Experimental studies on the effect of impeller width on centrifugal compressor stage performance with low solidity vaned diffusers

被引:11
|
作者
Reddy, T. Ch Siva
Murty, G. V. Ramana [1 ]
Prasad, M. V. S. S. S. M.
Reddy, D. N.
机构
[1] Bharat Heavy Elect Ltd, Corp R&D Div, Turbomachinery Lab, Hyderabad 500093, Andhra Pradesh, India
[2] Streenidhi Inst Sci & Technol, Hyderabad, Andhra Pradesh, India
关键词
centrifugal compressor; vaneless diffuser; low solidity vaned diffuser; impeller width; setting angle; performance; flow coefficient; static pressure recovery coefficient;
D O I
10.1243/09576509JPE373
中图分类号
O414.1 [热力学];
学科分类号
摘要
In an effort to improve the performance of centrifugal compressors, detailed studies were carried out on three different impeller-diffuser configurations covering a wide range of design flow coefficients. These were two-dimensional impellers chosen from a multi-stage compressor series with identical blade geometry. The impeller exit widths covered were 24.5, 18.5, and 11.5 mm, respectively. Extensive experimental studies have been carried out on the chosen stage configurations with parallel walled vaneless diffusers (VLDs) as well as low solidity vaned diffuser (LSD). For all the tested configurations, the aerofoil shape of the diffuser vanes remained same while the diffuser width, setting angle, and solidity were chosen as variables. The performance for each of the stages with LSDs was compared with that of the corresponding VLD. Significant improvement in performance in terms of polytropic efficiency, head coefficient, and static pressure recovery coefficient was observed with LSD vanes as compared with the VLD. Significant improvement in performance was noticed from low flow till design point for all the tested cases. The study revealed that among the tested configurations, there is an optimum width at impeller exit and diffuser for which the performance of the stage was the best. Performance in terms of static pressure recovery coefficient was also evaluated for all the tested configurations and compared. All the studies were conducted for solidity ratio of 0.81. The effect of setting angle on wall static pressure coefficient was also studied at 24 degrees and 28 degrees for the flow coefficients corresponding to 80, 100, and 120 per cent of design flow. Flow surveys at impeller exit for the three cases covering impellers/parallel walled diffusers of different widths have also been carried out to know the flow behaviour in the passage between the impeller and the diffuser.
引用
收藏
页码:519 / 533
页数:15
相关论文
共 50 条
  • [1] Some studies on low solidity vaned diffusers of a centrifugal compressor stage
    Siva, Reddy T. Ch.
    Prasad, Mukkavilli
    Ramana, Murty G. V.
    Reddy, D. N.
    PROCEEDINGS OF THE ASME TURBO EXPO 2005, VOL 6, PTS A AND B, 2005, : 917 - 925
  • [2] The effect of low-solidity vaned diffusers on the performance of a turbocharger compressor
    Eynon, PA
    Whitfield, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 1997, 211 (05) : 325 - 339
  • [3] The effect of low-solidity vaned diffusers on the performance of a turbocharger compressor
    School of Mechanical Engineering, University of Bath, United Kingdom
    Proc Inst Mech Eng Part C, 5 C5 (325-339):
  • [4] Effect of the setting angle of a low-solidity vaned diffuser on the performance of a centrifugal compressor stage
    Reddy, TCS
    Murty, GVR
    Mukkavilli, P
    Reddy, DN
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2004, 218 (A8) : 637 - 646
  • [5] Numerical Investigation of the Centrifugal Compressor Stability Improvement by Half Vaned Low Solidity Diffusers
    Siyue Chen
    Shuguang Zuo
    Kaijun Wei
    Journal of Thermal Science, 2021, 30 : 696 - 706
  • [6] Numerical Investigation of the Centrifugal Compressor Stability Improvement by Half Vaned Low Solidity Diffusers
    CHEN Siyue
    ZUO Shuguang
    WEI Kaijun
    Journal of Thermal Science, 2021, 30 (02) : 696 - 706
  • [7] Numerical Investigation of the Centrifugal Compressor Stability Improvement by Half Vaned Low Solidity Diffusers
    Chen, Siyue
    Zuo, Shuguang
    Wei, Kaijun
    JOURNAL OF THERMAL SCIENCE, 2021, 30 (02) : 696 - 706
  • [8] EXPERIMENTAL STUDY OF VANED DIFFUSERS IN CENTRIFUGAL COMPRESSOR
    Jaatinen, Ahti
    Gronman, Aki-Pekka
    Turunen-Saaresti, Teemu
    Backman, Jari
    PROCEEDINGS OF THE ASME TURBO EXPO 2010: TURBOMACHINERY: AXIAL FLOW FAN AND COMPRESSOR AERODYNAMICS DESIGN METHODS, AND CFD MODELING FOR TURBOMACHINERY, VOL 7, PTS A-C, 2010, : 1983 - 1995
  • [9] Effect of high negative incidence on the performance of a centrifugal compressor stage with conventional vaned diffusers
    Ahti Jaatinen
    Aki Grönman
    Teemu Turunen-Saaresti
    Jari Backman
    Journal of Thermal Science, 2011, 20 : 97 - 105
  • [10] Performance improvement of a centrifugal compressor stage by using different vaned diffusers
    Zhang, Y. C.
    Kong, X. Z.
    Li, F.
    Sun, W.
    Chen, Q. G.
    6TH INTERNATIONAL CONFERENCE ON PUMPS AND FANS WITH COMPRESSORS AND WIND TURBINES (ICPF2013), 2013, 52