Real-time cancer detection with an integrated lensless fluorescence contact imager

被引:10
|
作者
Papageorgiou, Efthymios P. [1 ]
Zhang, Hui [2 ]
Giverts, Simeon [1 ]
Park, Catherine [2 ]
Boser, Bernhard E. [1 ]
Anwar, Mekhail [2 ]
机构
[1] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Berkeley, CA 94720 USA
[2] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94158 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2018年 / 9卷 / 08期
关键词
BREAST-CONSERVING SURGERY; NEAR-INFRARED FLUORESCENCE; POSITIVE SURGICAL MARGINS; IN-VIVO; RADICAL PROSTATECTOMY; SPECTROSCOPIC DEVICE; AMERICAN SOCIETY; ANTIBODY; CONSERVATION; PROBE;
D O I
10.1364/BOE.9.003607
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microscopic tumor cell foci left in a patient after surgery significantly increase the chance of cancer recurrence. However, fluorescence microscopes used for intraoperative navigation lack the necessary sensitivity for imaging microscopic disease and are too bulky to maneuver within the resection cavity. We have developed a scalable chip-scale fluorescence contact imager for detecting microscopic cancer in vivo and in real-time. The imager has been characterized under simulated in vivo conditions using ex vivo samples, providing strong evidence that our device can be used in vivo. Angle-selective gratings enhance the resolution of the imager without impacting its physical size. We demonstrate detection of cancer cell clusters containing as few as 25 HCC1569 breast cancer cells and 400 LNCaP prostate cancer cells with integration times of only 50 ms and 70 ms, respectively. A cell cluster recognition algorithm is used to achieve both a sensitivity and specificity of 92 % for HCC1569 cell samples, indicating the reliability of the imager. The signal-to-noise ratio (SNR) degradation with increased separation is only 1.5 dB at 250 mu m. Blood scattering and absorption reduce the SNR by less than 2 dB for typical concentrations. Moreover, HER2+ breast cancer tissue taken from a patient is distinguished from normal breast tissue with an integration time of only 75 ms. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:3607 / 3623
页数:17
相关论文
共 50 条
  • [41] BitoBody: Real-time human contact detection and dynamic projection system
    Wu, Erwin
    Piekenbrock, Mistki
    Koike, Hideki
    PROCEEDINGS OF THE 10TH AUGMENTED HUMAN INTERNATIONAL CONFERENCE 2019 (AH2019), 2019,
  • [42] Real-time telomerase activity measurements for detection of cancer
    Jakupciak, JP
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2005, 5 (05) : 745 - 753
  • [43] Real-time detection of breast cancer at the cellular level
    Carver, Gary E.
    Locknar, Sarah A.
    Weaver, Donald L.
    Stein, Janet L.
    Stein, Gary S.
    JOURNAL OF CELLULAR PHYSIOLOGY, 2019, 234 (05) : 5413 - 5419
  • [44] NOVEL ROBOTIC REAL-TIME TARGETED NEAR INFRARED FLUORESCENCE DETECTION IN A MOUSE MODEL OF PROSTATE CANCER
    Laydner, Humberto Kern
    Autorino, Riccardo
    Huang, Steve S.
    Heston, Warren D.
    Isac, Wahib
    Khanna, Rakesh
    White, Michael A.
    Spana, Gregory
    Hillyer, Shahab
    Yakoubi, Rachid
    Guillotreau, Julien
    Haber, Georges-Pascal
    Kaouk, Jihad H.
    Stein, Robert J.
    JOURNAL OF ENDOUROLOGY, 2011, 25 : A193 - A193
  • [45] Real-time Detection for Multiple Occupancy and Near Real-time Hogging Detection
    Huy, Nguyen Huy Hoang
    Balan, Rajesh Krishna
    Lee, Youngki
    SenSys'15: Proceedings of the 13th ACM Conference on Embedded Networked Sensor Systems, 2015, : 477 - 478
  • [46] Real-time detection of natural objects using AM-Coded spectral matching imager
    Kimachi, A
    Color Imaging X: Processing, Hardcopy, and Applications, 2005, : 76 - 83
  • [47] Real-time anomaly detection method for space imager streaming data based on HTM algorithm
    Song, Lei
    Liang, Haoran
    Zheng, Taisheng
    201919TH IEEE INTERNATIONAL SYMPOSIUM ON HIGH ASSURANCE SYSTEMS ENGINEERING (HASE 2019), 2019, : 33 - 38
  • [48] A Compact Mid-Wave Infrared Imager System With Real-Time Target Detection and Tracking
    Deng, Xuan
    Wang, Yueming
    He, Daogang
    Han, Guicheng
    Xue, Tianru
    Hao, Yifan
    Zhuang, Xiaoqiong
    Liu, Jun
    Zhang, Changxing
    Wang, Shengwei
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2022, 15 : 6069 - 6085
  • [49] Miniaturized Real-Time Oxygen Detection Systems Integrated with Optical Fiber by Doping Ru-Based Fluorescence Sensors
    Fang, Hon-Ming
    Huang, Song-Jeng
    Yang, Chin-Lung
    Young, Kung-Chia
    Yu, Cheng-Kai
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2013, 33 (01) : 117 - 123
  • [50] An integrated system for real-time detection of stiff masses with a single compression
    Fahmy, Ahmed S.
    Krieger, Axel
    Osman, Nael F.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (07) : 1286 - 1293