Real-time cancer detection with an integrated lensless fluorescence contact imager

被引:10
|
作者
Papageorgiou, Efthymios P. [1 ]
Zhang, Hui [2 ]
Giverts, Simeon [1 ]
Park, Catherine [2 ]
Boser, Bernhard E. [1 ]
Anwar, Mekhail [2 ]
机构
[1] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Berkeley, CA 94720 USA
[2] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94158 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2018年 / 9卷 / 08期
关键词
BREAST-CONSERVING SURGERY; NEAR-INFRARED FLUORESCENCE; POSITIVE SURGICAL MARGINS; IN-VIVO; RADICAL PROSTATECTOMY; SPECTROSCOPIC DEVICE; AMERICAN SOCIETY; ANTIBODY; CONSERVATION; PROBE;
D O I
10.1364/BOE.9.003607
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microscopic tumor cell foci left in a patient after surgery significantly increase the chance of cancer recurrence. However, fluorescence microscopes used for intraoperative navigation lack the necessary sensitivity for imaging microscopic disease and are too bulky to maneuver within the resection cavity. We have developed a scalable chip-scale fluorescence contact imager for detecting microscopic cancer in vivo and in real-time. The imager has been characterized under simulated in vivo conditions using ex vivo samples, providing strong evidence that our device can be used in vivo. Angle-selective gratings enhance the resolution of the imager without impacting its physical size. We demonstrate detection of cancer cell clusters containing as few as 25 HCC1569 breast cancer cells and 400 LNCaP prostate cancer cells with integration times of only 50 ms and 70 ms, respectively. A cell cluster recognition algorithm is used to achieve both a sensitivity and specificity of 92 % for HCC1569 cell samples, indicating the reliability of the imager. The signal-to-noise ratio (SNR) degradation with increased separation is only 1.5 dB at 250 mu m. Blood scattering and absorption reduce the SNR by less than 2 dB for typical concentrations. Moreover, HER2+ breast cancer tissue taken from a patient is distinguished from normal breast tissue with an integration time of only 75 ms. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:3607 / 3623
页数:17
相关论文
共 50 条
  • [1] Real-time fluorescence detection of exoribonucleases
    Sinturel, Flore
    Pellegrini, Olivier
    Xiang, Song
    Tong, Liang
    Condon, Ciaran
    Benard, Lionel
    RNA, 2009, 15 (11) : 2057 - 2062
  • [2] A Real-Time Terahertz Wave Imager
    Xu, Jingzhou
    Cho, Gyu C.
    2008 CONFERENCE ON LASERS AND ELECTRO-OPTICS & QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE, VOLS 1-9, 2008, : 1105 - 1106
  • [3] Real-time endoscopic fluorescence imaging for early cancer detection in the gastrointestinal tract
    Zeng, HS
    Weiss, A
    Cline, R
    MacAulay, CE
    BIOIMAGING, 1998, 6 (04) : 151 - 165
  • [4] Real-time fluorescence detection of a single DNA molecule
    Lockey, C
    Otto, E
    Long, ZF
    BIOTECHNIQUES, 1998, 24 (05) : 744 - 746
  • [5] ECoGScope: An integrated platform for real-time Electrophysiology and fluorescence imaging
    Eun, Jonghee
    Kim, Jeongseop
    Kim, Tae-Eun
    Koo, Ja Wook
    Chou, Namsun
    BIOSENSORS & BIOELECTRONICS, 2025, 274
  • [6] Indoor Real-Time Passive Millimeter Wave Imager For Concealed Threats Detection
    Kpre, Ettien
    Vellas, Nicolas
    Gaquiere, Christophe
    Martins, Alexandre
    Dons, Michael
    Egret, Matthieu
    Werquin, Matthieu
    Jonniau, Sylvain
    Lahaye, Theo
    PASSIVE AND ACTIVE MILLIMETERWAVE IMAGING XXIII, 2020, 11411
  • [7] Subpixel real-time jitter detection algorithm and implementation for polarimetric and helioseismic imager
    Roma, David
    Carmona, Manuel
    Bosch, Jose
    Casas, Albert
    Herms, Atila
    Lopez, Manel
    Ruiz, Oscar
    Sabater, Josep
    Berkefeld, Thomas
    Maue, Thorsten
    Nakai, Eiji
    Schmidt, Wolfgang
    Soltau, Dirk
    Volkmer, Reiner
    Gomez, Jose M.
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2019, 5 (03)
  • [8] Real-time fluorescence imaging system for cancer diagnostics
    Sokolov, VV
    Chissov, VI
    Fabelinsky, VI
    Smirnov, VV
    Zharkova, NN
    BIOMEDICAL OPTOELECTRONICS IN CLINICAL CHEMISTRY AND BIOTECHNOLOGY, PROCEEDINGS OF, 1996, 2629 : 271 - 274
  • [9] Design and implementation of a real-time positron imager
    Naik, PS
    Beling, CD
    Fung, S
    REAL-TIME IMAGING VIII, 2004, 5297 : 294 - 298
  • [10] Low Light CMOS Contact Imager with an Integrated Poly-Acrylic Emission Filter for Fluorescence Detection
    Dattner, Yonathan
    Yadid-Pecht, Orly