suture configuration without using anchors. Purpose: To evaluate cyclic loading, ultimate load to failure, and the failure mechanisms of transosseous-equivalent (TOE) repair with anchors and anchorless transosseous (AT) repair of rotator cuff tears. Study Design: Controlled laboratory study. Methods: Supraspinatus tears (25 mm) were created in 20 fresh-frozen, human cadaveric shoulders, which were randomized to TOE or AT repair (10 in each group, paired experimental design). Biomechanical testing was performed with an initial preload, cyclic loading, and load to failure. Optical markers were used to monitor gap formation in 3 planes, and the failure mode was recorded. Paired t tests were used to make comparisons of biomechanical parameters between the groups. Multinomial logistic regression was used to compare failure modes between the groups. Significance was set to .05. Results: The TOE group had a significantly higher mean (+/- SD) ultimate failure load (578.5 +/- 123.8 N) than the AT group (468.7 +/- 150.9 N) (P = .034). The TOE group also had a significantly less mean first-cycle excursion (2.97 +/- 1.97 mm) than the AT group (4.70 +/- 2.04 mm) (P = .046). There were no significant differences between the groups in cyclic elongation or linear stiffness during cyclic loading. Primary modes of failure were a type 2 tendon tear with medial tendon disruption in the TOE group (7/10) and a type 1 tendon tear with lateral tendon disruption in the AT group (6/10). Conclusion: TOE repair resulted in a significantly higher mean failure load compared with AT repair in a cadaveric model. The most common modes of failure were a type 2 tendon tear in the TOE group and a type 1 tendon tear in the AT group. Clinical Relevance: A higher mean failure load in TOE versus AT constructs may come at the cost of a less favorable failure mode adjacent to medial anchors at the musculotendinous junction, potentially making revision difficult.
引用
收藏
页码:2364 / 2371
页数:8
相关论文
共 50 条
  • [21] Influence of Rotator Cuff Tear Size and Repair Technique on the Creation and Management of Dog Ear Deformities in a Transosseous-Equivalent Rotator Cuff Repair Model
    Redler, Lauren H.
    Byram, Ian R.
    Luchetti, Timothy J.
    Tsui, Ying Lai
    Moen, Todd C.
    Gardner, Thomas R.
    Ahmad, Christopher S.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2014, 2 (04):
  • [22] Arthroscopic Transosseous Rotator Cuff Repair
    Tross, Anna-Katharina
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2019, 14 (01): : 72 - 72
  • [23] Arthroscopic Transosseous Rotator Cuff Repair
    Stenson, James
    Sanders, Brett
    Lazarus, Mark
    Austin, Luke
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2023, 31 (07) : E366 - E375
  • [24] A Laboratory Comparison of a New Arthroscopic Transosseous Rotator Cuff Repair to a Double Row Transosseous Equivalent Rotator Cuff Repair Using Suture Anchors
    Kummer, Frederick J.
    Hahn, Michael
    Day, Michael
    Meislin, Robert J.
    Jazrawi, Laith M.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2013, 71 (02): : 128 - 131
  • [25] Arthroscopic transosseous rotator cuff repair
    Kim, Kyung-Cheon
    Rhee, Kwang-Jin
    Shin, Hyun-Dae
    Kim, Young-Mo
    ORTHOPEDICS, 2008, 31 (04) : 327 - 330
  • [26] Biomechanical evaluation of four different transosseous-equivalent/suture bridge rotator cuff repairs
    Michael Maguire
    Jerome Goldberg
    Desmond Bokor
    Nicky Bertollo
    Matthew Henry Pelletier
    Wade Harper
    William R. Walsh
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 1582 - 1587
  • [27] Arthroscopic Transosseous Anchorless Rotator Cuff Repair Using the X-Box Technique
    Steinitz, Amir
    Buxbaumer, Peter
    Hackl, Michael
    Buess, Eduard
    ARTHROSCOPY TECHNIQUES, 2019, 8 (02): : E175 - E181
  • [28] Biomechanical evaluation of four different transosseous-equivalent/suture bridge rotator cuff repairs
    Maguire, Michael
    Goldberg, Jerome
    Bokor, Desmond
    Bertollo, Nicky
    Pelletier, Matthew Henry
    Harper, Wade
    Walsh, William R.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (09) : 1582 - 1587
  • [29] A Biomechanical Analysis of Point of Failure During Lateral-Row Tensioning in Transosseous-Equivalent Rotator Cuff Repair
    Dierckman, Brian D.
    Goldstein, Jordan L.
    Hammond, Kyle E.
    Karas, Spero G.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (01): : 52 - 58
  • [30] Shoulder abduction diminishes self-reinforcement in transosseous-equivalent rotator cuff repair in both knotted and knotless techniques
    Smith, Geoffrey C. S.
    Lam, Patrick H.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (12) : 3818 - 3825