Real-time cancer detection with an integrated lensless fluorescence contact imager

被引:10
|
作者
Papageorgiou, Efthymios P. [1 ]
Zhang, Hui [2 ]
Giverts, Simeon [1 ]
Park, Catherine [2 ]
Boser, Bernhard E. [1 ]
Anwar, Mekhail [2 ]
机构
[1] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Berkeley, CA 94720 USA
[2] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94158 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2018年 / 9卷 / 08期
关键词
BREAST-CONSERVING SURGERY; NEAR-INFRARED FLUORESCENCE; POSITIVE SURGICAL MARGINS; IN-VIVO; RADICAL PROSTATECTOMY; SPECTROSCOPIC DEVICE; AMERICAN SOCIETY; ANTIBODY; CONSERVATION; PROBE;
D O I
10.1364/BOE.9.003607
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microscopic tumor cell foci left in a patient after surgery significantly increase the chance of cancer recurrence. However, fluorescence microscopes used for intraoperative navigation lack the necessary sensitivity for imaging microscopic disease and are too bulky to maneuver within the resection cavity. We have developed a scalable chip-scale fluorescence contact imager for detecting microscopic cancer in vivo and in real-time. The imager has been characterized under simulated in vivo conditions using ex vivo samples, providing strong evidence that our device can be used in vivo. Angle-selective gratings enhance the resolution of the imager without impacting its physical size. We demonstrate detection of cancer cell clusters containing as few as 25 HCC1569 breast cancer cells and 400 LNCaP prostate cancer cells with integration times of only 50 ms and 70 ms, respectively. A cell cluster recognition algorithm is used to achieve both a sensitivity and specificity of 92 % for HCC1569 cell samples, indicating the reliability of the imager. The signal-to-noise ratio (SNR) degradation with increased separation is only 1.5 dB at 250 mu m. Blood scattering and absorption reduce the SNR by less than 2 dB for typical concentrations. Moreover, HER2+ breast cancer tissue taken from a patient is distinguished from normal breast tissue with an integration time of only 75 ms. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:3607 / 3623
页数:17
相关论文
共 50 条
  • [11] Performance Estimation of a Real-Time Rosette Imager
    Stoltz, Gene
    Stoltz, Marnus
    ELECTRO-OPTICAL AND INFRARED SYSTEMS: TECHNOLOGY AND APPLICATIONS XVII, 2020, 11537
  • [12] Real-Time Elastography for the Detection of Prostate Cancer
    Georg Salomon
    Jonas Schiffmann
    Current Urology Reports, 2014, 15
  • [13] Real-Time Elastography for the Detection of Prostate Cancer
    Salomon, Georg
    Schiffmann, Jonas
    CURRENT UROLOGY REPORTS, 2014, 15 (03)
  • [14] Real-time elastography for prostate cancer detection
    Klauser, A
    Frauscher, F
    Koppelstaetter, F
    Berger, AP
    Horninger, W
    Bartsch, G
    JOURNAL OF UROLOGY, 2004, 171 (04): : 477 - 477
  • [15] Real-time fluorescence detection of protein transduction into live cells
    Lee, Ya-Jung
    Datta, Silpi
    Pellois, Jean-Philippe
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (08) : 2398 - 2399
  • [16] The detection of HBV DNA by real-time fluorescence quantitative PCR
    Yuan, Y.
    Zhou, X.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A157 - A157
  • [17] Towards fluorescence anisotropy detection for real-time PCR assays
    Crane, B
    Sudo, H
    Thilly, WG
    Hunter, IW
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3060 - 3063
  • [18] Near real-time beryllium detection based on fluorescence.
    McCleskey, TM
    Burrell, AK
    Ehler, DS
    John, K
    Collis, G
    Minogue, E
    Sauer, NN
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 227 : U96 - U96
  • [19] Real-Time Detection of Formaldehyde by a Fluorescence-Based Sensor
    Descamps, M. N.
    Bordy, T.
    Hue, J.
    Mariano, S.
    Nonglaton, G.
    Schultz, E.
    Tran-Thi, T. H.
    Vignoud-Despond, S.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 1009 - 1012
  • [20] A fluorescence detection optical system for real-time quantitative PCR
    Ma Yu-tonga
    Zeng Liang
    Zhang Jian-huan
    OPTICAL DESIGN AND TESTING X, 2020, 11548